• Title/Summary/Keyword: IF strip

Search Result 96, Processing Time 0.042 seconds

Experiment for Reduction Effectiveness of Pollutants with the Improvement of Infiltration Ability in Vegetation Filter Strip (식생여과대내 침투능력 향상에 따른 오염물질 저감효과에 대한 실험)

  • Lee, Young-A;Choi, I-Song;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.183-190
    • /
    • 2007
  • Soil layer in vegetation filter strip is one of the very important factor for reduction of non-point pollutants by physical, chemical and biological reactions of it through infiltration process. This study was carried out to prepare more effective vegetation filter strip through modification of soil layer for river water quality improvement. Therefore, the main aims of this study are to compare and evaluate normal (straighten type) and modified (step type) vegetation filter strip, which make artificially change the soil layer to improve infiltration ability, through bench scale experiments. In the results of this study, vegetation filter strip of step type is much more highly reduction effectiveness of pollutants in surface flow compared with normal vegetation filter strip. In case of below effluent, however, it appeared that the vegetation filter strip modified soil layer showed lower reduction effectiveness of pollutants than the general vegetation filter strip. This result was judged because effluent through the vegetation filter strip of step type passed bigger size of aggregate or sand than the vegetation filter strip of straighten type. If we compare it as a definition of pollutant load to estimate total amount of reduced pollutants by vegetation filter strip, reduced pollutants load by step type showed higher than those by straighten type because below effluent amount relied on total effluent amount was higher at step type (4%) than at straighten type (2%). In conclusion, the vegetation filter strip of step type to improve infiltration effect is much more reduction effectiveness of pollutants than vegetation filter strip of straighten type.

Linear Modeling and Decoupling Control of Tandem Cold Rolling Mill (연속 냉간압연 시스템의 선형모델 유도와 비간섭 제어기 설계)

  • 박규은;이관호;이준화
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.39-39
    • /
    • 2000
  • In this paper, a decoupler of tandem cold rolling mill is designed. Before designing the decoupler, this paper improved conventional linear model by considering friction and yield stress of rolling strip. In a stand, the decoupler let an output be controlled by an input. And even if states of other stands should be changed, current stand takes no interference from those changes. In addition, with the same method, a feedforward controller is designed for an input strip thickness error. Finally, performance of controllers above is shown with nonlinear simulation.

  • PDF

Analysis of Sediment Reduction with VFS and Diversion Channel with Enhancements in SWAT Landuse-Subbasin Overland Flow and VFS Modules

  • Park, Youn-Shik;Kim, Jong-Gun;Kim, Nam-Won;Engel, Bernie;Lim, Kyoung-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.752-757
    • /
    • 2009
  • In the last decade, many methods such as greet chamber, reservoir, or debris barrier, have been utilized to manage and prevent muddy water problem. The Vegetative Filter Strip (VFS) has been thought to be one of the most effective methods to trap sediment effectively. The VFS are usually installed at the edge of agricultural areas adjacent to stream or drainage ditches, and it has been shown that the VFS effectively removes pollutants transported with upland runoff. But, if the VFS is installed without any scientific analysis of rainfall-runoff characteristics, soil erosion, and sediment analysis, it may not reduce the sediment as much as expected. Although Soil and Water Assessment Tool (SWAT) model has been used worldwide for many hydrologic and Non-Point Source Pollution (NPSP) analysis at a watershed scale. but it has many limitations in simulating the VFS. Because it considers only 'filter strip width' when the model estimates sediment trapping efficiency, and does not consider the routing of sediment with overland flow option which is expected to maximize the sediment trapping efficiency from upper agricultural subbasin to lower spatially-explicit filter strip. Therefore, the SWAT overland flow option between landuse-subbasins with sediment routing capability was enhanced with modifications in SWAT watershed configuration and SWAT engine. The enhanced SWAT can simulate the sediment trapping efficiency of the VFS in the similar way as the desktop VFSMOD-w system does. Also it now can simulate the effects of overland flow from upper subbasin to reflect the increased runoff volume at the receiving subbasin, which is what is occurring at the field if no diversion channel is installed. In this study, the enhanced SWAT model was applied to small watershed located at Jaun-ri in South Korea to simulate diversion channel and spatially-explicit VFS. It was found that approximately sediment can be reduced by 31%, 65%, 68%, with diversion channel, the VFS, and the VFS with diversion channel, respectively.

  • PDF

A Study on the Development of Reinforced Earth wall by Geotextile (토목섬유를 이용한 보강토옹벽의 개발)

  • 도덕현;유능환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.2
    • /
    • pp.63-73
    • /
    • 1986
  • The model was developed by applying the principles of Bacot and Vidal to measure the behavior of deformation of the reinforced earth wall, and various tasts were performed by using the plastic fabric filter and the galvanized steel plate as a strip. The results obtained are as follows; 1. When the reinforced earth wall is deformed by the load, the strip is completely reinforced by the backfill materials and changed to the rigid block state, under the state of failure which permits sliding only, the next theoretical equation is formed. (H/L) . tan$\theta$ [cosO-sinOtanO] =2sinO[tan($\theta$ +0) +tanO] 2.The degree of the mutual reinforcement of the backfill material and the strip depend on the physical characteristics of the each material especially the angle of shearing resistance of the backfill material is desirable over 20$^{\circ}$ and, if it is over 400, its function could be a maximum. 3.The distribution of the maximum tensile strain of the reinforcement is changing with the height of reinforced earth wall, and when the height from bottom of the reinforced earth wall is 1.85 to 3. 35m, the maximum tensile strain appears at 2m from the skin element. The maximum tensile strain is increased by the depth of the reinforced earth wall from surface, and increased with the lapse of time after construction. 4.The failure surface of the reinforced earth wall by the concrete skin was about 60$^{\circ}$and the failure behavior of the reinforced earth wall in which the fabric filter was buried was slow, and so the pore pressure could be decreased. 5.It is possible to construct the fabric retained earth wall by the plastic fabric filter only. And the reinforcing effect between the steel plate and the plastic fabric filter is not largely different. however, in the aspect of the economic durability, the plastic fabric filter is more advantageous. 6.The reinforcing action mainly depends on the width and the length of the reinforcing materials, if possible, the full width is advantageous to enlarge the contact area with backfill. but considering the economic aspect, it is neccessary to develop the method controlling the space of the strip.

  • PDF

Analysis of Dynamic Interaction between Rigid Surface Foundations by 3-D Homogeneous Strip Hyperelement (3차원 Homogeneous Strip Hyperelement를 이용한 표면 강체 기초간 상호 작용 해석)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.109-116
    • /
    • 1997
  • The contiguous or adjacent foundations are always coupled through the soil. Hence their behavior is quite different due to the interaction effects between or among the foundations. The interaction effects can be very pronounced if the distance between them is very close. An 3-D homogeneous strip hyperelement is developed to analyze the dynamic interaction between rectangular or irregular shape found ations. The effects of interaction on the dynamic behaviors of the adjacent rigid rectangular foundations. The effects of interaction on the dynamic behaviors of the adjacent rigid rectangular foundations. The effects of interaction on the dynamic behaviors of the adjacent rigid rectangular foundations resting on the surface of a stratum are stratum are studied using the newly developed method.

  • PDF

A Study on Development of Setup Model for Thickness Control in Tandem Cold Rolling Mill (연속냉간압연의 두께제어 모델 개발에 관한 연구)

  • 손준식;김일수;권욱현;최승갑;박철재;이덕만
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.5
    • /
    • pp.96-103
    • /
    • 2001
  • The quality requirements for thickness accuracy in cold rolling continue to become more stringent, particularly in response to exacting design specification from automotive customers. One of the major impacts from the tighter tolerance level is more unusable product on the head end and tail end of tandem mill coils when the mill is in transition to or from steady state rolling condition. A strip thickness control system for a tandem cold steel rolling mills is composed with blocked non-interacting controller and controllers for strip thickness and tension control of each rolling stands. An intelligent mathematical model included an elastic deformation of strip has been developed and applied to the field in order to predict the rolling force. The simulated results showed that the effect of elastic recovery should be included the model, even if the effect of elastic compression was not important.

  • PDF

Effects of locally-delivered minocycline hcl on controlled periodontal disease (Minocycline 국소 약물 방출 제제의 치주질환 치료 효과)

  • Chung, Mi-Hyun;Kwon, Young-Hyuk;Herr, Yeek;Lee, Man-Sup;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.1
    • /
    • pp.37-56
    • /
    • 1998
  • The purpose of this study was to evaluate the clinical and microbiological outcomes following the use of 30% minocycline-loaded polycaprolacton film and 2% minocycline-loaded gel that was applied locally into pockets combined with scaling and root planing. 25 human subjects who were non-pregnant, non-lactating, aged 20-50 and diagnosed as moderate to advanced adult periodontitis were enrolled. Subjects were excluded if they had a history of severe acute or chronic systemic disease, if they required antibiotic prophylaxis for dental treatment for any reason, or if they reported a history suggestive of hypersensitivity reactions to minocycline or tetracycline. 4quadrants that had several teeth with a 5-8mm probing pocket depth and radiographic evidence of alveolar bone loss for each patient were selected and divided into test sites and control sites according to the split-mouth design. Scaling and root planing was done for each site at baseline(0week). Test sites received the minocycline gel and strip and control sites had saline irrigation. The patients received both treatments simyltaneously. Subgingival irrigation of sterile saline was applied to the control sites for approximately 30 seconds. Minocycline strip and gel was applied into the periodontal pocket at 1, 2, 3, 4 weeks each after scaling and root planing in the test sites. The clinical and microbiological measurements were made at baseline and at the follow-up visits 6, 10, 14, 20 weeks. The results of this study were as follows; 1. The sulcular bleeding index, probing pocket depth and Periocheck test was significantly reduced and the relative proportions of spirochetes and motile rods were significantly reduced and the proportion of cocci was correspondingly increased, in locally delivered minocycline strip group compared to saline irrigation group. 2. In locally delivered minocycline gel group, The effect was the same with minocycline strip group as compared with saline irrigation therapy. 3. There was no significant differences between minocycline strip group and minocycline gelgroup. In conclusion, minocycline HCl local drug delivery combined with scaling and root planing may provide added improvement of clinical and microbiological responses by inhibiting bacterial recolonization of treated sites. It is suggested that the local administration of minocycline-HCl in the periodontal pocket is effective when combined with subgingival mechanical debridement.

  • PDF

Challenges in the Production of Thin Coatings at High Line Speed

  • Michel, Dubois;Luc, Warichet;Jose, Callegari
    • Corrosion Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Cost reduction of products is and will always be a key objective of industrials. However, it is well identified that the wiping process reaches its limits at high line speed in general and especially thin coatings. If wiping models predict that it is possible to reach 32-37 g/$m^2$ of pure Zinc at 180 m/min provided the nozzle to strip distance can be reduced to 6mm, the possibility to reach that process window industrially with sufficient robustness is debated. 3 key problems are reviewed and analyzed: Zinc splashing and liquid drop emissions of various forms, the production of skimming and the noise generated by the nozzles. The available data and models are firstly used to predict phenomena. Secondly, videos and pictures from the lines showing what really happens on the edges especially in case of a strip width change are analyzed. Whereas the predicted level of skimming to remove from the pot is expected very high, it turns out that the target may be very close to the full splashing phenomena and that the most critical industrial situation is related to strip specification changes. It is then expected that the industrial feasibility of the 32-37 g/$m^2$ at 180 m/min will depend strongly on the amount of incoming strip with the same width that can be processed continuously.

THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION (수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구)

  • Park, Sung-Ho;Noh, Byung-Duk;Kim, Mo-Ran;Ahn, Hyun-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.