• Title/Summary/Keyword: IED

Search Result 301, Processing Time 0.035 seconds

154kV Main TR. Bay IED Based On IEC 61850 (IEC 61850 기반의 154kV M.Tr Bay IED 적용 사례)

  • Roh, Jae-Keun;Oh, Jae-Hoon;Yang, Hang-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2028-2034
    • /
    • 2011
  • Substation Automation System (SAS) based on IEC 61850 is becoming more and more reality in applying power systems. As well, the development of various engineering tools and the convergence with diagnostic systems are underway. To reflect recent advancements in SAS technology, the Korea Electric Power Corporation initiated a 154kV SAS pilot project and a smart power grid business in 2010. In this paper, the authors will summarize the overview and the lessons learned in applying the IEC 61850-based 154kV Main transformer bay IED solutions to these two project.

Design of Multi-protocol IED for Networked Control System of Multi-Induction Motor in Industrial Fields

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.60-71
    • /
    • 2012
  • This paper proposes a new design and implementation of multi-protocol IED for networked control system of multi-induction motor in industrial fields. The experimental multi-induction motor based multi-protocol IED of Modbus/LonTalks/TCP/IP module is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting Modbus protocol to LonTalks protocol, integrating preconfigured software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, especially, the seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide available technical data for remote distributed motor control system of industrial field or building microgrid with LonWorks BAS.

Construction of IED Conformance Testing System (IED 적합성 인증시험 장치 구축)

  • Lee, N.H.;Kim, J.H.;Jang, B.T.;An, Y.H.;Hwang, K.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.489-490
    • /
    • 2007
  • In order to construct a digital substation based on IEC61850, All of the utility company should used IEDs to be verified and also vendors should get a certification from the international conformance testing organizationsuch as KEMA. So KEPRI in charge of POWER IT project related to SAS was required to IED conformance testing system, which can perform the test previously. The system, KEPCO developed, consists of HMI, IED (Intelligent Electronic Device), network equipment, V/I generator etc

  • PDF

Hardware Design of IED using DSP for Power Transformer Protection (DSP를 이용한 전력용 변압기용 IED의 하드웨어 설계)

  • Park C. W.;Jung Y. M.;Ha K. J.;Koo C. S.;Shin M. C.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.363-365
    • /
    • 2004
  • This paper proposes a hardware implementation of intelligent electronic device for power transformer protection. And proposes an advanced main protection algorithm by voltage-current trend and flux-differential current slope characteristics. The secondary protection functions include UR, OCGR, OVR, and W etc. The main board of IED is based on the DSP chip TMS32C32 processor The IED was tested with relaying signals obtained for EMTP simulation package.

  • PDF

Estimation of Potential Population by IED(Improvised Explosive Device) in Intensive Apartment Area (아파트 밀집지역 급조폭발물 테러 발생 시 잠재피해인구 추정)

  • Lee, Kangsan;Choi, Jinmu
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.76-86
    • /
    • 2015
  • In this study, we presented a method for estimating the potential population damage of the Seoul Nowon-gu area in the event of a terrorist using a vehicle improvised explosive devices (IED). Using the object-based building extraction method with orthophoto image, the area of the apartment has been determined, and the apartment's height and level were estimated based on the elevation data. Using the population estimation method based on total floor area of building, each apartment resident population was estimated, and then potential population damage at the time of terrorist attacks was estimated around the subway station through a scenario analysis. Terrorism damage using IED depends on the type of vehicle greatly because of the amount loadable explosives. Therefore, potential population damage was calculated based on the type of vehicle. In the results, the maximum potential damage population during terrorist attacks has been estimated to occur around Madeul station, Nowon-gu. The method used in this study can be used various population estimation research and disaster damage estimation.

  • PDF

The Design of Operation and Control Solution with Intelligent Inference Capability for IED based Digital Switchgear Panel (IED를 기반으로 하는 디지털 수배전반의 지적추론기반 운전제어 솔루션 설계)

  • Ko, Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.9
    • /
    • pp.351-358
    • /
    • 2006
  • In this paper, DSPOCS(Digital Switchgear-Panel Operation and Control Solution) is designed, which is the intelligent inference based operation and control solution to obtain the safety and reliability of electric power supply in substation based on IED. DSPOCS is designed as a scheduled monitoring and control task and a real-time alarm inference task, and is interlinked with BRES(Bus Reconfiguration Expert System) in the required case. The intelligent alarm inference task consists of the alarm knowledge generation part and the real-time pattern matching part. The alarm knowledge generation part generates automatically alarm knowledge from DB saves it in alarm knowledge base. On the other hand, the pattern matching part inferences the real-time event by comparing the real-time event information furnished from IEDs of substation with the patterns of the saved alarm knowledge base.; Especially, alarm knowledge base includes the knowledge patterns related with fault alarm, the overload alarm and the diagnosis alarm. In order to design the database independently in substation structure, busbar is represented as a connectivity node which makes the more generalized graph theory possible. Finally, DSPOCS is implemented in MS Visual $C^{++}$, MFC, the effectiveness and accuracy of the design is verified by simulation study to the typical distribution substation.

The Implementation of IED for Diagnosis of Electric Devices (전력 설비 진단을 위한 IED 의 구현)

  • Oh, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1110-1111
    • /
    • 2007
  • These days, the concerns about maintenance and repair of electric facilities for stable and reliable electric power supply are increasing day by day. Because, we can have enormous damages economically and socially from a problem of the facilities, no matter how it is a small one. Especially, electric facilities in our country had been built abruptly from 40 years ago, so it can be thought that here are great amount of old facilities that must be repaired or replaced with new one, and the number would be increased time by time. On this situation, many researchers are studying the efficient and reliable method of maintenance for electric facilities and the results are applied on the facilities gradually by growing interests of operators and managers of the facilities. In this paper, the IED(Intelligent Electronic Devices) for Diagnosis system of electric machines are described. It takes analog data from a sensing device and operates digital processor to get a optimum digital data for diagnosis system. Now, this device is applied on several high voltage substations to diagnose and maintain GIS. Brief schematic of total diagnosis system and the construction of the IED are included in this paper.

  • PDF

Study on the Metamaterial Design Methodology to Reduce the Size of the Bandpass Filter for the Smart Grid IED (스마트그리드 IED용 대역통과여파기 소형화를 위한 메타재질구조 설계법 연구)

  • Kahng, Sung-Tek;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2299-2304
    • /
    • 2011
  • In this paper, we propose the methodology to make the bandpass filters for the Smart Grid IED(Intelligent Electronic Device) smaller than the conventional bandpass filters. The size-reduction of the filters and the filter performances are indebted to devising small CRLH(composite right- and left-handed) resonators and coupling them as the metamaterial structures. The design methodology is validated by the equivalent circuit to be compared with the reliable full-wave EM simulation, and the proposed metamaterial filter outperforms the standard parallel-edge coupled filter with respect to the miniaturization and frequency response.

A Study on the Application of the Test Automation System on a D/L IED based on IEC 61850 (IEC 61850 배전선로 IED의 시험자동화시스템 적용에 관한 연구)

  • Jang, B.T.;Lee, N.H.;Lee, M.S.;Youn, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.266-267
    • /
    • 2011
  • IEC 61850 기반의 변전자동화를 운영하는데 있어 보호기능과 통신을 별개로 여길 수가 없으며 기존에 장치 개별로 동작하던 것이 이더넷 통신이란 틀 안에서 시스템으로 유기적으로 연결되어 동작하기 때문에 IEC 61850 통신과 기능을 시스템 기반에서 수행할 수 있는 새로운 방안이 요구되어진다. 본 논문은 변전자동화시스템의 종합적인 성능검증을 목적으로 개발된 시험자동화시스템의 실제 적용가능성을 검증하고, 변전자동화 시스템의 22.9kV 배전선로 보호 및 제어의 기능을 수행하는 IED를 대상으로 시험자동화시스템에 적용한 연구 내용을 다루고자한다.

  • PDF