• Title/Summary/Keyword: ICP monitoring

Search Result 102, Processing Time 0.027 seconds

Road Dust Emissions from Paved Roads Measured by Road Dust Monitoring Vehicle and Analysis of Trace Elements (도로 재비산먼지 이동측정차량을 이용한 도로 재비산먼지 측정과 도로먼지 미량원소 분석)

  • Lee, Myung-Hwoon;Shin, Jung-Sub;Shin, Won-Geun;Lee, Sang-Gu;Kim, Cheong;Lee, Chang
    • Particle and aerosol research
    • /
    • v.8 no.2
    • /
    • pp.47-54
    • /
    • 2012
  • Paved road dust emissions were investigated 14 times on 12 main roads in Seo-Cho Gu, Seoul, Korea by vehicle-based mobile sampling system(Road Dust Monitoring System) during September to December 2011. Also, fourteen heavy metals present in the dust samples were analyzed by ICP. ICP analysis showed that one of major source of the road dust would be urban construction. A large amount of silt was found, which might be originated mainly from building construction and open beds of trees. Trace element and pollution indices of heavy metals(Cd, Cu, Ni, Pb, Zn) on the roads adjacent to the commercial area had higher concentrations than those on the roads adjacent to the construction and residential areas because of traffic density and heavy traffic.

Comparison Between Performance of a Wireless MEMS Sensor and an ICP Sensor in Shaking Table Tests (진동대를 이용한 무선 MEMS 센서와 ICP 가속도계의 성능 비교)

  • Mapungwana, S.T.;Jung, Young-Seok;Lee, Jong-Ho;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.49-59
    • /
    • 2018
  • Wireless sensors are more favorable in measuring structural response compared to conventional sensors. This is because they are easier to use with no issues with cables and are considerably cheaper. There are several applications that can be used in recording and analyzing data from MEMS sensor installed on an iPhone. The Vibration App is one of the applications used and there has not been adequate research conducted in analyzing the performance of this App. This paper analyzed the performance of the Vibration App by comparing it with the performance of an ICP sensor. Results show that natural frequency results are more accurate (error less than 5%) in comparison to the amplitude results. This means that built- in MEMS sensor in smartphones are good at estimating natural frequency of structures. In addition, it was seen that the results became more accurate at higher frequencies (5.0Hz and 10.0Hz).

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

Intracranial Pressure and Cerebral Blood Flow Monitoring after Bilateral Decompressive Craniectomy in Patients with Acute Massive Brain Swelling (급성 중증 뇌종창 환자의 양측성 감압개두술 후 뇌압 및 뇌혈류 측정)

  • Yoo, Do-Sung;Kim, Dal-Soo;Huh, Pil-Woo;Cho, Kyoung-Suck;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.295-306
    • /
    • 2001
  • Objectives : The management of massive brain swelling remains an unsolved problem in neurosurgical field. Despite newly developed medical and pharmacological therapy, the mortality and morbidity due to massive brain swelling remains high. According to many recent reports, surgical decompression with dura expansion is superior to medical management in patients with massive brain swelling. We performed surgical treatment on the first line of treatment, and followed medical management in case with refractory increased intracranial pressure(ICP). To show the quantitative effect of decompressive surgery on the intracranial pressure, we performed ventricular puncture and checked the ventricular ICP continuously during the decompressive surgery and postoperative period. Materials and Methods : Fifty-one patients with massive brain swelling, undergoing bilateral decompressive craniectomy with dura expansion, were studied in this study. In all patients, ventricular puncture was performed at Kocher's point on the opposite side of massive brain swelling. The ventricular pressure was monitored continuously, during the bilateral decompression procedures and postoperative period. Results : The initial ventricular ICP were varied from 13mmHg to 112mmHg. Immediately after the bilateral craniectomy, mean ventricular ICP decreased to $53.1{\pm}15.8%$ of the initial ICP(ranges from 5mmHg to 87mmHg). Dura opening decreased mean ICP by additional 36.7% and made the ventricular pressure $16.4{\pm}10.5%$ of the initial pressure (ranges from 0mmHg to 28mmHg). Postoperatively, ventricular pressure was lowered to $20.2{\pm}22.6%$(ranged from 0mmHg to 62.3mmHg) of the initial ICP. The ventricular ICP value during the first 24 hours after decompressive surgery was found to be an important prognostic factor. If ICP was over 35mmHg, the mortality was 100% instead of additional medical(barbiturate coma therapy and hypothermia) treatments. Conclusion : Bilateral decompression with dura expansion is considered an effective therapeutic modality in ICP control. To obtain favorable clinical outcome in patients with massive brain swelling, early decision making on surgical management and proper patient selection are mandatory.

  • PDF

The effect on the Intracranial Pressure of the Patients Receiving Endotracheal Suction (기관내 흡인이 두개강내압에 미치는 영향에 관한 연구)

  • 김매자;이경옥
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.2
    • /
    • pp.245-254
    • /
    • 1993
  • The purpose of this study was to identify effective methods to minimize increases in intracranial pressure(IICP ) during endotracheal suction by means of comparing two methods of hyperventilation and oxygen supply before and after endotracheal suction. In order to evaluate the effects of these two methods, the ICP during suctioning and the sustained time of IICP were measured. For hyperventilation, ambu-bagging was done 10 times for 30 seconds with a tidal volume of 800-900m1. For oxygen supply, 100 percent oxygen was supplied for 2 minutes before and after suction. The subjects for this study were 12 neurosurgical patients who had had a subarachnoid bolt inserted for ICP monitoring and they were all on mechanical ventilatory support in a surgical intensive care unit of Seoul National University Hospital from July 1, 1991 to March 31, 1992. In each patient hyperventilation was performed five times and oxygen supply was given five times and intracranial pressures were measured immediately before and every 30 seconds for 15 minutes after suction. For case assignments counterbalancing and repeated measure designs were combined. And so the total number of experiments were sixty for each group. The effects of hyperventilation and oxygen supply on the IICP and the sustained time of IICP after suction were analyzed by t-test. The results of study were as follows 1. There was a significant difference between the two groups in the increased ICP during suction (t=2.49, p=.014). 2. The sustained time of IICP after suctioning in the oxygen supply group was shorter than that in the hyperventilation group(t=2.35, p=.020) In summary, the Increase in the ICP during suction was lower and the time for the ICP to return to the presuction level was shorter in the oxygen supply group as compared to the hyperventilation group. Therefore, oxygen supply can be re commended before and after endotracheal suction.

  • PDF

Establishing of a rapid analytical method on uranium isotopic ratios for the environmental monitoring around nuclear facilities (원자력 시설 주변 환경 감시를 위한 토양 중 우라늄 동위원소 신속 분석법 확립)

  • Park, Ji-Young;Lim, Jong-Myoung;Lee, Hyun-Woo;Lee, Wanno
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.134-142
    • /
    • 2018
  • The uranium isotopic ratio in environmental samples around nuclear facilities is important because it reveals information regarding illegal activities or anthropogenic pollution. Determination of uranium isotopes, however, is a challenging task requiring much labor and time because of the complex separation procedures and lengthy process. In this study, a rapid determination method for uranium isotopes in environmental samples was developed using. The sample was completely decomposed using the alkali fusion method. The separation procedure using extraction chromatography (UTEVA) was simplified in a single step without any further removal process for Si and major matrix elements. The established method can be completed within 3 h from sample dissolution to ICP-MS measurement. Most matrix elements and uranium isotopes in the soil samples were well separated and purified. Five types of were used to assess the method's accuracy and precision for a rapid uranium analysis method. The analytical accuracy for all CRM samples ranged from 95.1 % to 97.8 %, and the relative standard deviation was below 3.9 %. From the analytical results, one may draw conclusions that the evaluated method for uranium isotopes using alkali-fusion, the extraction chromatography process, and ICP-MS measurements is fast and fairly reliable owing to its recovering efficiencies. Thus, it is expected that the evaluated method can contribute to the improvement of environmental monitoring ability.

Multielement Analysis in Airborne Particulate Matter $(PM_{10})$ by INAA, ICP and AAS (INAA.ICP.AAS를 이용한 대기먼지 $(PM_{10})$의 다원소분석)

  • 정용삼;문종화;정영주;박광원;이길용;윤윤열;심상권;조경행;한명섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.495-503
    • /
    • 1999
  • Airborne particulate matter $(PM_{10})$ collected using high volume air sampler and silica fiber filter were analyzed by Instrumental Neutron Activation Analysis(INAA), Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES) and Atomic Absorption Spectrometry(AAS), and the results were compared with each other. 30~40 trace elements in environmental standard reference materials(NIST SRM 1648 and NIES CRM No.8) were analyzed for the analytical quality control. The relative error for two-third of elements detected was less than 10%, and the standard deviation was less than 15%. During the sampling period for 24 hours, the mass concentration of total suspended particulate was 36.1$\mu\textrm{g}$/㎥ and the value is lower than the critical level in Korea. In the results of NAA, the elements of Al, As, Ba, Fe, La, Mg, Na, Sb, Zn were well agreed with those of other methods. In statistical estimation between different methods, the deviation of Al, Ba, Cr, Fe was less than 10% and quite reliable.

  • PDF

A Real-Time Diagnostic Study of MgO Thin Film Deposition Process by ICP Magnetron Sputtering Method (MgO 증착을 위한 유도결합 플라즈마 마그네트론 스퍼터링에서 실시간 공정 진단)

  • Joo Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.2
    • /
    • pp.73-78
    • /
    • 2005
  • A real-time monitoring of ICP(inductively coupled plasma) assisted magnetron sputtering of MgO was carried out using a QMS(quadrupole mass spectrometer), an OES(optical emission spectrometer), and a digital oscilloscope with a high voltage probe and a current monitor. At the time of ICP ignition, the most distinct impurity was OH emission (308.9 nm) which was dissociated from water molecules. For reactive deposition oxygen was added to Ar and the OH emission intensity was reduced abruptly When the discharge voltage was regulated by a PID controller from 240V(metallic mode) to 120V(oxide mode), the emission intensity from Mg (285.2 nm) changed proportionally to the discharge voltage, but the intensity of Ar I(811.6 nm) was constant. At 100V of discharge voltage, Mg sputtering was almost stopped. Emissions from Ar I(420.1 nm) and Mg I were dropped down to 1/10, but Ar I(811.6 nm) didn't change. And the emission from atomic oxygen (O I, 777.3 nm) was increased to 10 times. These results are compatible with those from QMS study.

Measurement of heavy metals in antarctic soil at the king sejong station: application of isotope dilution inductively coupled plasma mass spectrometry (동위원소희석 ICP-MS분석법에 의한 남극 세종기지 주변 토양의 중금속 측정)

  • Suh, Jung-Ki;Hwang, Euijin;Min, Hyung Sik
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.364-374
    • /
    • 2008
  • Antarctic Environmental Monitoring Handbook' was published by COMNAP/SCAR in 2000. The standardized method described in this handbook is recommended for monitoring of antarctic environment. High pressure bomb technique in this guide was used to decompose soil samples. In compliance with this guide book, high pressure bomb technique was applied to decompose the antarctic soil sampled at the King Sejong Station. An Isotope Dilution-Inductively Coupled Plasma-Mass Spectrometry (ID-ICP-MS) was applied to determine mass concentrations of Pb, Cu and Zn in the soil. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of NIST 2702 (marine sediment). The analytical results agreed with certified value within the range from 99.5~100.8%. Matrix separation was necessitated for the determination of Cu and Zn by Chelex 100 ion exchange resin. As a result, the average mass concentrations of Pb, Cu and Zn which are suspected to be caused by anthropogenic pollution were 332.9 mg/kg, 95.6 mg/kg and 115.3 mg/kg, respectively. Those for the metals sampled in the soils of the remote regions from the station were 28.1 mg/kg, 101.8 mg/kg and 115.6 mg/kg, respectively.

Cu Ions Removal Using Graphene Oxide and in-situ Spectroscopic Monitoring Method of Residual Cu Ions (산화 그래핀을 이용한 구리이온 흡착과 투과도 특성을 이용한 구리이온 농도 실시간 측정)

  • Kim, Seungdu;Ryou, Heejoong;Oh, Hoon-Jung;Hwang, Wan Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.2
    • /
    • pp.87-91
    • /
    • 2021
  • Various Cu ions are discharged into water from various industries, which results in a severe trouble for groundwater, soil, air, and eventually animals and humans. In this work, graphene oxide (GO) is introduced as a Cu removal absorber and the real-time monitoring method is demonstrated. The results show that GO is a very effective material to absorb Cu ions in the solution. In addition, the residual Cu ions in the solution is monitored via optical transmittance method, which well match with Inductively Coupled Plasma Mass Spectrometer (ICP-MS) analysis.