• Title/Summary/Keyword: IGBT Inverter

Search Result 306, Processing Time 0.03 seconds

A Comparative Study of Two Diagnostic Methods Based on the Switching Voltage Pattern for IGBT Open-Circuit Faults in Voltage-Source Inverters

  • Wang, Yuxi;Li, Zhan;Xu, Minghui;Ma, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1087-1096
    • /
    • 2016
  • This paper reports an investigation conducted on two diagnostic methods based on the switching voltage pattern of IGBT open-circuit faults in voltage-source inverters (VSIs). One method was based on the bridge arm pole voltage, and the other was based on bridge arm line voltage. With an additional simple circuit, these two diagnostic methods detected and effectively identified single and multiple open-circuit faults of inverter IGBTs. A comparison of the times for the diagnosis and anti-interference features between these two methods is presented. The diagnostic time of both methods was less than 280ns in the best case. The diagnostic time for the method based on the bridge arm pole voltage was less than that of the method based on the bridge arm line voltage and was 1/2 of the fundamental period in the worst case. An experimental study was carried out to show the effectiveness of and the differences between these two methods.

Power Module Bridge Type Auxiliary Resonant AC Link Snubber-Assisted Three-Phase Soft Switching Inverter

  • Hisashi Iyomori;Nagai, Shin-ichiro;Masanobu Yoshida;Eiji Hiraki;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.77-86
    • /
    • 2004
  • This paper presents a novel three-phase power module bridge type auxiliary resonant AC link snubber for the three-phase voltage-fed sinwave soft switching PWM inverter operating under specific instantaneous space voltage vector modulation. The operating principle of this resonant snubber is described for current source load model during one switching period, along with its design approach based on the simulation data. The performance evaluations of space vector modulation three-phase sinewave soft switching inverter with a new three-phase active auxiliary resonant AC link snubber are discussed as compared with those of three-phase voltage source-fed sinewave hard switching PWM inverter with a standard space voltage vector modulation strategy. The power loss analysis and conventional efficiency estimation of three-phase soft switching PWM inverter using ICBT modules are carried out including all the conduction power losses based upon the measured v-i characteristics of IGBT and its antiparallel diode as well as their switching losses.

Compensating for the Neutral-Point Potential Variation in Three-Level Space-Vector PWM Method (3-레벨 인버터 공간벡터 변조시의 중성점 전위 변동 보상법)

  • Seo Jae Hyeong;Kim Kwang Seob;Bang Sang Seok;Choi Chang Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.475-478
    • /
    • 2001
  • In performing the three-level SVPWM, it is nearly impossible to control the neutral-point potential exactly to the half of the dc-link voltage at all times. Therefore the inverter would produce an erroneous output voltage by this voltage unbalance. So the voltage unbalance has to be compensated in doing PWM, when the voltage unbalance occurs whether it is small or large, to make the inverter output voltage follow the reference voltage exactly the same. In this paper, a new compensating method for the neutral-point potential variation in a three-level inverter space vector PWM (SVPWM) is presented. By using the proposed method, the output voltage of the inverter can be made same as the reference voltage and thus the current and torque ripple of the inverter driven motor can be greatly improved even if the voltage unbalance is quite large. The proposed method is verified experimentally with a 3-level IGBT inverter.

  • PDF

Performance Evaluations of Quasi Resonant DC Link Assisted Three Phase Soft Switching Inverter for AC Servo Motor Drive

  • Yoshitsugu J.;Ando M.;Rukonuzzaman M.;Hiraki E.;Nakaoka M.;Inoue K.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.232-235
    • /
    • 2001
  • This paper presents a circuit of the quasi-resonant DC link to achieve soft-switching three phase inverter using intelligent IGBT power module. The soft-switching operation in this circuit is confirmed simulation and experimental results. Its conductive noise is measured for electrical AC motor drive as compared with that of the conventional hard switching inverter.

  • PDF

New Soft-Switching Current Source Inverter for Photovoltaic Power System

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.644-649
    • /
    • 2001
  • This paper proposes a soft-switching current -source inverter for photovoltaic power system, which has an H-type switched-capacitor module composed of two semiconductor switches, two diodes, and an L-C resonant circuit. The operation of proposed system was analyzed by a theoretical approach with equivalent circuits and verified by computer simulations with SPICE and experimental works with a hardware prototype. The proposed system could be effectively applied for the power converter of photovoltaic power system interconnected with the power system.

  • PDF

Vector Controlled Inverter for Elevator Drive (ELEVATOR 구동용 VECTOR 제어 인버터)

  • Shin, H.J.;Jang, S.Y.;Lee, S.J.;Lee, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.627-630
    • /
    • 1991
  • This study is about vector controlled inverter for high quality elevator drive that is to improve the settling accuracy of elevator car and passenger's comfort in commercial buildings. In this study, an instantaneous space vector control type inverter was used to reduce the torque ripple ant to improve the velocity follow-up. This method calculates Instantaneous actual output torque and flux of induction motor by voltage and current, then compares them with a reference values by a speed regulator. The outputs of comparators select a switching mode, for an optimal voltage vector. Also, this study used IGBT (Insulated Gate Bipolar-Transistor), a high speed switching element, to reduce sound noise level, and DSP (Digital Signal Processor) was used to improve the reliability of the control circuit by fully digitalization.

  • PDF

Modeling of Static Var Compensator with Hybrid Cascade 5-level PWM Inverter Using Circuit DQ Transformation (회로 DQ 변환을 이용한 하이브리드 Cascade 5-레벨 PWM 인버터를 포함하는 무효전력보상기의 모델링)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.421-426
    • /
    • 2002
  • Hybrid cascade multilevel PWM inverter has advantages of hybrid structure which enhances the better utilization of power semiconductor switches, that is, both hi호 power-low frequency switch, GTO and low power-high frequency switch, IGBT can be used in the same circuit. In this paper, a static var compensator using hybrid cascade 5-level PWM inverter is presented for high voltage/high power applications. The proposed system is modelled by circuit DQ transformation, and thus an equivalent circuit is obtained which reveals the important characteristics of the system and lead to the related equations. Finally, circuit structure and characteristics is presented and the validity of the characteristics analysis is shown through PSIM simulation.

Suppression of high frequency leakage current in PWM Inverter-Fed Induction Motor Drives using Active Common Mode Voltage Damper (능동형 커먼 모드 전압 감쇄기를 통한 유도 전동기의 고주파 누설전류 억제)

  • 홍순일
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.186-190
    • /
    • 2000
  • This paper propose a "Active common-mode voltage damper circuit" that capable of a suppression of a common-mode voltage produced in the PWM VSI. The four level half-bridge PWM inverter circuit and common-mode transformer are incorporated into the "Active common-mode voltage damper" the design method of which is presented Effect of "Active common-mode voltage damper" in this paper verifies a propriety and effectiveness in 2.2[kW] induction motor drive using IGBT inverter. Experimental results show that "common-mode voltage damper" makes contributions to reducing a high frequency leakage current and common-mode voltage.leakage current and common-mode voltage.

  • PDF

Development of PWM Converter System for Solar Cell Silicon Ingot Glowing 120kW 3kA (태양전지 실리콘 결정 성장용 120kW 3kA PWM 컨버터 시스템 개발)

  • Kim, Min-Huei;Park, Young-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.125-130
    • /
    • 2014
  • This paper is research result for a development of solar cell silicon ingot glowing(SCSIG) PWM converter system for 120[kW] 3[kA]. The system include 3-phase AC-DC rectifier diode converter of input voltage AC 460[V] and 60[Hz], DC-AC single phase full bridge PWM inverter of high frequency, AC-DC single-phase full wave rectifier using center-tapped of transformer for low voltage 50[V] and large current 3,000[A], carbon resistor load 0.2 [$m{\Omega}$]. PWM switching frequency for IGBT inverter control set 15KHz. The suggested researching contents are designed data sheets of power converter system, PSIM simulation, operating characteristics and analysis results of developed SCSIG system.

Study on the Parallel Resonant Inverter of an High Frequency Induction Heating System which the Frequency Tracking and the Power Regulation is possible (주파수 추종과 정전력 제어가 가능한 고주파 유도가열기의 병렬 공진형 인버터에 대한 연구)

  • 김남수;김태언;김승철;임영도
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.63-66
    • /
    • 2002
  • This paper has been studied the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses. The current-fed full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.