• Title/Summary/Keyword: IED

Search Result 301, Processing Time 0.038 seconds

A Implementation of the Intelligent Electronic Device for Power System Automation (전력 시스템 자동화를 위한 디지털 전력장치의 구현)

  • Oh Jae-Hoon;Hong Jung-Gi
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.435-438
    • /
    • 2004
  • Lately, the Intelligent Electronic Device(ED) and the Power System Automation make subjects of discussions and studies. The IED uses microprocessors to practice a lot of functions. In the analog time, an equipment practices only one or two functions. But according to the development of microprocessor and digital technology, it can be implemented by using those kinds of state of the art technology and its function is become more and more powerful. Also, the proliferation of IED makes possible to construct power system automation. An automation of power system make more convenient, safe, and accurate power system. In this paper, a digital protective relay which is a kind of IED and the power automation system are briefly discussed with development and application cases.

  • PDF

A Study of the Reliability Improvement Scheme on IEC61850 Environment Using Multi-Agent (IEC61850 환경에서의 다중 에이전트를 이용한 신뢰도 향상기법에 관한 연구)

  • Park, Dong-Ho;Rim, Seong-Jeong;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.232-233
    • /
    • 2006
  • 변전소에서 IED의 신뢰성은 전력시스템의 보호 제어에 있어서 매우 중요한 문제이다. 실제로 다른 제조업체로부터의 IED의 사용은 신뢰도를 유지하는데 많은 어려움을 가지게 된다. 본 논문에서는 IEC61850 기반의 변전소에서 다중 에이전트를 이용한 신뢰도 향상기법을 제안하였다. 백업 IED와 네트워크에서의 데이터 전송을 활용하여 다중 에이전트에서 각각의 에이전트들은 결함검출, 시험패턴 데이터 생성, 리소스 표시 및 확인 등의 기능을 수행한다. 제안한 방법은 구현을 통하여 그 유용성을 입증한다.

  • PDF

Study on Substation IED Technical Specification based on IEC61850 (IEC61850을 적용한 변전소 IED반 기술규격에 관한 연구)

  • Kim, Hae-Nu-Ri;Kim, Myong-Hoe;Kim, Il-Dong;Jang, Byung-Tae;Jung, Gil-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.294-295
    • /
    • 2006
  • 최근 전력 계통 분야에서 통합화, 자동화가 활발히 이루어지고 있다. 그래서 기존의 전기장비들이 통신 기능을 갖는 마이크로 프로세스 기반의 ED(Intelligent Electronic Device)로 대체하게 되었고 이로 인해 IEC61850기반의 IED구현에 대한 관심이 급증하고 있고 활발히 진행되고 있다. 단일 표준화가 이루어지기 전 다양한 프로토콜의 사용에 따른 호환성 결여 문제를 IEC61850을 통해 해결할 수 있게 되었다. 이로 인하여 기존 기술규격 또한 달라져야 한다. 본 논문은 1차 설비와의 인터페이스 및 통신장치들이 IEC61850적용을 위해 갖추어야 하는 IED반의 기술적인 요구사항들을 검토하고 언급하였다.

  • PDF

A Study on the Design of Operation and Control Solution for IED based Digital Switchgear Panel (IED기반 디지털 수배전반의 운전제어 솔루션 설계)

  • Ko, Yun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.141-142
    • /
    • 2006
  • In this paper, DSPOCS(Digital Switchgear Panel Operation and Control Solution) is designed, which is the intelligent inference operation and control solution of substation based on IED. DSPOCS is designed as a scheduled monitoring and control task and a real-time alarm inference task, and is interlinked with BRES in the required case. The intelligent alarm inference task consists of the alarm knowledge generation part and the real-time pattern matching part The alarm knowledge generation part generates automatically alarm knowledge from DB and saves it in alarm KB. On the other hand, the pattern matching part inferences the real-time event by comparing the real-time event information furnished from IEDs of substation with the patterns of the saved alarm knowledge base.

  • PDF

A Study on Message Transmission Technical for IEC 61850 based Intelligent Electronic Devices (IEC 61850 기반 IED 구현을 위한 메시지 전송 기술에 관한 연구)

  • Kim, Gwan-Su;Lee, Hong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.18-20
    • /
    • 2005
  • 최근 송배전 시스템 분야에서 종래의 인간의 개입을 최소화하여 이루어질 수 있도록 통합화, 자동화 및 원격 감시화가 추진되고 있으며 이는 기존의 전기 장비들을 통신 기능을 갖는 마이크로 프로세스 기반의 IED(Intelligent Electronic Device)로 대체함으로써 가능해 졌다. 단일 표준화 작업이 이루어지기 전 다양한 프로토콜의 사용에 따른 장비 간 호환성 결여로 통신 프로토콜 표준화 필요성이 강하게 제기되었고, 1990년대 표준화 작업을 시작하여 최근 변전소 자동화용 단일 세계 표준인 IEC 61850이 UCA2.0과 유럽의 경험을 기반으로 IEC주관아래 개발되었다. 이러한 세계기술 동향을 반영해 IEC 61850 기반의 종합변전소 자동화 시스템의 구축이 필요하고, 이에 따라 본 논문에서는 IEC 61850 통신 프로토콜을 살펴보고 기본적인 IED 통신 실험 장치를 구성하고 메시지 전송 실험을 수행하였다.

  • PDF

Development of the iron-cored electronic voltage transformer (철심 코어형 전자식 전압 변성기 개발)

  • Kang, Yong-Cheol;Park, Jong-Min;Jang, Sung-Il;Kim, Yeon-Hee;Choi, Jung-Hwan;Kim, Yong-Kyun;Song, In-Jun;An, Yong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.138-139
    • /
    • 2008
  • An iron-cored voltage transformer(VT) is usually used to obtain the standard low voltage signal for protection and measurement. Generally, the iron-cored transformers have errors due to the hysteresis characteristics of the iron-core. An error compensating algorithm for iron-cored instrument transformer can improve the accuracy of conventional voltage transformers. This paper describes the iron-cored electronic voltage transformer having the error compensating algorithm. The innovative product composes an iron-cored VT and an intelligent electronic device(IED) having the error compensating algorithm. The test results of the iron-cored electronic voltage transformers in Korea Electro-technology Research Institute(KERI) are presented.

  • PDF

Development of the Iron-cored Electronic Zero-Phase Current Transformer (철심 코어형 전자식 영상 변류기 개발)

  • Kang, Yong-Cheol;Jang, Sung-Il;Kim, Yeon-Hee;Park, Jong-Min;Kim, Yong-Kyun;Choi, Jung-Hwan;Lee, Byung-Sung;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.140-141
    • /
    • 2008
  • Generally, an iron-cored instrument transformer has differences between the primary current and the secondary current transformer due to the hysteresis characteristics of the core. The errors of the instrument transformer can be removed by using a compensating algorithm. This paper describes the iron-cored electronic zero-phase current transformer(EZCT) having a compensating algorithm that removes the effects of the hysteresis characteristics of the iron-core. This product composes an iron-cored ZCT and an intelligent electronic device(IED) ported the compensating algorithm. The test results shows that the innovative new product can improve the performance of the conventional ZCT.

  • PDF

A Study on the Protection IED for Shunt Reactor Using IEC 61850 Protocol (IEC61850 프로토콜을 이용한 분로리액터 보호용 IED에 관한 연구)

  • An, Yong-Ho;Song, In-Jun;Han, Jung-Youl;Gu, Choon-Seo;Jo, Yong-Ik;Gu, Sung-Wan;Oh, Seong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.131-133
    • /
    • 2008
  • 최근 전력계통 분야에서는 IEC에서 제정한 변전소 자동화용 국제 규격 프로토콜인 IEC 61850을 적용한 시스템의 도입 및 적용이 활발하게 이루어지고 있다. 이러한 추세에 맞추어 변전소 내 많은 전력기기들의 IEC 61850 프로토콜을 탑재가 요구되고 있으며, 본 연구에서는 변전소 내 조상설비 중 IEC 61850 프로토콜을 적용한 분로리액터 보호용 IED의 설계, 제작, 시험을 통하여 변전자동화 가능성을 확인하였다.

  • PDF

Study on the GOOSE Conformance Testing of IEC 61850 based IED (IEC 61850 대상 IED GOOSE 적합성 통신 시험에 관한 연구)

  • Jang, B.T.;Lee, N.H.;Kim, H.J.;Kim, B.H.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.239-240
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project, "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology". This paper describes GOOSE testing, one of the IEC 61850 conformance testing items, which consists of 14 publish and subscribe test cases.

  • PDF

Study on the Report Conformance Test of IEC 61850 based IED (IEC 61850기반 IED 대상 리포트 적합성 시험에 관한 연구)

  • Lee, N.H.;Jang, B.T.;Kim, J.H.;Song, I.J.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.241-242
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project, "The verification of Performance of the Substation Automation System and Its Field Test". This paper presents reporting services of IEC 61850-8-1 and related UCA Test procedures, reporting test items are widely divided into unbuffered report and buffered report and this paper is dealing with unbuffered report.

  • PDF