• Title/Summary/Keyword: IEC Standard

Search Result 849, Processing Time 0.033 seconds

A Development of MiTS Service Modules based on Light-Weight Ethernet (Light-Weight Ethernet 기반 MiTS 서비스 모듈 개발)

  • Hwang, Hun-Gyu;Yoon, Jin-Sik;Seo, Jeong-Min;Lee, Seong-Dae;Lee, Jang-Se;Park, Hyu-Chan;Jang, Kil-Woong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.8
    • /
    • pp.1180-1187
    • /
    • 2010
  • In these days, data processing rate is increasing on shipboard. To solve the problems on the rate, Ethernet based IEC 61162-4 series standard established for integrated information management. But the standard is difficult to implement, so it is changed into Light-weight Ethernet standard. In this paper, we analyze the existing standard and compare it with Light-weight Ethernet standard. As a result, we draw its service requirements. Also we propose the services, and design and implement the service modules.

Analysis for Valve insulation test method of IEC standard (IEC Standard의 밸브 절연 시험 방법 분석)

  • Choi, Yong-Kil;Lee, Wook-Hwa;Chung, Yong-Ho;Na, H.K.;Lee, D.J.;Moon, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.350-351
    • /
    • 2011
  • 본 논문은 HVDC 밸브 절연 시험 방법에 대한 분석 및 고전압 절연 시험에 대한 IEC 규격 분석을 다루었다. 본 논문에서는 고전압 국제 규격 및 시험 방법을 분석함으로써, 저전압 절연 시험과의 차이, 고전압 절연 시험의 설계 및 시험, 국제 규격의 이해를 돕고자 함을 그 목적으로 한다.

  • PDF

A Study on a Safety Life Cycle of IEC 61508 for Functional Safety (기능안전을 위한 IEC 61508의 안전수명주기에 관한 연구)

  • Kim, Sung Kyu;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.81-91
    • /
    • 2014
  • The IEC 61508 standard was established to specify the functional safety of E/E/PE safety-related systems. Safety life cycle to provide the framework and direction for the application of IEC 61508 is included in this standard. In this paper, we describe overviews, objects, scopes, requirements and activities of each phase in safety life cycle. In addition, we introduce safety integrity level(SIL) which is used for verifying the safety integrity requirements of E/E/PE system and perform a case study to estimate hardware SIL by FMEDA. The SIL is evaluated by two criteria. One of them is the architectural constraints which restrict the maximum SIL by combination of SFF and HFT. The other is the probability of failure which is classified into PFD and PFH based on frequency of demand and calculated by safe or dangerous failure rates.

On Reliability Performance of Safety Instrumented Systems with Common Cause Failures in IEC 61508 Standard (공통원인고장을 고려한 안전제어시스템의 신뢰성 평가척도에 관한 고찰 : IEC 61508을 중심으로)

  • Seo, Sun-Keun
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.405-415
    • /
    • 2012
  • The reliability performance measures for low and high or continuous demand modes of operation of safety instrumented systems(SISs) are examined and compared by analyzing the official definitions in IEC 61508 standard. This paper also presents a status of common cause factor(CCF) models used in IEC 61508 and problems relating CCF modelling are discussed and ideas to solve these ones are suggested. An example with mixed M-out-of-N architecture is carried out to illustrate the proposed methods.

Substation Automation System Design Process Based on IEC 61850 SCL (IEC 61850 SCL기반 변전소 자동화 시스템의 구성방법)

  • Zhang, Da-Peng;Rim, Seong-Jeong;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.62-64
    • /
    • 2006
  • With the advent of the international standard IEC 61850 for communication networks and systems in substations, utilities are beginning to implement substation automation systems (SAS) that can give support to interoperability, interchangeability and self-description features. This paper describes with the SAS design accordance with this new standard. After a brief introduction of IEC 61850 SCL, this paper addresses some issues related to the specification of an IEC 61850 based SAS, and describes the Substation Configuration Language (SCL) based on Extensible Markup Language (XML). The SAS design process is explored with examples including the Intelligent Electronic Device (IED) selection, Logical Nodes (LN) allocation and the related services and the SAS communication architecture.

  • PDF

The Configuration Method of trip logic for IEC 61850 based IED using XML (IEC 61850 기반 IED의 XML을 이용한 트립로직 구성)

  • Go, Chol-Jin;Jin, Yong-Woo;Kim, Kyong-Taek;Kim, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.315-316
    • /
    • 2006
  • As IEC 61850 based substation automation technology is emerging globally, there are many efforts to implement and apply this IEC 61850 standard to substation automation area. IEC 61850 based substation supports ethernet network, standard data model and SCL(substation Configuration Language), etc. These features can provide enough environment to make applied technology which can substitute the legacy relay trip logic configuration method(PLC or Local area reconstruction) to XML based configuration method. This paper suggests new IED trip logic configuration method. The XML based trip logic configuration method can be established using SCL technology And IED trip logic reconfiguration from remote center can be possible under ethernet based technology

  • PDF

Characteristics and Implementation of ISO/IEC 27001 : 2013 Information Security Management System (ISO/IEC 27001 : 2013 정보보안경영시스템의 특징과 적용 방안)

  • Song, Kyung-Il;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.108-113
    • /
    • 2014
  • The demand against the risk analysis and information security of system from the companies or the agencies which operate an information system is increasing. ISO/IEC 27001 was established by ISO (International Organization for Standardization) and IEC (International Electrotechnical Commission). Also this standard is international and authoritative standard of ISMS (Information Security Management System). This paper is to review how the ISO 27001 ISMS Requirement has been established and improved, and to communicate the significant changes from ISO27001 : 2005 to ISO 27001 : 2013 focusing on reasons for revisions. Additionally, This paper shows case study for understanding ISO 27001 : 2013 implementation.

Safety Characteristics Analysis of Korean Std. Protocol for Railway Signalling according to IEC 62280 (IEC 62280을 통한 철도신호용 표준 통신프로토콜의 안전특성 분석)

  • Hwnag, Jong-Gyu;Jo, Hyun-Jeong;Yoon, Yong-Ki;Kim, Yong-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.863-869
    • /
    • 2006
  • The existing Europe Standard, EN 50159 with respect of safety of railway signalling communication protocol has been changed into International Standard, IEC 62280. This Standard presents the requirement for safe communication between safety-related devices which connects with transmission system, there are both closed and open transmission system. Regardless of this international Standards, the communication protocol for interface between CTC communication server and external facilities has been standardized several years ago in our country, so this is applied to integrated CTC system in KORAIL. Two Standards are currently standardized as a protocol between CTC and external facilities, these standard protocols are also required high level safety as a communication link which is transmitted vital control information in common with the train control system. For that reason, we have made analysis of requirement for the safe transmission required by international standard. Under this analysis, we have studied safety features of communication protocol applying to our standard. In other words, we have researched that how many the requirement from international standard for safe transmission is reflected in domestic standard protocol, and also whether our standard makes sure of safety enough or not.

  • PDF

Field Test on IEC60364-4-44 for the Application in Korean distribution system (IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

Analysis of RFID Standard Patent Data for RFID Technology Trends (RFID 표준특허 데이터 분석을 통한 RFID 기술 동향)

  • Rho, Seungmin
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.2
    • /
    • pp.185-190
    • /
    • 2014
  • RFID technology as a typical convergence technology combines RFID communication, mobile communication and network infrastructure, and information processing technology. As it enables users to communicate with the surroundings, RFID technology is now recognized to serve as the basis technology for the ubiquitous information society where users can get the needed information anytime and anywhere. Through lots of efforts for the early technology development and standardization activities on RFID technology, Korea has been leading technology standardization as well as technology initiatives. Thus in this paper, we discuss the RFID technology trend by analyzing RFID standard patent data which is declared in international organization for standardization (ISO, IEC, ITU). Especially, we analyzed 906 standard patents data that declared in International organization for standardization (SO, ISO/IEC JTC1, ITU-T) on June 2013.