• 제목/요약/키워드: IEC 61400-4

검색결과 17건 처리시간 0.019초

Development of Wind Turbine Simulation System Based on IEC 61400-25 Standard

  • Lee, Jae-Kyung;Kim, Dong-Wook;Kim, Seok-Tae;Chae, Chang-Hun;Park, Joon-Young
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.349-359
    • /
    • 2019
  • This paper introduces a wind turbine simulation system based on the IEC 61400-25 standard to simulate different kinds of wind turbines. A unified communication protocol was required for monitoring and control of wind turbines, because manufacturers had used their own protocols for their turbines. As a result of such an effort, the international standard IEC 61400-25 was established. To implement the schema of IEC 61400-25, the IEC61850 SCL was modified and applied to the simulation system, which enabled the system to be compatible with heterogeneous wind turbine information models. The developed simulation system can be used for interoperability tests with a new type of wind turbine information model.

풍력발전 설비용 IEC 61400-25 기반 통신 시스템 구축 (Implementation of IEC 61400-25 based communication system for wind power plants)

  • 이정훈;김태오;이홍희
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1356-1362
    • /
    • 2009
  • IEC 61400-25(Communications for monitoring and control of wind power plants) is established as a international standard by IEC TC 88 in 2007 with the growth of the wind power industry. In this paper, MMS service which is defined in lEC 61400-25 part 4 is implemented, and the wind power generator is objectified by using the VMD of MMS service. We also implemented MMS communication system between the wind power generator and the local control center using the proposed VMD. The performance of the developed MMS communication system is verified through the XML based user interface on the web browser.

IEC 61400-2에 의거한 소형 풍력발전용 블레이드 축소모델의 단순 하중 계산 및 구조 시험 (Simplified Load Calculation and Structural Test for Scale Down Model of Small Wind Turbine Blade according to IEC 61400-2)

  • 장윤정;강기원
    • 한국융합학회논문지
    • /
    • 제4권3호
    • /
    • pp.1-5
    • /
    • 2013
  • 본 연구에서는 소형풍력발전용 블레이드의 축소모델을 대상으로 단순 하중 계산 및 구조 시험을 수행하였다. 먼저, 연구 대상인 블레이드의 초기 모델의 0.2 비율만큼 축소하여 설계 및 제작하였다. 그리고 소형 풍력발전 국제 규격인 IEC 61400-2에 의거한 단순 하중 계산식을 이용하여 모멘트를 획득하였다. 또한, 추를 이용한 구조시험을 수행하여 최대 모멘트를 획득하였다. 이를 통하여 계산 및 시험에 따른 최대 모멘트를 비교하였다.

IEC 61400-1 DLC1.1과 DLC1.3에 대한 풍력터빈의 극한하중 특성 (Characteristics of Ultimate Load in a Wind Turbine for IEC 61400-1 DLC1.1 and DLC1.3)

  • 김충옥;남현우;음학진;김귀식
    • 한국태양에너지학회 논문집
    • /
    • 제32권1호
    • /
    • pp.15-24
    • /
    • 2012
  • IEC 61400-1 requires design lifetime of wind turbines at least 20 years, thus wind turbine should be assured for structural safety through load assessment. DLCs have been defined with respect to the load assessment in IEC 61400-1. In addition, if the extreme design values for DLC1.3 are equal or exceed the extreme design value for DLC1.1, DLC1.1 may be omitted. To omit DLC1.1, scale factor (c) will be increased in DLC1.3. However, this particular adjustment is not specified guidelines. Thus, this study was conducted. DLC1.1 was calculated for extrapolation of 50 years-extreme events using several probability distribution functions and fitting methods. And DLC1.3 was calculated for up to seven different values of scale factor (c) with $2{\leq}c{\leq}5$ in steps of 0.5. Finally, in this study, scale factor (c) that was the value of 4.51 was determined.

나셀 변환 함수를 이용한 풍력터빈 출력성능평가 (Wind Turbine Power Performance Testing using Nacelle Transfer Function)

  • 김현우;고경남;허종철
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.51-58
    • /
    • 2013
  • A study on power performance testing of a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was carried out using the Nacelle Transfer Function, NTF, according to IEC 61400-12-2. The wind data for this study was measured at HanKyoung wind farm of Jeju Island. The NTF was modeled using the correlation between wind speeds from the met-mast and from the wind turbine nacelle within 2~4 rotor diameter from the met-mast. The NTF was verified by the comparison of estimated Annual Energy Productions, AEPs, and binned power curves. The Nacelle Power Curve, NPC, was derived from the nacelle wind speed data corrected by NTF. The NPC of wind turbine under test and the power curve offered by the turbine manufacturer were compared to check whether the wind turbine is properly generating electricity. Overall the NPC was in good agreement with the manufacturer's power curve. The result showed power performance testing for a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was successfully carried out in compliance with IEC 61400-12-2.

풍력발전기의 하중 측정을 위한 해석 소프트웨어의 개발 (Development of an Analysis Software for the Load Measurement of Wind Turbines)

  • 길계환;방제성;정진화
    • 풍력에너지저널
    • /
    • 제4권1호
    • /
    • pp.20-29
    • /
    • 2013
  • Load measurement, which is performed based on IEC 61400-13, consists of three stages: the stage of collecting huge amounts of load measurement data through a measurement campaign lasting for several months; the stage of processing the measured data, including data validation and classification; and the stage of analyzing the processed data through time series analysis, load statistics analysis, frequency analysis, load spectrum analysis, and equivalent load analysis. In this research, we pursued the development of an analysis software in MATLAB to save labor and to secure exact and consistent performance evaluation data in processing and analyzing load measurement data. The completed analysis software also includes the functions of processing and analyzing power performance measurement data in accordance with IEC 61400-12. The analysis software was effectively applied to process and analyse the load measurement data from a demonstration research for a 750 kW direct-drive wind turbine generator system (KBP-750D), performed at the Daegwanryeong Wind Turbine Demonstration Complex. This paper describes the details of the analysis software and its processing and analysis stages for load measurement data and presents the analysis results.

기술현황분석 - 풍력발전기 동적 시뮬레이션을 위한 NREL 프로그램군에 관한 소개 - 전처리기를 중심으로

  • 방제성;임채환;김재동
    • 기계와재료
    • /
    • 제23권4호
    • /
    • pp.74-83
    • /
    • 2011
  • 풍력발전기 동적 시뮬레이션 프로그램 개발을 위해 미국풍력기술연구센터(NWTC)의 프로그램군에 대해 분석하고 이를 소개하였다. 본 편에서는 에어포일 데이터를 생성하는 AirfoilPrep, IEC 61400-1 기준의 극한 조건에 해당하는 허브 높이의 바람 데이터를 생성하는 IECWind, 통계적인 방법에 의해 전 영역에 대한 난류 바람 데이터를 생성하는 TurbSim, 복합재료 블레이드의 구조적 특성치를 계산하는 PreComp, 블레이드와 타워의 모드 형상을 구하는 BModes와 같은 전처리기를 중심으로 설명하였다.

  • PDF

4MW급 풍력발전기용 요 감속기 설계 (Yaw Gearbox Design for 4MW Class Wind Turbine)

  • 이형우;김인환;이재신
    • 융합정보논문지
    • /
    • 제12권2호
    • /
    • pp.142-148
    • /
    • 2022
  • 본 논문은 풍력발전기용 요 감속기를 경량화하여 유한요소해석과 위험속도해석을 통해 안정성검증을 하였다. 제품의 경량화는 엔진의 효율을 높일 수 있으며, 부품의 소재를 절약하여 경제적 이득을 취할 수 있다. IEC 61400-1에서 제시한 풍력발전기 부품의 안전율 1.3이상을 목표로 풍력발전기용 요 감속기를 경량화하였다. 위상 최적화를 수행한 캐리어를 유한요소해석을 수행하여 안전율을 나타냈고, 하우징과 최적화한 캐리어를 MASTA11을 활용하여 작성한 풍력발전용 요 감속기 기어트레인 모델과 부분구조합성법으로 연결하여 고유 모드와 고유진 동수를 파악하여 질량불평형과 치통과 주파수에 대하여 위험속도해석을 수행하였고, 캠벨 선도(Campbell Diagram)를 작성하여 안정성 검증을 하였다.

Multi-MW급 풍력발전용 블레이드 설계에 관한 연구 Part I : 공력-구조 설계 및 통합하중해석 (Multi-MW Class Wind Turbine Blade Design Part I : Aero-Structure Design and Integrated Load Analysis)

  • 김범석
    • 대한기계학회논문집B
    • /
    • 제38권4호
    • /
    • pp.289-309
    • /
    • 2014
  • 풍력터빈 블레이드는 바람의 운동에너지를 기계적 에너지로 변환하는 장치로써 풍력발전시스템의 출력성능, 에너지변환효율, 하중 및 동적 안정성에 영향을 미칠 수 있기 때문에 주요부품으로 분류된다. 따라서 최적의 블레이드 설계결과를 얻기 위해서는 시스템 특성이 고려된 공력-구조 통합설계가 중요하다. 본 연구에서는 풍력터빈 시스템과의 상호작용이 고려된 블레이드 설계절차를 제안하였고, 2 MW 급 블레이드(KR40.1b)의 공력-구조 통합 설계결과를 제시하였다. 또한 전술한 바와 같이 로터 블레이드에 작용하는 극한하중 및 피로하중은 시스템 운전조건에 따라 가변적이므로 시스템통합하중해석을 위한 2 MW 풍력발전시스템 모델링을 수행하였으며, IEC 61400-1 및 (사)한국선급의 풍력발전기술기준에 따라 수행된 하중해석결과를 제시하였다.

1.5kW급 풍력발전기용 블레이드의 구조해석 및 구조시험 (Structural Analysis and Testing of 1.5kW Class Wind Turbine Blade)

  • 김홍관;이장호;장세명;강기원
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.51-57
    • /
    • 2010
  • This paper describes the structural design and testing for 1.5kW class wind turbine composite blade. In order to calculate the equivalent material properties rule-of-mixture is applied. Lay-up sequence, ply thickness and ply angle are designed to satisfy the requirements for structural integrity. Structural analysis by using commercial software ABAQUS is performed to assess the static, buckling and vibration response. And to verify the structural analysis and design, the full scale structural test in flapwise direction was performed under single point loading according to loading conditions calculated by the aerodynamic analysis and Case H (Parked wind loading) in IEC 61400-2.