• Title/Summary/Keyword: IMRT (intensity modulated radiation therapy)

Search Result 202, Processing Time 0.024 seconds

Simultaneous integrated boost intensity-modulated radiotherapy versus 3-dimensional conformal radiotherapy in preoperative concurrent chemoradiotherapy for locally advanced rectal cancer

  • Bae, Bong Kyung;Kang, Min Kyu;Kim, Jae-Chul;Kim, Mi Young;Choi, Gyu-Seog;Kim, Jong Gwang;Kang, Byung Woog;Kim, Hye Jin;Park, Soo Yeun
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.208-216
    • /
    • 2017
  • Purpose: To evaluate the feasibility of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for preoperative concurrent chemoradiotherapy (PCRT) in locally advanced rectal cancer (LARC), by comparing with 3-dimensional conformal radiotherapy (3D-CRT). Materials and Methods: Patients who were treated with PCRT for LARC from 2015 January to 2016 December were retrospectively enrolled. Total doses of 45 Gy to 50.4 Gy with 3D-CRT or SIB-IMRT were administered concomitantly with 5-fluorouracil plus leucovorin or capecitabine. Surgery was performed 8 weeks after PCRT. Between PCRT and surgery, one cycle of additional chemotherapy was administered. Pathologic tumor responses were compared between SIB-IMRT and 3D-CRT groups. Acute gastrointestinal, genitourinary, hematologic, and skin toxicities were compared between the two groups based on the RTOG toxicity criteria. Results: SIB-IMRT was used in 53 patients, and 3D-CRT in 41 patients. After PCRT, no significant differences were noted in tumor responses, pathologic complete response (9% vs. 7%; p = 1.000), pathologic tumor regression Grade 3 or higher (85% vs. 71%; p = 0.096), and R0 resection (87% vs. 85%; p = 0.843). Grade 2 genitourinary toxicities were significantly lesser in the SIB-IMRT group (8% vs. 24%; p = 0.023), but gastrointestinal toxicities were not different across the two groups. Conclusion: SIB-IMRT showed lower GU toxicity and similar tumor responses when compared with 3D-CRT in PCRT for LARC.

Impact of Respiratory Motion on Breast Cancer Intensity-modulated Radiation Therapy (유방암 세기조절방사선치료에서의 호흡운동 영향)

  • Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.93-97
    • /
    • 2016
  • In this study, we evaluate the effect of respiration on the dose distribution in patient target volume (PTV) during intensity-modulated radiation therapy (IMRT) and research methods to reduce this impact. The dose distributions, homogeneity index (HI), coverage index (CVI), and conformity index of the PTV, which is calculated from the dose-volume histogram (DVH), are compared between the maximum intensity projection (MIP) image-based plan and other images at respiration phases of 30%, 60% and 90%. In addition, the reducing effect of complication caused by patient respiration is estimated in the case of a bolus and the expended PTV on the skin. The HI is increased by approximately twice, and the CVI is relatively decreased without the bolus at other respiration phases. With the bolus and expended PTV, the change in the dose distribution of the PTV is relatively small with patient respiration. Therefore, the usage of the bolus and expended PTV can be considered as one of the methods to improve the accuracy of IMRT in the treatment of breast cancer patients with respiratory motion.

A Monte Carlo Simulation for the Newly Developed Head-and-Neck IMRT Phantom: a Pilot Study (제작된 선량 검증용 IMRT 팬텀의 몬테칼로 시뮬레이션: 예비적 연구)

  • Kang, Sei-Kwon;Cheong, Kwang-Ho;Ju, Ra-Hyeong;Cho, Byung-Chul;Oh, Do-Hoon;Kim, Su-SSan;Kim, Kyoung-Ju;Bae, Hoon-Sik;Han, Young-Yih;Shin, Eun-Hyuk;Park, Sung-Ho;Lim, Chun-Il
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.126-133
    • /
    • 2007
  • A head-and-neck phantom was designed in order to evaluate remotely the quality of the delivery dose of intensity modulated radiation therapy (IMRT) in each institution. The phantom is homogeneous or inhomogeneous by interchanging the phantom material with the substructure like an air or bone plug. Monte Carlo simulations were executed for one beam and three beams to the phantom and compared with ion chamber and thermoluminescent dosimeter (TLD) measurements of which readings were from two independent institutions. For single beam, the ion chamber results and the MC simulations agreed to within about 2% TLDs agreed with the MC results to within 2% or 7% according to which institution read the TLDs. For three beams, the ion chamber results showed -5% maximum discrepancy and those of TLDs were $+2{\sim}+3%$. The accuracy of the TLD leadings should be increased for the remote dose monitoring. MC simulations are a valuable tool to acquire the reliability of the measurements in developing a new phantom.

  • PDF

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Long-term cosmesis following a novel schedule of accelerated partial breast radiation in selected early stage breast cancer: result of a prospective clinical trial

  • Sayan, Mutlay;Hard, Daphne;Wilson, Karen;Nelson, Carl;Gagne, Havaleh;Rubin, Deborah;Heimann, Ruth
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.325-331
    • /
    • 2017
  • Purpose: There is controversy regarding the cosmetic outcome after accelerated partial breast radiation (APBR). We report the cosmetic outcome from a single-arm prospective clinical trial of APBR delivered using intensity-modulated radiation therapy (IMRT) in elderly patients with stage I breast cancer (BC), using a novel fractionation schedule. Materials and Methods: Forty-two patients aged ${\geq}65$, with Stage I BC who underwent breast-conserving surgery were enrolled in a phase I/II study evaluating a 2-week course of APBR. Thirty eligible patients received 40 Gy in 4 Gy daily fractions. Cosmetic outcome was assessed subjectively by physician/patient and objectively by using a computer program (BCCT.core) before APBR, during, and after completion of the treatment. Results: The median age was 72 years, the median tumor size was 0.8 cm, and the median follow-up was 50.5 months. The 5-year locoregional control in this cohort was 97% and overall survival 87%. At the last follow-up, patients and physicians rated cosmesis as 'excellent' or 'good' in 100% and 91 %, respectively. The BCCT.core program scored the cosmesis as 'excellent' or 'good' in 87% of the patients at baseline and 81% at the last follow-up. The median $V_{50}$ (20 Gy) of the whole breast volume (WBV) was 37.2%, with the median WBV $V_{100}$ (40 Gy) of 10.9%. Conclusion: An excellent rate of tumor control was observed in this prospective trial. By using multiple assessment techniques, we are showing acceptable cosmesis, supporting the use of IMRT planned APBR with daily schedule in elderly patients with early stage BC.

Evaluation of Skin Dose of Intensity Modulated Radiation Therapy in Breast Cancer Patients (유방암환자의 세기조절방사선치료에서 피부선량 평가)

  • Kim, Sung-Kyu;Kim, Myung-Se;Yun, Sang-Mo
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.167-171
    • /
    • 2007
  • In the case of radiotherapy following breast conservation therapy for breast cancer patients, the characteristic of skin dose was investigated in the treatment of intensity modulated radiation therapy (IMRT) for breast cancer patients by comparing and analysing entrance skin dose irradiated during radiotherapy using tangential technique radiotherpy, and IMRT. The calculation dose irradiated to breast skin was compared with TLD measurement dose in treatment planning by performing the two methods of radiotherapy using tangential technique, and IMRT in treatment planning equipment. The skin absorbed dose was measured to pass a nipple by spacing of 1 cm distance from center to edge of body. In the radiotherapy of tangential technique, for the irradiation of 180 cGy to PTV, the calculation dose was ranged from 103.5 cGy to 155.2 cGy, measurement dose was ranged from 107.5 cGy to 156.2 cGy, and skin dose in the center was maximum 1.45 times more irradiated than that in the edge. In the IMRT, for the irradiation of 180 cGy to PTV, the calculation dose was ranged 9.8 cGy at 80.2 cGy, measurement dose was ranged 8.9 cGy at 77.2 cGy, and skin dose in the center was maximum 0.23 times less irradiated than that in the edge. IMRT was more effective for skin radiation risks because radiation dose irradiated to skin in IMRT was much less than that in radiotherapy of tangential field technique.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy (Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리)

  • Shim, Su-Jung;Shim, Jang-Bo;Lee, Sang-Hoon;Min, Chul-Kee;Cho, Kwang-Hwan;Shin, Dong-Oh;Choi, Jin-Ho;Park, Sung-Ill;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • For applying the quality assurance (QA) of volumetric modulated arc therapy (VMAT) introduced in Eulji Hospital, we classify it into three different QA steps, treatment planning QA, pretreatment delivering QA, and treatment verifying QA. These steps are based on the existing intensity modulated radiation therapy (IMRT) QA that is currently used in our hospital. In each QA step, the evaluated items that are from QA program are configured and documented. In this study, QA program is not only applied to actual patient treatment, but also evaluated to establish a reference of clinical acceptance in pretreatment delivering QA. As a result, the confidence limits (CLs) in the measurements for the high-dose and low-dose regions are similar to the conventional IMRT level, and the clinical acceptance references in our hospital are determined to be 3 to 5% for the high-dose and the low-dose regions, respectively. Due to the characteristics of VMAT, evaluation of the intensity map was carried out using an ArcCheck device that was able to measure the intensity map in all directions, $360^{\circ}$. With a couple of dosimetric devices, the gamma index was evaluated and analyzed. The results were similar to the result of individual intensity maps in IMRT. Mapcheck, which is a 2-dimensional (2D) array device, was used to display the isodose distributions and gave very excellent local CL results. Thus, in our hospital, the acceptance references used in practical clinical application for the intensity maps of $360^{\circ}$ directions and the coronal isodose distributions were determined to be 93% and 95%, respectively. To reduce arbitrary uncertainties and system errors, we had to evaluate the local CLs by using a phantom and to cooperate with multiple organizations to participate in this evaluation. In addition, we had to evaluate the local CLs by dividing them into different sections about the patient treatment points in practical clinics.

Dosimetric Comparison of Setup Errors in Intensity Modulated Radiation Therapy with Deep Inspiration Breath Holding in Breast Cancer Radiation Therapy (Deep Inspiration Breath Holding을 적용한 유방암 세기변조방사선치료 시 위치잡이오차 분석을 통한 선량 평가)

  • Ham, Il-Sik;Cho, Pyong-Kon;Jung, Kang-Kyo
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.137-143
    • /
    • 2019
  • The aim of this study was analyzed the setup error of breast cancer patients in intensity modulated radiation therapy(IMRT) with deep inspiration breath holding(DIBH) and was analyzed the dose distribution due to setup error. A total of 45 breast cancer cases were performed a retrospective clinical analysis of setup error. In addition, the re-treatment planning was carried by shifting the setup error from the isocenter at the treatment. Based on this, the dose distribution of PTV and OARs was compared and analyzed. The 3D error for small breast group and medium breast group and large breast group were 3.1 mm and 3.7 mm and 4.1 mm, respectively. The difference between the groups was statistically significant(P=0.003). DVH results showed HI, CI for the PTV difference between standard treatment plan and re-treatment plan of 14.4%, 4%. The difference in $D_5$ and $V_{20}$ of the ipsilateral lung was 5.6%, 13% respectively. The difference in $D_5$ and $V_5$ of the heart of right breast cancer patients was 6.8%, 8% respectively. The difference in $D_5$, $V_{20}$ of the heart of left breast cancer patients was 7.2%, 23.5% respectively. In this study, there was a significant association between breast size and significant setup error in breast cancer patients with DIBH. In addition, it was found that the dose distribution of the PTV and OARs varied according to the setup error.

Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향)

  • Hong, Joo-Wan;Jeong, Yun-Ju;Won, Hui-Su;Chang, Nam-Jun;Choi, Ji-Hun;Seok, Jin-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • Purpose: There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1~2 minutes was no signigicant in the dose rate increases. Conclusion: From this study, when the dose rates increase, there was a signigicant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  • PDF