• 제목/요약/키워드: ILI

검색결과 33건 처리시간 0.03초

Unsupervised learning with hierarchical feature selection for DDoS mitigation within the ISP domain

  • Ko, Ili;Chambers, Desmond;Barrett, Enda
    • ETRI Journal
    • /
    • 제41권5호
    • /
    • pp.574-584
    • /
    • 2019
  • A new Mirai variant found recently was equipped with a dynamic update ability, which increases the level of difficulty for DDoS mitigation. Continuous development of 5G technology and an increasing number of Internet of Things (IoT) devices connected to the network pose serious threats to cyber security. Therefore, researchers have tried to develop better DDoS mitigation systems. However, the majority of the existing models provide centralized solutions either by deploying the system with additional servers at the host site, on the cloud, or at third party locations, which may cause latency. Since Internet service providers (ISP) are links between the internet and users, deploying the defense system within the ISP domain is the panacea for delivering an efficient solution. To cope with the dynamic nature of the new DDoS attacks, we utilized an unsupervised artificial neural network to develop a hierarchical two-layered self-organizing map equipped with a twofold feature selection for DDoS mitigation within the ISP domain.

두부방사선사진의 계측오류에 관한 연구 (A STUDY ON THE ERRORS UN THE CEPHALOMETRIC MEASUREMENTS)

  • 나광천;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제28권1호
    • /
    • pp.75-83
    • /
    • 1998
  • 본 연구는 교정 치료를 위한 진단과 치료 계획의 수립에 널리 이용되는 진단 수단의 하나인 두부 방사선 사진을 계측하는 연구에서 볼 수 있는 오류의 중요성을 인식하고, 반복 계측의 방법으로 체계적 오차(systematic error)를 찾아내고 임의적오차(random error)의 범위를 산출하는 과정을 통해 기준점의 식별에 보다 주의가 기울여져야 할 해부학적 기준점들을 찾아보고자 시행되었는데, 통법에 의해 촬영된 100장의 측모 두부 방사선 사진을 연구대상으로 하여 61개의 기준점과 130개의 계측항목을 선정하였고 반복계측을 위해 25개의 표본을 무작위로 선정, 계측오차를 분석하여 다음과 같은 결론을 얻었다. 1. 반복계측에 따른 계측치의 비교에서 130개 전체 계측항목의 18.4%인 24개 항목에서 유의성 있는 차이를 보였다. 2. 반복계측에서 기준점 식별에 차이를 보이는 빈도는 상악 전치의 치근단점(as), 상악골의 최후방벽(tu), 연조직 nasion과 전두정(ft) 그리고 기도의 ad3점에서 매우 높았다. 3. 5%이하의 유의도를 보이는 수준까지 기준점 마킹을 수정한 후, 임의적오차의 범위는 0.67-1.71mm또는 도를 보였다. 4. 가장 임의적오차를 보인 계측항목은 상, 하악 전치가 이루는 각(interincisal angle : ILs-ILi)이었다. 5. 계측 오차의 문제는 주로 해부학적 정의에 대한 정확성의 부족과 불분명한 방사선사진상에 기인되었다. 이상의 연구 결과로 두부 방사선 사진의 계측에는 많은 오류의 가능성이 있음을 확인할 수 있었고 이에 따라 두부방사선 계측에서 뿐 아니라 계측이 이루어지는 모든 연구에서는 항상 계측오류에 대한 분석이 함께 이루어져야 할 것이며, 조사자로서 뿐만 아니라 다른 연구자의 연구결과를 올바르게 인식하기 위한 목적으로도 오류에 대한 인식은 필수적인 것으로 생각된다.

  • PDF

상수도 관망의 유수율 제고 기술의 적용 및 분석 (Technical Application and Analysis for Reduction of Water Loss in Water Distribution Systems)

  • 김주환;이두진;배철호;우형민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.260-266
    • /
    • 2009
  • 본 연구는 지방상수도 배급수 관망의 유수율을 향상시키기 위하여 수량관리를 위한 블록시스템 구축을 통한 구역화 계량, 누수의 정량화를 위한 야간최소유량 측정을 통한 누수평가지표 및 국제 누수지수ILI(Infrastructure Leakage Index)의 도입, 압력제어를 통한 누수저감 효과분석, 장기적인 계획수립을 위하여 노후수도관의 잔존수명 예측 등 누수를 평가 관리할 수 있는 기술을 개발, 제안하였다. N시 야간최소유량 측정을 통하여 주거지역과 상업지역에서 정량적인 누수평가지표로 관길이당, 급수전당의 허용기준누수량을 산정하였다. 이는 관망정비가 완료된 주거, 상업지역을 각각 대상으로 UK water industry에서 제안한 방법을 이용하여 실측을 통한 야간최소유량을 분석함으로써 유수율을 대신할 수 있는 허용누수량 산정식을 개발하였다. 압력제어를 통한 누수저감효과는 감압변의 설치를 통하여 수행되는데, 사천시 우티 배수구역을 대상으로 압력관리 구역을 4개로 분할하고 감압밸브 3개소, 가압펌프 1개소를 설치하여 압력을 조절한 결과 약 $466\;m^3/day$의 누수를 저감시킬 수 있을 것으로 나타나 압력관리를 통하여 연간 113백만의 비용절감효과가 기대되었다. 노후 상수관로의 부식속도 및 잔존수명 예측 연구에서는 매설년도, 토양 또는 수질특성에 따른 관체의 부식속도를 평가함으로써 잔존두께를 예측할 수 있는 모델을 개발하였으며 또한 부식으로 인한 공식특성에 따른 잔존강도 등을 평가할 수 있는 비선형회귀 모형을 개발, 수도관의 잔존수명예측에 활용하여 장단기 노후관 개대체 계획수립에 활용할 수 있도록 제안하였다. 본 연구의 결과들은 지방상수도의 유수율 제고 및 관망정비사업에 적극적으로 활용할 수 있는 누수평가 및 관리기법을 제안할 수 있을 것으로 기대된다.

  • PDF

여러 가지 지표를 이용한 전국도시의 물손실관리 수행능 비교평가 (Performance Evaluation of Water Loss Management in Urban Areas Using Different Performance Indicators)

  • 정신호;유명진;구자용;이화경
    • 대한환경공학회지
    • /
    • 제28권2호
    • /
    • pp.117-127
    • /
    • 2006
  • 최근에 국제물협회(IWA)는 수도서비스분야에 대한 새로운 수행능지표를 제안하였고 이의 성공적인 적용사례가 연이어 보고되고 있다. 이들 보고에 따르면, 특히 급수전당의 물소비량이 크게 차이나는 지역들 간에는 백분율을 이용한 지표를 이용하여 수행능을 비교하지 말아야 한다고 말하고 있다. 그러나 아직까지 한국에서는 백분율을 이용하는 지표들 중의 하나인 유수율이 수도행정의 목표를 수립하기 위해 가장 중점적으로 사용되고 있으며, 시스템간의 물손실관리 수행능을 비교평가 하는 데에 널리 사용되고 있다. 이에 본 연구에서는 전국적인 상수도 및 지역통계 자료를 이용하여 백분율지표의 비합리성을 밝히고 보다 효율적인 물손실관리를 위하여 어떤 것이 보다 바람직한 수행능지표인지를 제안하고자 하였다. 3년간의 상수도 및 지역통계 자료를 이용하여 전국의 도시지역에 대하여 유수율, 실손실율, 1인 당 실손실량, 급수전 당 실손실량, 및 IWA의 누수평가지표(ILI)를 산정하고, 각 대상지역을 비교 평가한 결과에 따르면, 백분율을 이용한 지표 즉, 유수율 및 실손실율은 지역 조건이 크게 차이나는 곳 간의 수행능을 제대로 비교하지 못하는 반면, 급수전 당 실손실량 및 누수평가지표는 수행능을 효율적으로 비교, 평가하는 것으로 나타났다. 또한 유수율이 높게 나타나는 지역에서도 하나의 급수전 당 손실되고 있는 물의 양이 매우 클 수 있다는 것을 보여주었다. 따라서 수도사업자의 물손실 관리에 대한 수행능을 보다 합리적으로 평가하여 물손실 문제에 쉽게 접근하고, 문제를 효율적으로 해결하기 위해서는 급수전 당 실손실량 혹은 누수평가지표를 이용하는 것이 바람직하다고 판단된다.

서로 다른 지연 시간을 갖는 OFDMA 기반의 Wireless Mesh Networks를 위한 신호 검출 기법 (A Signal Detection Technique for OFDMA-based Wireless Mesh Networks with Different Time Delays)

  • 박창환;유현일;김영준;권동승;조용수
    • 한국통신학회논문지
    • /
    • 제35권6C호
    • /
    • pp.495-505
    • /
    • 2010
  • 본 논문에서는 OFDMA(Orthogonal Frequency Division Multiple Access) 기반의 WMN(Wireless Mesh Network)에서 분산 노드(node)간에 NFP(Near-Far Problem)의 영향을 알아보기 위하여, TDoA(Time Difference of Arrival)와 DUR(Desired-to-Undesired power Ratio)의 통계적 특성을 분석한다. WMN에서 서로 다른 지연 시간에 따른 ISI(Inter-Symbol Interference)와 ICI(Inter-Carrier Interference) 및 ILI(Inter Link Interference)의 영향을 극복하기 위하여 각 부반송파 별로 FFT 윈도우 시작 위치에 따른 effective SINR을 유도하고, 이를 바탕으로 각 부반송파 위치에서 BER을 최소화 하는 FFT 윈도우 시작 위치 선정 기법을 제안한다. 또한, 서로 다른 지연 시간을 갖는WMN에서 신호검출을 위하여 ZF-2DOSIC(Zero Forcing - 2 Dimensional Ordered Successive Interference Cancellation) 기법을 제안한다. 제안된 FFT 윈도우 시작 위치 선정 기법과 신호 검출 기법은 기존의 기법과 비교하여 WMN에서 effective SINR과 uncoded BER 성능이 크게 향상되는 것을 모의실험을 통하여 확인한다.

Covalent Linkage of IL-12 and Ovalbumin Confines the Effects of IL-12 to Ovalbumin-specific Immune Responses

  • Kim, Tae-Sung;Hwang, Seung-Yong;Yoo, Gyurng-Soo
    • Archives of Pharmacal Research
    • /
    • 제20권5호
    • /
    • pp.396-403
    • /
    • 1997
  • In order to direct the form of the immune response in an antigen-specific manner, we constructed a fusion protein (OVA/IL12) that contained the T cell-dependent antigen, ovalbumin (OVA), covalently linked to murine interleukin-12 (IL-12). The OVA/IL12 protein was produced in a baculovirus expression system and was purified by anti-OVA immunoaffinity chromatography. The purified OVA/ILI2 protein displayed potent IL-12 bioactivity in an IL-12 proliferation assay. BALB/c mice immunized with the OVA/IL12 protein produced increased quantities of anti-OVA IgG2a antibody compared with mice immunized with recombinant OVA alone. Lymph node cells from the immunized mice with the OVA/IL12 protein produced large amounts of IFN-,Y when restimulated in vitro with OVA, while those from mice immunized with the OVA protein produced little or no IFN-.gamma.. In contrast, immunization with a mixture of OVA and free recombinant IL-12 also induced IFN-.gamma. production, which was not OVA-specific. These studies indicate that the OVA/IL12 fusion protein can induce OVA-specific, Th1-dominated immune responses, and that the covalent linkage of OVA and IL-12 confines the effect of IL-12 to OVA-specific cells.

  • PDF

Implementation of High Magnetization System for Performance Enhancement of Magnetic Flux Leakage Tool

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Kim, Dong-Ku;Park, Dae-Jin;Rho, Yong-Woo;Seo, Kang;Park, Gwan-Soo;Choi, Doo-Hyun;Song, Sung-Jin
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.199-203
    • /
    • 2010
  • This paper discusses the effectiveness of high magnetization saturation in ILI (In-Line Inspection) using an MFL (Magnetic Flux Leakage) tool, and introduces a practical method for improving the magnetization level together with the piggability. Thin steel plates, replacing the conventional wire brushes were used as conductors to transfer the magnetic flux to the pipe wall. The newly designed MFL tool was compared with the conventional version by means of FEM (Finite Element Method) analysis and full-scale experiments. In the results, the newly developed magnetization system obtained a stronger MFL signal amplitude, specially 2.7 times stronger, than that obtained by the conventional magnetization system for the same defect dimensions.

극저온용 스테인레스 강의 저온거동 특성 (Mechanical Characteristics of Stainless Steel under Low Temperature Environment)

  • 홍진한;금동민;한대석;박인범;전민성;고경완;이제명
    • 대한조선학회논문집
    • /
    • 제45권5호
    • /
    • pp.530-537
    • /
    • 2008
  • Austenitic stainless steels(SUS 304, SUS 316), which are used for safety control valve of LNG carrier, are occasionally exposed in the cryogenic environment. In this regards, it is required to evaluate the mechanical characteristics under the low temperature environment. In this study, a series of uniaxial tensile test was carried out varying temperature for austenitic stainless steel. The phenomena of the strain-induced plasticity have been observed on the all temperature ranges. The critical value for threshold of 2nd hardening due to the phase transformation induced plasticity as well as the increase of hardening have been reported. The summarized experimental results would be used for the validation of numerical techniques applicable for the nonlinear hardening behavior of austenitic stainless steel under the cryogenic temperature environment.

소블럭별 평가지표를 이용한 물손실관리 수행능 지표 비교분석 (Analysis of Performance Evaluation of Water Loss Management using Evaluation Index in District Metered Area)

  • 김대웅;장지윤;최예지;장동우
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.423-423
    • /
    • 2021
  • 국내에서는 '물손실(누수)을 얼마나 잘 관리하고 있는지' 평가하는 물손실관리 수행능 지표를 '유수율(누수율)' 로 판단하고 있다. 하지만, 유수율은 실제 관리자의 의지와 무관한 인자에 영향을 받을 수 있으며, 지역의 여건상 유수율이 높게 나올 수밖에 없는 지역이 있는가 하면 반대로 지역의 여건 상 유수율이 낮게 나올 수밖에 없는 지역이 있다. 따라서 유수율만을 이용하여 물손실관리 수행능력을 평가하는 지표로는 미흡함이 있는 것으로 판단될 뿐만 아니라 IWA에서는 전통적인 백분율을 이용한 지표(손실율, 유수율, 무수율 등)의 문제를 언급하면서 수자원의 효율적인 사용 혹은 상수도사업의 경제성을 나타내는 목적 외에는 사용하지 말아야 한다고 권고하였다. 현재까지의 연구를 보면, 국내 실정에 맞는 다양한 물손실관리 수행능 지표들이 언급되면서 이에 대한 적합성 및 적용성에 대한 많은 연구들이 진행되어 왔다. 기존의 연구들은 지자체 단위로 물손실관리 수행능 지표에 대한 연구를 진행하였다면, 본 연구에서는 소블럭 단위로 수도통계자료를 분석하여 물손실관리를 위한 어떠한 지표를 이용하는 것이 타당한 방법인지 제시하고자 하였다. 비교분석을 하기 위한 지표인 소블럭별 유수율, 실손실율(누수율), 1인당 실손실량, 급수전당 실손실량, 누수평가지표(ILI)를 산정하고, 그 결과에 따라 소블럭별 순위를 결정하였다. 유수율과 급수인구를 고려한 1인당 실손실량과의 비교분석에서 높은 R2 (결정계수)값과 소블럭별 순위변동 폭이 적은 것으로 나타났으나, 유수율과 급수전수를 고려한 급수전당 실손실량 및 배수관의 연장과 급수전수, 평균압력을 고려한 누수평가지표와의 비교분석에서는 낮은 R2값과 소블럭별 순위 변동폭이 큰 것으로 나타났다. 앞서 언급한 것처럼, 유수율만을 이용하여 물손실관리 수행능을 설명하기에는 부족할 것으로 판단되며, 유수율 외에도 다양한 지표들을 종합적으로 고려했을 때 가장 바람직한 물손실관리 수행능 평가가 될 것으로 사료된다.

  • PDF

한국인과 스칸디나비아계 백인의 두부자세와 두개안면구조의 형태에 관한 비교연구 (A comparative study on head posture and craniofacial morphology between koreans and scandinavian caucasians)

  • 오용덕;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제29권6호
    • /
    • pp.707-720
    • /
    • 1999
  • 본 연구는 두부자세를 형성하는 두개저와 경추가 이루는 각의 차이가 두개안면구조의 형태에 어떠한 차이로 나타나는지를 파악해 보기 위하여, 51명의 한국인 성인 남자와 120명의 스칸디나비아계 백인, 성인 남자를 대상으로 자연상태의 두부위치로 촬영하여 얻은 두부방사선계측사진에서 두부자세변수, 두개저, 경추, 상악골, 하악골, 상하악 악골관계 그리고 치아, 치조에 관련된 변수를 설정, 이를 서로 비교함으로써 다음과 같은 결과를 얻었다. 1. NSL/OPT로 표현되는 두개와 경추가 이루는 각은 한국인에서 평균 9.28도 더 크게 나타났다. 2. n-s로 표현되는 전두개저의 길이는 한국인에서 평균 4.66 mm가 더 짧게 나타났다. 3. sp-pm 및 ss-pm으로 표현되는 상악골 기저의 길이는 한국인에서 각각 평균 2.75 mm, 4.65 mm더 짧은 양상을 보였으며, n-sp로 표현되는 상악골의 전방부 고경, 그리고 s-pm으로 표현되는 상악골의 후방부 고경은 각각 2.60 mm, 2.06 mm더 긴 양상을 보이는 한편, NSL/NL로 표현되는 상악골의 두개저에 대한 기울기는 차이를 보이지 않았다. 4. pg-tgo로 표현되는 하악골체의 길이와 ar-tgo로 표현되는 하악골지의 고경은 두 표본에서 동일한 양상을 보였으나, ML/RL로 표현되는 하악우각부는 한국인에서 3.22도 작은 양상을 보였고, NSL/ML로 표현되는 두개저에 대한 하악골의 경사도는 한국인에서 2.44도 더 큰 양상을 보였다. 5. s-n-sp 및 s-n-ss로 표현되는 상악골의 두개저에 대한 돌출도, 그리고 s-n-sm으로 표현되는 하악골의 두개저에 대한 돌출도는 차이를 보이지 않았다. 6. ss-n-pg로 표현되는 상,하악골의 전후방적 관계는 한국인에서 1.44도 더 큰 양상을 보였으나. NL/ML로 표현되는 수직적관계는 차이를 보이지 않았다. 7. n-go으로 표현되는 전안면고경은 한국인에서 5.57 mm 더 큰 양상을 보였다. 8. CL/ML로 표현되는 하악치조의 돌출도는 한국인에서 5.71도 더 큰 양상을 보였으며, ILs/ILi로 표현되는 상,하악 전치가 이루는 각은 한국인에서 3.08도 더 작은 양상을 보였다. 이상의 결과는 두개저와 경추가 이루는 두부자세에 따라 두개안면구조의 형태가 영향을 받을 수 있음을 보여주었다.

  • PDF