• Title/Summary/Keyword: ICNIRP

Search Result 32, Processing Time 0.159 seconds

A Study on High Current Rectifier Systems with Mitigated Time-Varying Magnetic Field Generation

  • Kim, Chang-Woo;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.232-233
    • /
    • 2010
  • This paper investigates occupational exposure to time-varying magnetic field generation in high power rectifier systems. Two different kinds of high power rectifier systems of 25kA are modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. In order to focus on the qualitative effect of rectifier operation, the mechanical structure of current carrying conductors is simplified as infinite long bus-bar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc side of rectifier infringing the limit from ICNIRP. The multilevel rectifier-IGCT type has almost negligible field generation from ac input side and smaller harmonic contents in dc load side complying with ICNIRP guideline. This remarkable advantage of multilevel rectifier-IGCT type can lead to very simple site layout design for installation and cost-effective compliance to guideline of occupational exposure against magnetic field.

  • PDF

Guidelines of IRPA/ICNIRP for Non-ionizing Radiation (비이온화방사선에 대한 IRPA/ICNIRP의 제반지침)

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.3
    • /
    • pp.143-154
    • /
    • 1995
  • In recent years, the development of new technologies using static magnetic fields has increased the possibility of human exposure to these fields and raised some concern as to their possible health effects. In several countries, governmental or other competent authorities have issued exposure limits that are mainly intended for specific uses, i.e., magnetic resonance imaging (MRI) and particle accelerators for high-energy Physics. Since applications of magnetic fields in industry and medicine are likely to grow in the future, thus increasing the possibility of occupational and general public exposure, and since the number of people with ferromagnetic implants and implanted electronic devices that can be affected by the fields is growing, there is a need for international guidelines. In the present papers, guidelines on limits of exposure to static magnetic fields are selected and discussed in order to review the guidelines of the International Non-ionizing Radiation Committee of the International Radiation Protection Association (IRPA/INIRC) for non-ionizing radiation(NIR)

  • PDF

Analyses on Current Densities Induced Inside a Worker Using AC Arc Welder (교류 아크용접기를 사용하는 작업자의 인체 유도전류밀도 해석)

  • Park, Jun-Hyeong;Min, Suk-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.433-438
    • /
    • 2008
  • This paper analyses current densities induced inside a worker using AC arc welder. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1cm, 3cm, 5cm, 10cm, 15cm, 20cm far from a power cable of AC arc welder. As results of study, we find a maximum current density induces at a heart surface and may be higher than $10mA/m^2$ of ICNIRP guideline if he works within 15cm from a power cable.

Analysis of Safety Distance and Maximum Permissible Power of Resonant Wireless Power Transfer Systems with Regard to Magnetic Field Exposure

  • Park, Young-Min;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.450-459
    • /
    • 2015
  • In this paper, the safety distances and maximum permissible power (MPP) of resonant wireless power transfer systems are defined and derived with regard to human exposure to electromagnetic field (EMF). The definition is based on the calculated induced current density and electric field in the standard human model located between the transmitting and receiving coil. In order to avoid the adverse health effects such as stimulation of nerve tissues, the induced current and electric field must not exceed the basic restriction values specified in EMF safety guidelines. The different combinations of diameters of the coils and the distance between the two coils are investigated and their effects are analyzed. Two versions of EMF safety guidelines (ICNIRP 1998 and ICNIRP 2010) are used as bases for safety distance calculation and the difference between the two guidelines are discussed.

Characteristics of Time Varying Magnetic Fields in Thyristor Rectifiers of 19kA in Chlor-Alkali Industry

  • Shirmohammadi, Siamak;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.383-384
    • /
    • 2014
  • This paper investigates the experimental and simulated time-varying magnetic field generation in a chlor-alkali manufacturing process. 19kA thyristor-based rectifier is modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. The mechanical structure of current carrying conductor is simplified as an infinite long busbar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc busbar of rectifier infringing the limit of ICNIRP. Along with simulation analysis the experimental measurement of the time-varying magnetic field in ac input busbar, rectifier block, dc load and busbar are presented. The experimental test results partly confirm the simulation results.

  • PDF

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline (공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석)

  • Shin, Hansu;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

Analysis of Human Exposure for Wireless Devices Near War-Fighter (전투원 신체 주변 통신기기의 인체 노출량 분석)

  • Seo, Min-Gyeong;Choi, Jeung-Won;Ko, Jong Hwan;Lee, Hyunsung;Park, Juman;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.106-112
    • /
    • 2013
  • In this paper, human exposure of wireless devices was analyzed for various positions of the transmitter. The scenario for the position of the transmitting antenna was decided after discussion with ADD(Agency for Defense Development), and Korean male phantom model developed by ETRI were used to conduct simulations. The SAR values were analyzed by changing the position of the transmitter, and compared with Korean EMF regulations and ICNIRP guidelines. Additionally, human exposure was also investigated for two typical postures which can be posed by war-fighter.

ELF Electric Field Calculation of High Speed Railway Using Boundary Element Method (경계분할법을 이용한 고속철도 주변의 극저주파 전계 예측계산)

  • Myung, Sung-Ho;Lee, Jae-Bok;Kim, Jeom-Sik;Kim, Eung-Sik;Lee, Jong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.29-31
    • /
    • 2001
  • 본 논문에서는 고속철도 주변의 상용주파수(60 Hz) 대역의 전계 해석에 촛점을 두고 경계분할법의 일종인 전하중첩법과 표면전하법을 사용하여 선로주변의 전계 계산을 수행하였다. 계산 결과 지상 1m 열차 플랫폼 주변에서의 전계값은 0.5kV/m 이하로써 국제비전리방사보호위원회 (ICNIRP)의 권고 기준인 4.167kV/m를 충분히 만족함을 알 수 있었으며 사용자 편의를 위해 전계 해석용 프로그램을 윈도우 환경하에서 MFC를 이용하여 개발하였다.

  • PDF

ELF Magnetic Field Calculation of High Speed Railway According to Condition of Train Operation (열차 운행조건에 따른 고속철도 주변의 극저주파 자기장 예측계산)

  • Myung, Sung-Ho;Lee, Jae-Bok;Kim, Jeom-Sik;Kim, Eung-Sik;Lee, Jong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.231-233
    • /
    • 2001
  • 본 논문에서는 고속철도 급전계통 주변에서 여러가지 운전 조건하의 자계를 예측 계산하였다. 여기에서는 자계해석 방법으로 Biot Savart's law에 기반을 둔 해석식을 사용하였으며 대지 귀환회로를 계산과정에 포함하여 실제에 가까운 모델링을 하였다. 계산결과 열차 주변 지상 1m 부근의 플랫폼에서 자계의 크기그하였으며, 국제비전리방사보호위원회(ICNIRP)의 자기장 권고기준과 비교하여 평가하였다.

  • PDF