Calcite Production by Bacillus amyloliquefaciens CMB01

  • Lee, Young-Nam
    • Journal of Microbiology
    • /
    • v.41 no.4
    • /
    • pp.345-348
    • /
    • 2003
  • The bio-mediated production of calcite crystals by calcinogenic bacteria has great applicable value for the restoration of deteriorated calcareous monuments, because of its high purity and coherency. An investigation of the conditions for calcite production by an alkalophilic Bacillus amyloliquefaciens CMB01 strain was made. Optimal calcite precipitation occurred when the bacterium was cultured at pH 8.0 and 30$^{\circ}C$, and in B4 medium that consisted of 0.4% yeast extract, 0.5% glucose, and 1.5% calcium acetate. Calcium ion of the bacterially induced calcite was analyzed by an inductively coupled plasma (ICP) spectrophotometer. Optical and scanning electron microscopy (SEM) of the calcite revealed a typical rombohedral polycrystalline structure.

Elemental Analysis of Drinking Water with ICP/AES (ICP/AES에 의한 먹는물의 무기원소 분석)

  • Park, Kye-Hun;Shin, Hyung-Seon;Han, Cheong-Hee
    • Economic and Environmental Geology
    • /
    • v.29 no.1
    • /
    • pp.21-24
    • /
    • 1996
  • Inductively coupled plasma atomic emission spectrophotometer (ICP/AES) is a versatile modern instruments for the multi-element analysis, but quantitative analysis using ICP/AES with normal pneumatic nebulizer is not applicable for the measurement of elemental concentrations in water down to the drinkining water standard level except a few elements because of poor detection limits. However, the detection limit can be lowered enough to measure drinking water standard, if ultrasonic nebulizer and/or hydride vapor generator is attached. This method is tested with groundwater samples from Tajeon area. It is confirmed that the elemental concentrations in these samples are within the limit of drinking water standard for the most elements. However, uranium concentration is very high in some samples compared with the concentrations suggested by Environmental Protection Agency of U.S.A. There is no standard concentration level to this element in Korea and it should be prepared immediately.

  • PDF

Low Temperature Deposition of ITO Thin Films for Flat Panel Displays by ICP Assisted DC Magnetron Sputtering (유도결합 플라즈마(ICP) Sputtering에 의한 평판 디스플레이(FPD)용 ITO 박막의 저온 증착)

  • 구범모;정승재;한영훈;이정중;주정훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.3
    • /
    • pp.146-151
    • /
    • 2004
  • Indium tin oxide (ITO) is widely used to make a transparent conducting film for various display devices and opto-electric devices. In this study, ITO films on glass substrate were fabricated by inductively coupled plasma (ICP) assisted dc magnetron sputtering. A two-turn rf coil was inserted in the process chamber between the substrate and magnetron for the generation of ICP. The substrates were not heated intentionally. Subsequent post-annealing treatment for as-deposited ITO films was not performed. Low-temperature deposition technique is required for ITO films to be used with heat sensitive plastic substrates, such as the polycarbonate and acrylic substrates used in LCD devices. The surface roughness of the ITO films is also an important feature in the application of OLEDs along with the use of a low temperature deposition technique. In order to obtain optimum ITO thin film properties at low temperature, the depositions were carried out at different condition in changing of Ar and $O_2$ gas mixtures, ICP power. The electrical, optical and structural properties of the deposited films were characterized by four-point probe, UV/VIS spectrophotometer, atomic force microscopy(AFM) and x-ray diffraction (XRD). The electrical resistivity of the films was -l0$^{-4}$ $\Omega$cm and the optical transmittance in the visible range was >85%. The surface roughness ( $R_{rms}$) was -20$\AA$.>.

Determination of Heavy Metals Concentrations in Urban Air using ICP Method : in the Area of Chung-Ang University (ICP법에 의한 도시대기중 중금속 농도 측정: 중앙대학교를 중심으로)

  • 손동헌;신혜숙;정성윤;정원태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.222-229
    • /
    • 1993
  • Total suspended particles in the atmosphere were collected on the quartz fiber filters using an ANdersen Hi-volume air sampler from March 1989 to October 1989 and from June 1990 to February 1991, at Chung-Ang University in Seoul. A total amount of eight heavy metals (Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) in total suspended particles were determined by ICP spectrophotometer. The annual arithmetic mean concentration of total suspended particle was 162.3$\mug/m^3$ and eight metals(Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) were 11.6, 609.2, 3.5, 337.1, 2739.5, 15.1, 89.4 and 100.5ng/$m^3$, respectively. The concentration of total suspended particle was highest in the spring(343.7$\mug/m^3$) and lowest in the summer(91.8$\mug/m^3$). These heavy metals were distinguished into two groups in terms of their particle size distribution. The contents of first-group heavy metals (Fe, Ti, Mn) were increased in accordance with the growth of the particle size. The contents of the second-group ones such as Pb, Cd, V, and Zn, on the contrary, came to increase according as the particle size reduced. Statistical analysis indicated that there was a correlation between total suspended particle and Fe in coarse particles, and between total Suspended Particle and Zn, Pb in fine particle.

  • PDF

A Study on the Environmental Radioactive Strontium Analysis (환경중 방사성 스트론튬 분석 방법 연구)

  • Lee, Goung-Jin;Hwang, Jung-Lae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.155-160
    • /
    • 1999
  • In the natural, there exist several kinds of radioactive isotopes. From atmospheric weapon tests and then some isotopes are naturally radioactivity above all things, nuclear power plant operation and man-made radioactive isotopes concern steadily growing in the environment. During the fission process of nuclear weapon tests and nuclear power plant operation, more than 200 radioactive isotopes are generated. Among them, $^{90}Sr$ and $^{137}Cs$ has been regarded as very important isotopes due to characteristics. In this paper, a quantitative analysis method of environment low level $^{90}Sr$ is studied. Radioactivity level of the environmental $^{90}Sr$ is very low, and it emits continuous beta spectrum, and $^{90}Sr$ exists together with $^{89}Sr$, $^{90}Y$ and other radioactive isotopes. It very difficult to make the quantitative analysis of $^{90}Sr$. For the analysis of low level radioactive strontium, enrich and chemical separation of strontium from the other radioactive isotopes are needed. For the estimation of strontium recovery ratio, so called SGAT(Strontium Gravimetric Analysis Technique) was generally used among the domestic research groups, and chemical procedures were developed appropriation for the SGAT, Recently, by using ICP(Inductively Coupled atomic Plasma emission spectrophotometer), amounts of stable atoms can be measured easily and accurately to the extend of ppm or ppb. In this paper, new chemical procedures are developed to exploits the ICP technique. New developed method has simpler chemical treatment procedures and then it gives more accurate results compared with the traditional SGAT.

  • PDF

Physical and Chemical Characteristics of Waste Automotive Catalysts (자동차 폐촉매의 물리 화학적 특성)

  • Seo, Seong-Gyu;Moon, Joung-Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.819-825
    • /
    • 2000
  • The physico-chemical characteristics and the combustion activities of a waste automotive catalyst were carried out in this study. The physico-chemical characteristics of waste automotive catalyst was examined by EA(Elemental analysis), ICP-AES (Inductively coupled plasma-atomic emission spectrophotometer), and XRD(X-ray diffraction) analysis. Carbon deposit amount was higher in front brick than rear brick of catalyst, and increased with mileage. The content of Pt. Pd and Rh in waste automotive catalyst was different from the car manufacturing company. The combustion activities of waste automotive catalyst were investigated for acetaldehyde as a model VOC in a fixed bed reactor at atmospheric pressure. The catalytic activity of rear brick for acetaldehyde combustion was better than front brick of waste automotive catalyst. The catalytic activity of waste automotive catalyst for acetaldehyde combustion decreased with mileage. The linear relationship between catalytic activity and mileage was negative and has a very excellent correlation. Finally, the waste automotive catalyst has a good catalytic activity for acetaldehyde combustion. and can be used to control of small emission source.

  • PDF

Au 나노 입자 마스크를 이용한 실리콘 반사방지막 제작

  • Im, Jeong-U;Yu, Jae-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.240-240
    • /
    • 2010
  • 반사 방지막은 LEDs, 태양전지, 센서 등의 광전소자의 효율을 향상시키는데 사용되고 있다. 일반적으로 사용되는 단층 또는 다층 박막의 반사방지막은 thermal expansion mismatch, adhesion, stability 등의 문제점을 가지고 있다. 따라서, 단층 또는 다층 박막의 반사방지막 대신에 파장이하의 주기를 갖는 구조(subwavelength structure, SWS)의 반사방지막 연구가 활발히 진행되고 있다. 입사되는 태양 스펙트럼의 파장보다 작은 주기를 갖는 SWS 구조는 Fresnel 반사율을 감소시켜 빛의 손실을 줄일 수 있다. 이러한 SWS 반사 방지막을 제작하기 위해서는 에칭 마스크가 필요하다. 에칭 마스크 제작을 위해서 사용되는 장비로는 홀로그램, 전자빔, 나노임프린트와 같은 리소그라피 방법이 있으나, 이들은 제작 비용이 고가이며 복잡한 기술을 필요로 한다. 따라서 본 실험에서는 리소그라피 방법보다 간단하고 저렴한 self-assembled Au 나노 입자 에칭 마스크를 이용한 실리콘 SWS 반사 방지막을 제작하여 구조적 및 광학적 특성을 연구하였다. Au박막은 열증발증착(thermal evaporator)법에 의해 실리콘 기판 위에 증착되었고, 급속 열처리(rapid thermal annealing, RTA)를 통해 Au 나노입자 에칭 마스크를 형성시켰다. 실리콘 SWS 반사방지막은 식각 가스 $SiCl_4$를 기반의 유도결합 플라즈마(inductively coupled plasma, ICP) 장비를 사용하여 제작되었다. Au 나노 입자의 마스크 패턴 및 에칭된 실리콘 SWS 프로파일은 scanning electron microscope를 사용하여 관찰하였으며, UV-Vis-NIR spectrophotometer를 사용하여 300-1100 nm 파장 영역에 따른 반사율을 측정하였다. ICP 에칭 조건을 변화시켜 가장 낮은 반사율을 갖는 최적화된 실리콘 SWS 반사방지막을 도출하였다. 최적화된 구조에 대해서, 실리콘 SWS 반사방지막은 벌크 실리콘 (>35%)보다 더 낮은 5% 이하의 반사율을 나타냈다.

  • PDF

Determination of Hazardous Metals in Nail Enamel Containing Glitter (글리터를 포함한 네일 에나멜 제품의 유해 금속 분석)

  • Ko, Suk Kyung;Chung, Sam Ju;Park, Young Hye;Park, Ae Sook;Kim, Hyun Jung;Park, Geon Yong;Oh, Young Hee
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.103-110
    • /
    • 2017
  • Objectives: This study was performed to provide basic data for the re-establishment of standards (criteria) and analytical methods for hazardous metals in nail enamel. Methods: Ten metals (lead; Pb, arsenic; As, cadminum; Cd, antimony: Sb, cobalt; Co, nikel; Ni, copper; Cu, chromium; Cr, aluminum; Al, and mercury; Hg) were measured in 67 commercial nail enamels containing glitter and/or pearls. The content of hazardous metals (excepting Hg) was determined by using an inductively coupled plasma-optical emission spectrophotometer (ICP-OES) after microwave digestion. Mercury content was measured by a mercury analyzer without any preparation. Results: The detected ranges of the intact samples were as follows: $ND-1.756{\mu}g/g$ for Pb, $ND-1.24{\mu}g/g$ for As, ND for Cd, $ND-20.41{\mu}g/g$ for Sb, $ND-12.36{\mu}g/g$ for Co, $ND-7.908{\mu}g/g$ for Ni, $0.088-79.27{\mu}g/g$ for Cu, $0.281-18.54{\mu}g/g$ for Cr, $13.78-3563{\mu}g/g$ for Al, and $ND-0.044{\mu}g/g$ for Hg. After centrifugation, the detected ranges of supernatant were as follows: $ND-0.435{\mu}g/g$ for Pb, $ND-0.504{\mu}g/g$ for As, ND for Cd, $ND-0.035{\mu}g/g$ for Sb, $ND-13.17{\mu}g/g$ for Co, $ND-0.232{\mu}g/g$ for Ni, $0.117-90.07{\mu}g/g$ for Cu, $0.174-2.787{\mu}g/g$ for Cr, and $9.459-1565{\mu}g/g$ for Al. The results of this analysis showed that the levels of heavy metals such as Pb, As, and Sb were much higher in the intact samples than those of supernatant. Conclusion: In the present study, we found that the levels of hazardous metals were significantly different depending on the status of the presence of glitter. Based on the results, we recommend that the product consumer refrain from prolonged application of nail enamel, avoid biting or chewing the nails, and wear gloves during cooking and washing dishes.

Potential Antioxidant Trace Mineral (Zn, Mn, Cu and Fe) Concentrations Measured by Biochemical Indices in South Koreans

  • Cho, Young-Eun;Byun, Young-Mee;Kwak, Eun-Hee;Yoon, Jin-Sook;Oh, Hyun-Mee;Kim, Jae-Wang;Shin, Hyun-Soo;Kwon, Chong-Suk;Kwun, In-Sook
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.4
    • /
    • pp.374-382
    • /
    • 2004
  • The concern of the antioxidant micronutrient status in normal healthy people, including antioxidant trace minerals such as Cu, Zn, Mn, Fe and Se is focused since systemic oxidation is involved in various chronic diseases. In the present study, we evaluated the concentration of trace minerals (Cu, Zn, Mn, and Fe) which are considered as potential antioxidant minerals in plasma, red blood cells (RBCs) and urine in normal healthy Korean subjects. The 760 subjects (male 341, female 419; mean age 54.2 $\pm$ 18.9) were recruited from the rural, urban and metropolitan city in South Korea. Dietary intake was evaluated using 24-hours recall for general major nutrient intake assessment. The trace elements (Cu, Zn, Mn, and Fe) concentrations in plasma, RBCs, and urine were measured by inductively coupled plasma spectrophotometer (ICP) and atomic absorption spectrophotometer (AAS). Cu and Zn levels in plasma, RBCs and urine in normal healthy South Koreans were within the normal range of those mineral levels, but Mn and Fe levels were higher compared to the normal range of those mineral levels. None of the selected trace mineral levels in plasma and RBC's was lower than the normal range value. The results showed that Zn and Cu levels in plasma and RBC's in Korean were within the normal range, and plasma and urinary Mn and Fe levels were higher than the normal reference values. Potential antioxidant trace mineral (Cu, Mn, Zn and Fe) levels in Koreans are within or a bit higher than the normal range.

Contents of Toxic Metals in Fruits Available on Korean Markets (국내유통 과일류 중 유해중금속 함량)

  • Kim, Mee-Hye;Kim, Jung-Soo;Sho, You-Sub;Chung, So-Young;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.523-526
    • /
    • 2004
  • There are few studies on toxic metals in fruits. Therefore, we examined contents of toxic metals in fruits (n=386) available in Korean markets. The samples were digested with acids, then analyzed by inductively coupled plasma spectrometer (ICP) or atomic absorption spectrophotometer (AAS) for lead (Pb), cadmium (Cd), and arsenic (As). The contents of mercury (Hg) were also determined using a mercury analyzer, Contents of toxic metals in fruits were as follows [minimum-maximum (mean), mg/kg]; Hg 0.0001-0.019 (0.001), Pb 0.001-0.410 (0.013), Cd 0.001-0.035 (0.000), and As 0.001-0.210 (0.017). Our results showed that metal contents in fruits in Korean markets were similar to those reported in other countries. Average weekly intakes of Hg, Pb, and Cd from fruits are about 1-2% of Provisional Tolerable Weekly Intakes (PTWI) set by FAO/WHO Joint Food Additive and Contaminants Committee for safety evaluation.