• Title/Summary/Keyword: IL4R

Search Result 1,526, Processing Time 0.036 seconds

Study on Production Performance of Shale Gas Reservoir using Production Data Analysis (생산자료 분석기법을 이용한 셰일가스정 생산거동 연구)

  • Lee, Sun-Min;Jung, Ji-Hun;Sin, Chang-Hoon;Kwon, Sun-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.58-69
    • /
    • 2013
  • This paper presents production data analysis for two production wells located in the shale gas field, Canada, with the proper analysis method according to each production performance characteristics. In the case A production well, the analysis was performed by applying both time and superposition time because the production history has high variation. Firstly, the flow regimes were classified with a log-log plot, and as a result, only the transient flow was appeared. Then the area of simulated reservoir volume (SRV) analyzed based on flowing material balance plot was calculated to 180 acres of time, and 240 acres of superposition time. And the original gas in place (OGIP) also was estimated to 15, 20 Bscf, respectively. However, as the area of SRV was not analyzed with the boundary dominated flow data, it was regarded as the minimum one. Therefore, the production forecasting was conducted according to variation of b exponent and the area of SRV. As a result, estimated ultimate recovery (EUR) increased 1.2 and 1.4 times respectively depending on b exponent, which was 0.5 and 1. In addition, as the area of SRV increased from 240 to 360 acres, EUR increased 1.3 times. In the case B production well, the formation compressibility and permeability depending on the overburden were applied to the analysis of the overpressured reservoir. In comparison of the case that applied geomechanical factors and the case that did not, the area of SRV was increased 1.4 times, OGIP was increased 1.5 times respectively. As a result of analysis, the prediction of future productivity including OGIP and EUR may be quite different depending on the analysis method. Thus, it was found that proper analysis methods, such as pseudo-time, superposition time, geomechanical factors, need to be applied depending on the production data to gain accurate results.

Usefulness of Serum Thymidine Kinase 1 as a Biomarker for Aggressive Clinical Behavior in B-cell Lymphoma (B세포림프종의 임상적 악성도 표지자로서 혈청 Thymidine Kinase 1의 유용성)

  • Kim, Heyjin;Kang, Hye Jin;Lee, Jin Kyung;Hong, Young Jun;Hong, Seok-Il;Chang, Yoon Hwan
    • Laboratory Medicine Online
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • Background: The cell cycle-dependent enzyme thymidine kinase 1 (TK1) is known to increase during cancer cell proliferation and has been reported as a prognostic marker for various hematologic malignancies and solid tumors. This study aimed to determine the reference interval in Korean healthy controls and to evaluate the usefulness of TK1 as a biomarker for aggressive clinical behavior in B-cell lymphoma patients. Methods: We enrolled 72 previously untreated patients with B-cell lymphoma and 143 healthy controls. Serum TK1 levels were measured by chemiluminescence immunoassay ($Liaison^{(R)}$, DiaSorin, USA). We established the reference intervals in healthy controls. The diagnostic performance of serum TK1 was studied using receiver operating characteristic (ROC) analysis, and the correlation between the cutoff level for serum TK1 and clinical characteristics of B-cell lymphoma was evaluated. Results: The reference range (95th percentile) of serum TK1 in healthy controls was 5.4-21.8 U/L. There was a clear difference in TK1 levels between patients with B-cell lymphoma and healthy controls ($40.6{\pm}68.5$ vs. $11.8{\pm}4.4U/L$, P <0.001). The area under the curve of serum TK1 for the diagnosis of B-cell lymphoma was 0.73 (cutoff, 15.2 U/L; sensitivity, 59.7%; specificity, 83.2%). An increased TK1 level (${\geq}15.2U/L$) correlated with the advanced clinical stage (P <0.001), bone marrow involvement (P =0.013), international prognostic index score (P =0.001), lactate dehydrogenase level (P =0.001), low Hb level (<12 g/dL) (P =0.028), and lymphocyte count (P =0.023). Conclusions: The serum TK1 level could serve as a useful biomarker for aggressive clinical behavior in B-cell lymphoma patients.

MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING (Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교)

  • Kang, Suk-Ho;Kim, Oh-Young;Oh, Myung-Hwan;Cho, Byeong-Hoon;Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).

The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam (6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Choi, Jin-Ho;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • The standard dosimetry systems based on an absorbed dose to water recommend to use a planeparallel chamber for the calibration of such a low-megavoltage electron beam as a nominal energy of 6 MeV. For this energy ranges of an electron beam a cylindrical chamber should not be used for the routinely regular beam calibration, but the feasibility of the temporary use of a cylindrical chamber was studied to give temporary solutions for special situations users meet. The PTW30013 chambers and the electron beam quality of $R_{50}=2.25\;g/cm^2$ were selected for this study. 10 PTW30013 chambers, a cylindrical type of chamber, were calibrated in KFDA, the secondary standards dosimetry laboratories, and given the absorbed dose-to-water calibration factors, respectively. A "temporary" $k_{Q,Q_0}$ for each chamber were calculated using the absorbed dose determined by a cross-calibrated planeparallel chamber, with the result of an average 0.9352 for 10 chambers. This value for PTW30013 chamber was used to determine an absorbed dose to water at the reference depth. The absorbed doses determined by PTW30013 chambers were in an agreement within 2% with that by ROOS chamber. In a certain situation where a cylindrical chamber be used instead of a planeparellel chamber, the value of 0.9352 might be useful to determine an absorbed dose to water in the same beam quality of electron beam as this study.

  • PDF

Correlation between Body Fat Percent Estimated by Bioelectrical Impedance Analysis and Other Variable Methods (생체전기 저항법에 의한 체지방율과 다른 계측치간의 상관성 연구)

  • Yom, Hye Won;Kim, Su Jung;Whang, Il Tae;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.8
    • /
    • pp.751-757
    • /
    • 2003
  • Purpose : Obesity is a significant health problem with medical and psychological consequences for children and adolescents. The purpose of this study was to assess the correlation between body fat percent using bioelectrical impedance(BI) and other variable methods. Methods : We measured height, weight, body mass index(BMI) and body fat percent by skinfold thickness(ST) and BI in 1,035(496 male; 539 female) children from seven to 18 years of age. The correlation coefficients between BI and each of the other different methods were obtained. The sensitivity and specificity to predict obesity by these several methods were studied. Results : Fat percent estimated by BI analysis and BMI showed a strong correlation(r=0.749). Fat percent estimated by BI analysis and ST showed a very strong correlation(r=0.835). At the 95th percentile cut-off point for BI, ST showed a sensitivity of 57.7%, and a specificity of 97.6% for estimating body fat. At the 95th percentile cut-off point for BI, BMI showed a sensitivity of 84.9%, and a specificity of 99.3% for estimating body fat. Conclusion : The fat percent estimated by BI analysis correlated strongly with ST or BMI. BI analysis is an objective and accurate method for estimating body fat in childhood obesity.

CT Simulation Technique for Craniospinal Irradiation in Supine Position (전산화단층촬영모의치료장치를 이용한 배와위 두개척수 방사선치료 계획)

  • Lee, Suk;Kim, Yong-Bae;Kwon, Soo-Il;Chu, Sung-Sil;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.165-171
    • /
    • 2002
  • Purpose : In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. Materials and Method : A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetrie image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was peformed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. Results : CSI in the supine position was successfully peformed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The differences between the DRRs and the portal films were less than 3 mm in the vertebral contour. Conclusion : CSI in the supine position is feasible in patients who cannot lie on prone position, such as pediatric patienta under the age of 4 years, patients with a poor general condition, or patients with a tracheostomy.

A Study on the Differences of Cognitive Functions, Neurobehavioral Symptoms and Daily Living Functions According to the Lateralization of Lesion in Patients with Non-Traumatic Subcortical Cerebrovascular Disease (비외상성 피질하 뇌혈관질환 환자에서 병소의 편측성에 따른 인지기능, 정신행동증상 및 일상생활기능의 차이에 대한 연구)

  • Park, Young-Soo;Lee, Young-Ho;Choi, Young-Hee;Ko, Dae-Kwan;Chung, Young-Cho;Park, Byoung-Kwan;Kim, Soo-Ji;Chung, Suk-Haui;Ko, Byoung-Hee;Song, Il-Byoung;Park, Kun-Woo;Lee, Dae-Hie
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.1
    • /
    • pp.56-67
    • /
    • 1996
  • Objectives : This study was designed to find clinical factors that could be differentiated by the lateralization of lesion and also find clinical factors to predict the lateralization of lesion. Methods : The subjects were 65 cooperative inpatients and outpatients with non-traumatic subcortical cerebrovascular disease without neurologic and psychiatric history from January 1995 to September 1995 ; 48 patients in Kyung Hee University, Oriental Medicine Hospital, 35 patients in Anam Hospital, Korea University were examined as subjects, but authors excluded 20 patients whose data were incomplete or who had uncertain lesions on brain CT or MRI. The 65 patients were divided into three groups-group with left hemispheric lesion, group with right hemispheric lesion, group with both hemispheric lesion-according to the finding of brain imaging study. Their cognitive functions were evaluated by the Benton Neuropsychological Assessment(BNA), their subjective neurobehavioral symptoms by Symptom Check List-90-R(SCL-90-R), their objective neurobehavioral symptoms by Neurobehavioral Rating Scale, and their daily living functions by Geriatric Evaluation by Relative's Rating Instrument(GERRl) and Instrumental Activities of Daily Living Scale(IADLs). Results : The results were as follows : 1) The results of cognitive function test indicated that the group with right hemispheric lesion showed low functions in Tactile Form Perception(left), the group with left hemispheric lesion showed low functions in Finger localization(right), the group with right hemispheric lesion showed low functions in Finger Localization(left). 2) Though, there were little significant differences in subjective neurobehavioral symptoms, the group with right hemispheric lesion showed higher scores in all symptoms except hostility. 3) Though, there were little significant differences in objective neurobehavioral symptoms, the group with both hemispheric lesion showed higher scores in cognition, guilty/disinhibition, the group with left hemispheric lesion showed higher scores in lability of mood, the group with right hemispheric lesion showed highest scores in psychotism, neurotism, agitation-hostility and decreased motivation/emotional withdrawal. 4) There were little significant differences among three groups in Daily Living Functions, but the group with right hemispheric lesion showed the lowest functions in Instrumental Activities of Daily Living. 5) As a result of discriminant analysis on each factor's contribution to the prediction of lesion, Finger Localization(left), Phoneme Discrimination and Tactile Form Perception(right) showed that they had the potentiality to predict lesion. Conclusion : The results suggest that there are little significant differences among the groups of three non-traumatic subcortical cerebrovascular disease in cognitive functions, but the group with right hemispheric lesion showed more serious and various changes in subjective and objective neurobehavioral symptoms, and showed low functions in Instrumental Activities of Daily Living. This results suggest the possibility that the decline of the daily living function in the group with right hemispheric lesion were due to various symptoms, not due to cognitive dysfunction. The confirmation of the possibility should be worked out through the follow-up study of some groups containing cortical lesion. Apart from these findings, Finger Localization, Tactile Form Perception(right) and Phoneme Discrimination suggest that they can be used as clinically valuable cognitive parameters that predict the lateralization of lesion in non-traumatic cerebrovascular disease.

  • PDF

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.

Establishment of Sample Preparation Method to Enhance Recovery of Food-borne Pathogens from Produce (농산물 중 식중독세균 검출을 위한 전처리법 확립)

  • Kim, Se-Ri;Choi, Song-Yi;Seo, Min-Kyoung;Lee, Ji-Young;Kim, Won-Il;Yoon, Yohan;Ryu, Kyoung Yul;Yun, Jong-Cul;Kim, Byung-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.279-285
    • /
    • 2013
  • To establish sample preparation method for detection of food-borne pathogens from lettuce, perilla leaves, cucumber, pepper, and cherry tomato, the influences of diluent composition, processing time, and proportion of diluent to sample were examined. Each produce was inoculated with 6.0 log $CFU/cm^2$ of Escherichia coli O157:H7, Salmonella Typhimurium, Listeria monocytogenes, Staphylococcus aureus, and Bacillus cereus. Each produce was treated with 0.1% peptone water, and D/E neutralizing broth. Processing time of produce was 30, 60, 90, and 120s, and the proportion of diluent to sample was 2 : 1, 4 : 1, 9 : 1, and 19 : 1. The number of bacteria after treatment of D/E neutralizing broth was higher than that of 0.1% peptone water (P<0.05). In cherry tomato, the population of S. typhimurium recovered from treated with D/E broth was higher than that recovered from treated with 0.1% peptone water by 1.05 log $CFU/cm^2$ (P<0.05). No difference in numbers of pathogens was observed in processing time. Optimum proportion of diluent to perilla leaf, iceberg lettuce, cucumber, green pepper, and tomato was 9 : 1, 4 : 1, 2 : 1, 2 : 1, and 2 : 1, respectively. These data suggest that D/E neutralizing broth should be recommend as diluent, and the diluent volume applied to produce should be determined in proportion to produce surface area per weight (g).

Varietal Difference of Oil Content and Omega Fatty Acid omposi tion in Korea Local Perilla (들깨 지방수집종의 기름함량 및 오메가 지방산 조성 차이)

  • Ryu, Su-Noh;Lee, Jung-Il;Lee, Hyo-Sung;Park, Chung-Berm;Sung, Byung-Ryeol
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.6
    • /
    • pp.560-565
    • /
    • 1993
  • This study was conducted to obtain basic information for breeding materials on the oil quality improvement of perilla seeds. Oil contents and omega(${\omega}$)fatty acid compositions of seeds were investigated to 317 varieties of domestic perillas. Oil contents of 317 perilla varieties ranged from 35.6 to 55.3 with 44.5% of varietal mean. The major omega fatty acids contained in the oil were oleic acid(${\omega}$-9) 15.2%, linoleic acid(${\omega}$-36) 13.9% and linolenic acid(${\omega}$-3) 63.1% in the mean value. Varietal variation of $\omega$-9, 6 and 3 fatty acids ranged of 9.5~21.4%, 9.1~20.4% and 50.6~70.5% respectively. Unsaturated fatty acid were averaged 92.2% of seed oil in fatty acid composition. The ratios of ${\omega}$-6 to ${\omega}$-3 ranged of 0.13~0.34%(0.22% in mean value). The highest linolenic acid variety was Yecheonjong being 70.5%. The lowest variety in rations of ${\omega}$-6 to ${\omega}$-3 was Goseongjong being 0.13%. Oil content showed positive correlation with stearic acid and linolenic acid, while the negative correlation with oil content and linoleic acid. On the other hand, A significant negative correlation were showed between lionolenic acid and the ratios ${\omega}$-6 / ${\omega}$-3 fatty acid, saturated fatty acid. Saturated fatty acid was highly correlated with unsaturated fatty acid negatively being r=-0.723$^{**}$

  • PDF