• Title/Summary/Keyword: IF signal generator

Search Result 53, Processing Time 0.035 seconds

A Roll Rate Estimation Method using GPS Signals in a Spinning Vehicle

  • Cho, Jong-Chul;Kim, Jeong-Won;Hwang, Dong-Hwan;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.303-306
    • /
    • 2006
  • A roll rate estimation method is proposed using the GPS measurement for spinning vehicles such as guided munitions and smart bombs. Before designing the roll rate estimator, the carrier phase and the carrier frequency deviation caused by spinning have been observed. Based on the observation, the spinning frequency is estimated using I and Q value from the correlator. The proposed method is evaluated through computer simulations using a software defined receiver and a GPS IF signal generator.

  • PDF

Quantitative EC Signal Analysis on the Axial Notch Cracks of the SG Tubes (SG Tube 축방향 노치 균열의 정량적 EC 신호평가)

  • Min, Kyong-Mahn;Park, Jung-Am;Shin, Ki-Seok;Kim, In-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.374-382
    • /
    • 2009
  • Steam generator(SG) tube, as a barrier isolating primary to the secondary coolant system of nuclear power plants(NPP), must maintain the structural integrity far the public safety and its efficient power generation capacity. And SG tubes bearing defects must be timely detected and taken repair measures if needed. For the accomplishment of these objectives, SG tubes have been periodically examined by eddy current testing(ECT) on the basis of administrative notices and intensified SG management program(SGMP). Stress corrosion cracking(SCC) on the SG tubes is not easily detected and even missed since it has lower signal amplitude and other disturbing factors against its detection. However once SCC is developed, that can cause detrimental affects to the SG tubes due to its rapid propagation rate. Accordingly SCC is categorized as prime damage mechanism challenging the soundness of the SG tubes. In this study, reproduced EDM notch specimens are examined for the detectability and quantitative characterization of the axial ODSCC by +PT MRPC probe, containing pancake, +PT and shielded pancake coils apart in a single plane around the circumference. The results of this study are assumed to be applicable fur providing key information of engineering evaluation of SCC and improvement of confidence level of ECT on SG tubes.

Design of Single Power CMOS Beta Ray Sensor Reducing Capacitive Coupling Noise (커패시터 커플링 노이즈를 줄인 단일 전원 CMOS 베타선 센서 회로 설계)

  • Jin, HongZhou;Cha, JinSol;Hwang, ChangYoon;Lee, DongHyeon;Salman, R.M.;Park, Kyunghwan;Kim, Jongbum;Ha, PanBong;Kim, YoungHee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.4
    • /
    • pp.338-347
    • /
    • 2021
  • In this paper, the beta-ray sensor circuit used in the true random number generator was designed using DB HiTek's 0.18㎛ CMOS process. The CSA circuit proposed a circuit having a function of selecting a PMOS feedback resistor and an NMOS feedback resistor, and a function of selecting a feedback capacitor of 50fF and 100fF. And for the pulse shaper circuit, a CR-RC2 pulse shaper circuit using a non-inverting amplifier was used. Since the OPAMP circuit used in this paper uses single power instead of dual power, we proposed a circuit in which the resistor of the CR circuit and one node of the capacitor of the RC circuit are connected to VCOM instead of GND. And since the output signal of the pulse shaper does not increase monotonically, even if the output signal of the comparator circuit generates multiple consecutive pulses, the monostable multivibrator circuit is used to prevent signal distortion. In addition, the CSA input terminal, VIN, and the beta-ray sensor output terminal are placed on the top and bottom of the silicon chip to reduce capacitive coupling noise between PCB traces.

A Study on the Operation Method of Emergency Power System with Reserved Firefighting Power (RFP) (소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.29-34
    • /
    • 2012
  • The purpose of this study is to propose an effective operating method of a power generator used by the Emergency Power System in case of a simultaneous fire and of the limitations of the interlock system the power supply from the emergency power generator. On the Emergency Power System with Reserved Fire-fighting Power (RFP), in case of an overload, the collective control Emergency Power System signals the main circuit breaker to shut off the supply to the emergency load, leaving the supply to the firefighting load uninterrupted to the end. The sequential control Emergency Power System signals the firefighting power supply to shut off the fire stage of the emergency load and continues to monitor the power supply. If an overload happens again from increased firefighting load, the sequential control Emergency Power System sends a secondary signal to shut down the second stage of the emergency load.

Analysis of Global Oscillation via Sync Search in Power Systems (전력계통에서 동조탐색과 광역진동해석)

  • Shim, Kwan-Shik;Nam, Hae-Kon;Kim, Yong-Gu;Moon, Young-Hoan;Kim, Sang-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1255-1262
    • /
    • 2009
  • The present study explained the phenomenon that low frequency oscillation is synchronized with discrete data obtained from a wide area system, and a sync search method. When a disturbance occurs in an power system, various controllers operate in order to maintain synchronization. If the system's damping is poor, low frequency oscillations continue for a long time and the oscillations are synchronized with one another at specific frequency. The present study estimated dominant modes, magnitude and phase of signals by applying parameter estimation methods to discrete signals obtained from an power system, and performed sync search among wide area signals by comparing the estimated data. Sync search was performed by selecting those with the same frequency and damping constant from dominant oscillation modes included in a large number of signals, and comparing their magnitude and phase. In addition, we defined sync indexes in order to indicate the degree of sync between areas in a wide area system. Furthermore, we proposed a wide area sync search method by normalizing mode magnitude in discrete data obtained from critical generator of the wide area. By applying the sync search method and sync indexes proposed in this study to two area systems, we demonstrated that sync scanning can be performed for discrete signals obtained from power systems.

Dedicated Cutback Control of a Wind Power Plant Based on the Ratio of Command Power to Available Power

  • Thapa, Khagendra;Yoon, Gihwan;Lee, Sang Ho;Suh, Yongsug;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.835-842
    • /
    • 2014
  • Cutback control in a grid code is one of the functions of a wind power plant (WPP) that is required to support the system protection and frequency stability. When a cutback control command signal is delivered to the WPP from the system operator, the output of a WPP should be decreased to 20% of the rated power within 5 s. In this paper, we propose a dedicated cutback control algorithm of a WPP based on the ratio of the command power to the available power. If a cutback control signal is delivered, the algorithm determines the pitch angle for the cutback control and starts the pitch angle control. The proposed algorithm keeps the rotor speed at the speed before the start of the cutback control to quickly recover the previous output prior to the cutback control. The performance of the algorithm was validated for a 100 MW aggregated WPP based on a permanent magnet synchronous generator under various wind conditions using an EMTP-RV simulator. The results clearly shows that the proposed algorithm not only successfully reduces the output to the command power within 5 s by minimizing the fluctuation of the pitch angle, but also rapidly recovers to the output level before the cutback control.

A Study on Pattern Recognition for Searched Fish.seashell on Seabed Using Ultra Sonic (초음파를 이용한 어.패류 탐지와 패턴인식에 관한 연구)

  • 김재갑;김원중
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.410-418
    • /
    • 2000
  • In general, the experienced diver go into the water to find out Pan Shell which is spontaneously generated and brought up at the depth of 25-30 meters in the slime along the bank of an inlet of western and southern sea. However, this searching system has caused some problems in terms of economical efficiency and riskiness of diver. To overcome such problems and enhance the competence capability of fishermen, a new Pan Shell searching system is required. If an onboard searching system as a substitute of the way of diving into the deep water to identify the existence of Pan Shell is developed, it would be greatly beneficial to fishermen. The purpose of this research is to develop a new searching system of Pan Shell by making use of 50-200 Khz Ultra Sonic Signal, A/D Converter and computer process program. Based on the fact that Sonic Signal between the soft part of slime and the hard part of sand, pebble and Pan Shell is different, the possibility of this system have been approved in some degree by this time of research. However, to utilize this new system, further research on the establishment of data base and sample data is required. With the theoretical knowledge, the systematic research on the searching capability of Ultra Sonic Signal will be continued to identify the influence against the sea water subject. In this research, signal will be analyzed according to the influence range, power and sensitiveness of Ultra Sonic Generator. In addition, the radius of Ultra Sonic Signal will be included. The experimental field work will be executed at Nockdong, Pulkyo and other places well known as a habitat of Pan Shell.

  • PDF

Stabilization of Dry Immuno-Diagnostic Kit with Immobilized Antibody and Determination of Its Shelf-Life (항체가 건조상태로 고정된 면역진단키트의 안정화와 Shelf-Life 결정)

  • 이창우;조정환;육순학;권오협;박영남;박세환
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.502-510
    • /
    • 1998
  • Stabilization of antibody, which is specific to Salmonella typhimurium antigens, present in dry states on membranes was accomplished, and its shelf-life, i.e., duration for maintaining minimum 90% of the initial activity, under optimal conditions was determined. To prepare two major components of an immuno-strip, the antibody was not only immobilized on nitrocellulose membrane surfaces but also placed within the pores of glass fiber membrane after conjugating it with old colloids as signal generator. Among potential stabilizers of the immuno-components, a disaccharide, trehalose, showed a significant protection effect of immunoglobulin structure from thermal energy. Optimal concentrations of trehalose for the respective component were significantly different (8-fold higher for the antibody-gold conjugate than for the immobilized antibody), which probably resulted from distinct densities and configurations of antibody present on the membranes. An additional requirement for the gold conjugate was freeze-drying of this substance such that the conjugate can be readily resolubilized upon contact with aqueous medium. By using the components prepared under optimal conditions, immuno-strips were constructed and exposed to thermal energy. Signals with less than 10% decrease in the intensity were maintained for approximately 21 days at 60$^{\circ}C$. Compared to previous reports, this result represented a 2-year shelf-life at room temperature. it was, however, two times longer if determined from thermal acceleration tests based on the theory of inactivation rate of protein. Such discrepancy between the two estimates could be mainly attributed to errors in accurately controlling temperatures and also to changes in the physical properties of membranes due to a high thermal energy.

  • PDF

T-DMB Automatic Emergency Alerting Service by Estimating the Location of Receiver (단말기 위치 자동 인식을 이용한 T-DMB 자동재난경보서비스)

  • Kwon, Seong-Geun;Lee, Suk-Hwan;Kim, Kang-Wook;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.5
    • /
    • pp.615-623
    • /
    • 2012
  • This paper presents T-DMB AEAS (automatic emergency alerting service) receiver model considering emergency region. The proposed receiver model determines the geographical location of the terminal by analysing the received T-DMB signal and displays the AEAS messages only if the location of terminal is similar to the emergency site. First, to determine the geographical location of the terminal, we extract the TII value from the null symbol of the SC and, based on it, calculate the location of transmitter by analysing FIG 0/22 delivering the TII-related data. The proposed algorithm sets the location of transmitter as that of receiver and displays the emergency message only in the case of the similar region. The experiment was conducted in the test environment of low power T-DMB generator based on the T-DMB AEAS messages.

Relationship Between the Initiation and Propagation of SCC and the Electrochemical Noise of Alloy 600 for the Steam Generator Tubing of Nuclear Power Plants

  • Kim, Y.S.;Nam, H.S.;Kwon, Y.H.;Kim, S.W.;Kim, H.P.;Chang, H.Y.
    • Corrosion Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.57-66
    • /
    • 2010
  • Since nuclear power plants are being operated under high temperature and high pressure, on-line monitoring technique to detect corrosion could be more effective than off-line method in shut-off period. In this operating condition, electrochemical noise method may be suitable to monitor the corrosion. This paper aims the analysis on the relation between the cracking and electrochemical noise signal of Alloy 600 under U-bending. When electrochemical noise monitoring technique was used during SCC test, it was judge to be obvious that if cracks generate, its generation can be detected by electrochemical current noise. Cracking-related noise was defined as the noise showing 5~10 times greater than the average value of background noise bands. On the base of crack noise, crack initiation time was determined. From SCC test and electrochemical noise monitoring in $25^{\circ}C$, 0.1 M $Na_2S_4O_6$ solution (Reverse U-Bended Alloy 600 SE+), average crack initiation time was obtained as 9,046 seconds and from its initiation time, it could be defined that net crack propagation rate is the crack length divided by ${\Delta}T$(= total test period - crack initiation time). Therefore, average net crack propagation rate was obtained to be $1.18{\times}10^{-9}\;m/s$.