• Title/Summary/Keyword: INTRA

Search Result 4,106, Processing Time 0.041 seconds

A Fast Intra-Prediction Method in HEVC Using Rate-Distortion Estimation Based on Hadamard Transform

  • Kim, Younhee;Jun, DongSan;Jung, Soon-Heung;Choi, Jin Soo;Kim, Jinwoong
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.270-280
    • /
    • 2013
  • A fast intra-prediction method is proposed for High Efficiency Video Coding (HEVC) using a fast intra-mode decision and fast coding unit (CU) size decision. HEVC supports very sophisticated intra modes and a recursive quadtree-based CU structure. To provide a high coding efficiency, the mode and CU size are selected in a rate-distortion optimized manner. This causes a high computational complexity in the encoder, and, for practical applications, the complexity should be significantly reduced. In this paper, among the many predefined modes, the intra-prediction mode is chosen without rate-distortion optimization processes, instead using the difference between the minimum and second minimum of the rate-distortion cost estimation based on the Hadamard transform. The experiment results show that the proposed method achieves a 49.04% reduction in the intra-prediction time and a 32.74% reduction in the total encoding time with a nearly similar coding performance to that of HEVC test model 2.1.

Effectiveness of Intra-anal Biofeedback and Electrical Stimulation in the Treatment of Children With Refractory Monosymptomatic Nocturnal Enuresis: A Comparative Randomized Controlled Trial

  • Abd El-Moghny, Seham Mohammed;El-Din, Manal Salah;El Shemy, Samah Attia
    • International Neurourology Journal
    • /
    • v.22 no.4
    • /
    • pp.295-304
    • /
    • 2018
  • Purpose: To compare the effects of intra-anal biofeedback (BF) and intra-anal electrical stimulation (ES) on pelvic floor muscles (PFMs) activity, nocturnal bladder capacity, and frequency of wet night episodes in children with refractory primary monosymptomatic nocturnal enuresis (PMNE). Methods: Ninety children of both sexes aged 8-12 years with refractory PMNE participated in this study. They were randomly assigned to 3 groups of equal number: control group (CON) that underwent behavioral therapy and PFM training, and 2 study groups (BF and ES) that underwent the same program in addition to intra-anal BF training and intra-anal ES, respectively. PFMs activity was assessed using electromyography, nocturnal bladder capacity was evaluated by measuring the first morning voided volume, and a nocturnal enuresis diary was used for documenting wet night episodes before treatment and after 3 months of treatment. Results: After training, all groups showed statistically significant improvements in all measured outcomes compared to their pretreatment findings. The ES group showed significantly greater improvements in all measured outcomes than the CON and BF groups. Conclusions: Both intra-anal BF training and ES combined with behavioral therapy and PFMs training were effective in the treatment of PMNE, with intra-anal ES being superior to BF training.

Hardware Design of Intra Prediction Angular Mode Decision for HEVC Encoder (HEVC 부호기를 위한 Intra Prediction Angular 모드 결정 하드웨어 설계)

  • Choi, Jooyong;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.145-148
    • /
    • 2016
  • In this paper, we propose a design of Intra Prediction angular mode decision for high-performance HEVC encoder. Intra Prediction works by performing all 35 modes for efficient encoding. However, in order to process all of the 35 modes, the computational complexity and operational time required are high. Therefore, this paper proposes comparing the difference in the value of the original image pixel, using an algorithm that determines Angular mode efficiently. This new algorithm reduces the Hardware size. The hardware which is proposed was designed using Verilog HDL and was implemented in 65nm technology. Its gate count is 14.9k and operating speed is 2GHz.

  • PDF

Uni-directional 4X4 Intra Prediction Mode for H.264/AVC Coding Efficiency (H.264/AVC에서 성능 향상을 위한 단방향의 4X4 인트라 예측 모드)

  • Jung, Kwang-Su;Park, Sea-Nae;Sim, Dong-Gyu;Lee, Yoon-Jin;Park, Gwang-Hoon;Oh, Seoung-Jun;Jeong, Sey-Yoon;Choi, Jin-Soo
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.815-829
    • /
    • 2010
  • In this paper, we propose a new $4{\times}4$ intra coding method by unidirectional prediction for improvement of intra-frame coding efficiency of H.264/AVC. There are $4{\times}4$, $8{\times}8$, and $16{\times}16$ intra prediction modes in the current H.264/AVC. For the $4{\times}4$ intra prediction, coding efficiency is achieved by accurate prediction with small block size in relatively complicated regions, and the $16{\times}16$ intra prediction method can predict more accurately compared to $4{\times}4$ intra prediction with only one directional information in relatively homogeneous regions. We propose a unidirectional $4{\times}4$ intra prediction method adopting a small-size prediction and one directional prediction approaches. In order to improve coding efficiency, the proposed method is conducted by $4{\times}4$ block and their prediction directions are all the same, resulting that we need to send only one directional information for each macroblock. For intra-frame coding setting, we achieve 10.47% and 1.57% coding efficiency in BD-bitrate for only $16{\times}16$ intra mode and $4{\times}4$, $16{\times}16$ intra mode, respectively.

Intra Prediction Offset Compensation for Improving Video Coding Efficiency (영상 부호화 효율 향상을 위한 화면내 예측 오프셋 보상)

  • Lim, Sung-Chang;Lee, Ha-Hyun;Choi, Hae-Chul;Jeong, Se-Yoon;Kim, Jong-Ho;Choi, Jin-Soo
    • Journal of Broadcast Engineering
    • /
    • v.14 no.6
    • /
    • pp.749-768
    • /
    • 2009
  • In this paper, an intra prediction offset compensation method is proposed to improve intra prediction in H.264/AVC. In H.264/AVC, intra prediction based on various directions improves the coding efficiency by removing spatial correlation between neighboring blocks. In details, neighboring pixels in reconstructed block can be used as intra reference block for the current block to be coded when intra prediction method is used. In order to reduce further the prediction error of the intra reference block, the proposed method introduces an intra prediction offset which is determined in the sense of the rate-distortion optimization and is added to the conventional intra prediction block. Besides the intra prediction offset compensation, the coefficient thresholding method which is used for inter coding in JM 11.0, is used for chroma component in intra block, which leads the improvement of the luma coding efficiency of the proposed method. In experiments, we show that the proposed method achieves average 2.45% in High Profile condition and maximum 4.41% of bitrate reduction relative to JM 11.0.

Adaptive resolution enhancement algorithm using the block size of intra prediction mode (Intra Prediction Mode의 Block Size를 이용한 적응적 해상도 향상 알고리즘)

  • Lee, Si-Mong;Kwon, Yong-Kwang;Won, Chee-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.793-794
    • /
    • 2008
  • The block size of intra prediction mode can differentiate the texture area from the homogeneous area of image. This information can be used to enhance the size resolution of image. Specifically, in this paper, we apply the bicubic interpolation or the bilinear interpolation adaptively selected the intra prediction mode of the H.264 compression.

  • PDF

Intra-Root Cavernous Angioma of the Cauda Equina : A Case Report and Review of the Literature

  • Chun, Sang-Woo;Kim, Sang-Jin;Lee, Tae-Hoon;Koo, Hye-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.4
    • /
    • pp.291-294
    • /
    • 2010
  • Authors experienced intra-root cavernous angioma which is very rare case among cavernous angiomas of cauda equina. Our intra-root cavernous angioma was confirmed by findings from operating field and microscopic examination. We report this case with review of the literature.

Adaptive Coefficient Scanning Based on the Intra Prediction Mode

  • Choi, Byeong-Doo;Kim, Jin-Hyung;Ko, Sung-Jea
    • ETRI Journal
    • /
    • v.29 no.5
    • /
    • pp.694-696
    • /
    • 2007
  • This letter presents an adaptive coefficient scanning method for intra mode coding in H.264. The proposed adaptive scanning uses six alternative scanning orders based on the intra prediction mode. Experimental results show that the proposed method improves the coding efficiency up to 3% compared to conventional scanning methods without additional computations.

  • PDF

Differences of 1-2 Intermetatarsal Angle between Intra-operative nonweight-bearing and Postoperative weight-bearing in Proximal Metatarsal Osteotomy for Hallux Valgus (무지 외반증의 근위 중족골 절골술에 있어서 수술 중 비체중부하와 수술 후 제중부하 방사선 소견에서의 제 1-2 종족골간 각의 차이)

  • Sung, Il-Hoon;Kim, Joo-Hak;Whang, Khun-Sung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2003
  • Purpose: To study the relationship of the 1st to 2nd intermetatarsal angle(1-2 IMA) between the intra-operative and weight bearing postoperative anterior-posterior(AP) radiography, and evaluate the intra-operative predictability for the postoperative 1-2 IMA after proximal metatarsal osteotomy(PMO) in the hallux valgus deformity. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. After the oblique PMO(Ludloff procedure) was performed and the osteotomy site was fixed temporarily, the AP view was taken intra-operatively. About 10 weeks after surgery, postoperative weight bearing AP view was taken. The pre -. intra -, and postoperative 1-2 IMAs were compared and ana lysed statistically. Results: The 1-2 IMAs of the weight bearing preoperative, non-weight bearing intra-operative and weight bearing postoperative AP view were $15.9^{\circ}{\pm}1.8^{\circ},\;4.7^{\circ}{\pm}2.1^{\circ}$, and $6.8^{\circ}{\pm}2.5^{\circ}$ (Mean${\pm}$SD) respectively. The postoperative 1-2 IMA was greater than intra-operative measurement by $2.1^{\circ}{\pm}1.8^{\circ}$ (range; $-1^{\circ}$ to $6^{\circ}$) which was stastistically significant(p<0.05). To get less than $9^{\circ}$ postoperatively as an average normal, intra-operative 1-2 IMA should be within $3.8^{\circ}$ to $5.2^{\circ}$ (95% confidence interval), and intra-operative 1-2 IMA should be within $3.4^{\circ}{\pm}$to $5.4^{\circ}$(95% confidence interval) to get more than $6^{\circ}$ difference between preoperative and postoperative 1-2 IMA, which is regarded as more than average correction by the distal metatarsal osteotomy. Conclusion: In hallux valgus surgery, it should be considered that intra-operative 1-2 IMA was less than the postoperative. To achieve postoperative 1-2 IMA less than $9^{\circ}$ and more than correction angle of $6^{\circ}$, it is suggested that the intra-operative 1-2 IMA should be measured less than about $5^{\circ}$.

  • PDF