• Title/Summary/Keyword: ICD

Search Result 253, Processing Time 0.033 seconds

Integrated Communication Design Strategies for the Revised Marketing Environment (마케팅환경 변화에 따른 통합커뮤니케이션디자인 전략)

  • Yang, Jae-Bum
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.5
    • /
    • pp.113-121
    • /
    • 2008
  • Researcher tried to argue the possibility of application of visual communication design adapting the marketing environment change on this paper. What is ICD (Integrated Communication Design)? This is a new attempt to treat these common marketing methods, such as, C, I, B, I, TV commercials, newspaper commercials, posters, brochures, DM, package designing, POP, outdoor visual information, web sites etc, as a whole. And no longer treat them as separate pieces as we were doing previously. So I started this research with positive analysis which already has been theoretically discussed based on the documents and researches on the same subject. Through this attempt I tried to examine the possibility of application of ICD. Conclusively, I developed and suggest named the ICD model, by which we could explain the current marketing communication design effort more holistically then ever.

The Extent of Intellectual Capital Disclosure and Corporate Governance Mechanism to Increase Market Value

  • SOLIKHAH, Badingatus;WAHYUDIN, Agus;RAHMAYANTI, Anggraeni Anisa Wara
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.119-128
    • /
    • 2020
  • The aim of this paper is to investigate the level of intellectual capital disclosure (ICD) in commercial banks listed on the Indonesian Stock Exchange. This paper also observed the effects of ICD and corporate governance mechanism on market value. This study uses content analysis techniques to measure ICD. The paper provides a novel approach to measure the ICD quality in developing countries using a four-numerical coding system. Secondary data were obtained from the financial statements and annual reports of the banks for the period 2011-2014. The data from 31 banks were analyzed using ordinary least square regression. The study reports that the quality of intellectual capital disclosure in Indonesian commercial banks increase steadily. Narrative disclosure dominates the report of intellectual capital in Indonesian banks. The results indicate that the size of audit committee, frequency of audit committee meeting, and intellectual capital disclosure affect positively the market value. Overall, the results indicate intellectual capital disclosure is associated with the market capitalization; these findings indicate that the ICD is a consideration in a stock investment decision. While regulations in Indonesia regarding intellectual capital reporting are not conclusive yet, the information needs of stakeholders have encouraged companies to expand voluntary disclosure.

Intrapericardial Implantation of an Implantable Cardioverter-Defibrillator in a Child

  • Seong, Yong-Won;Kim, Woong-Han;Yoo, Jae-Suk;Kim, Hye-Seon;Min, Byoung-Ju;Lee, Young-Ok
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.61-63
    • /
    • 2011
  • Implantable cardioverter defibrillator (ICD) can be a crucial therapeutic modality for pediatric patients with congenital heart disease, Brugada syndrome, long QT syndrome and cardiomyopathy. Because transvenous implantation of ICD is mostly unfeasible for pediatric patients due to anatomical and technical limitations, epicardial patch type or subcutaneous type ICD have been used. Implantation of these alternative ICDs, however, was reported to be frequently associated with significant complications. We report a case of successful intrapericardial implantation of a single coil-type ICD through the transverse sinus in a 27 month-old child weighing lesser than 10 kg, and it was inferred from this experience that this alternative technique may decrease complications and morbidities after ICD implantation in children.

Mortality Analysis of Implantable Cardioverter Defibrillator (ICD) (체내제세동기 이식 시의 사망률분석)

  • Park, Kwang-Il
    • The Journal of the Korean life insurance medical association
    • /
    • v.30 no.2
    • /
    • pp.12-15
    • /
    • 2011
  • Background: The beneficial effects of implantable cardioverter defibrillators (ICDs) in primary and secondary prevention patients are well established. However, data on potential differences between both groups in mortality are scarce. The aim of this study was to assess extra risk differences between primary and secondary prevention ICD recipients. Methods: Comparative mortality figures were calculated from a source article using mortality analysis methods. Results: Mortality ratio (MR) of primary and secondary prevention ICD recipients were 393% and 373%. Excess death rates (EDR) of both groups were 42 and 38 per 1,000. Discussion: MR and EDR were higher in primary prevention group. But, there was no significant difference.

  • PDF

A Study on the Ways to Improve Uiwang ICD Facilities and Operation (의왕ICD 시설 및 운영개선 방안에 대한 연구)

  • Kim, Hyun-Ju;Kang, Sin-Seok;Park, Byeong-In
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3268-3277
    • /
    • 2011
  • Uiwang ICD, which is the only inland container depot in the capital area, is equipped with modern facilities, and loading and unloading equipment, and can handle 1,000,000 TEU annually.It has many advantages such as advantageous conditions of location, the role of foothold for distribution transportation in the capital area, so it plays an important role of vitalizing the railroad transport. However, Uiwang ICD has reached the limit in the vitalization of railroad transport of containerized cargo due to the current problems in facilities and operations. This research analyzed the Uiwang ICD's problems by dividing them into facilities problems and operational problems, and presented short-term and medium and long-term improvement measures with the year 2023 when the private use permission expires as the basic year. However, the vitalization of railroad transport of Uiwang ICD can be attained only when it has support and cooperation from the government, Uiwang-si, Korea Rail Network Authority, and other related organizations together with efforts of Korea Railroad Corporation, and occupant companies. Such improvement measures for Uiwang ICD are expected to contribute to establishing combined transport system and forming efficient railroad distribution infrastructures and vitalizing railroad distribution, and also contribute to the government's low-carbon green growth policy by building environment-friendly transport system.

  • PDF

The signal processing algorithm of the Missile Flight Test Launch Control System (비행시험 발사통제 시스템의 신호처리 알고리즘)

  • Oh, Jino
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1965-1972
    • /
    • 2015
  • The Missile Flight Test Launch Control System is to operate in conjunction with the Fire Control System during flight test to guided weapons. Also, this is a system for the test control and situation monitoring depending on the type of guided weapons and testing purposes. Message structure, communication protocols, such as data types for interworking with the fire control system and the Missile Flight Test Launch Control System are defined in the Launch Control ICD(Interface Control Document). ICD are composed differently of each guided weapons system and each test object. Previously, in order to interwork with the Fire Control System, the interlocking software was developed, which had a variety of problems. Therefore, we developed a new parsing algorithm in order to recognize the variety of Launch Control ICD and verified that the algorithm operates normally by checking transmitting and receiving various message in conjunction with the fire control system.

Design of Automatic Model Verification for System Integration Laboratory (통합시험환경 모델 검증 자동화 설계)

  • Yang, Seung-Gu;Cho, Yeon-Je;Jo, Kyoung-Yong;Ryu, Chang-Myung
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.361-366
    • /
    • 2019
  • In developing the avionics system, a system integration laboratory (SIL) is established to verify the function and interworking of individual components. In case of individual verification of SIL's components and system integration, a SIL model that simulates the function and interworking of each equipment is developed and used. A SIL model shall be pre-verified against all data defined in the interface control document (ICD) before interworking with the actual equipment and reverified even when the ICD changes or functions change. However, if the verification of the SIL model is performed manually, the verification of the individual SIL model takes considerable time. For this reason, selective regression tests are often performed to determine a impact of SIL models on ICD changes and some functional changes. In this paper, we designed SIL model verification automation method to perform regession test by reducing verification time of SIL model and verify the usefulness of verification automation design by developing SIL model verification automation tool.

Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

  • Jin, Bo Kyung;Bang, Ji Seok;Choi, Eun Young;Kim, Gi Beom;Kwon, Bo Sang;Bae, Eun Jung;Noh, Chung Il;Choi, Jung Yun;Kim, Woong Han
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.125-129
    • /
    • 2013
  • Purpose: The use of implantable cardioverter defibrillators (ICDs) to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was $14.5{\pm}5.4$ years (range, 2 to 22 years). The follow-up duration was $28.9{\pm}20.4$ months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1), cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years). Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia. During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

Effects of Radio Frequency Electromagnetic Fields Emitted by WCDMA Mobile Phones on Pacemakers and ICDs (WCDMA 휴대전화 전자파가 인공심장 박동기 및 이식형 제세동기에 미치는 영향)

  • Chung, Jai Won;Choi, Soo Beom;Park, Jee Soo;Kim, Deok Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.148-154
    • /
    • 2015
  • Reports show that global system for mobile communication (GSM) mobile phones, or two-generation (2G) mobile phones, could affect functions of pacemakers and implantable cardioverter defibrillators (ICDs). In this study, we evaluated the effects of radio frequency electromagnetic fields (RF-EMFs) emitted by wideband code division multiple access (WCDMA) mobile phones, which were third-generation (3G) mobile phones, on pacemakers and ICDs. Five pacemakers and three ICDs were subjected to in-vitro test using a ECG simulator. We used a WCDMA module (average power : 0.25 W, frequency band : 1950 MHz) instead of a real WCDMA mobile phone. To assess the effects of the WCDMA module on pacemakers and ICDs, each implantable device was placed in close proximity (within 3 mm) to the WCDMA module for 5 min. As a result, no effects were observed on the five pacemakers and three ICDs for the RF-EMFs emitted by the WCDMA module. Because WCDMA mobile phones have the higher frequency band (1800-2200 MHz) and lower power output (0.01-0.25 W) than GSM moboile phone, the RF-EMFs emitted by WCDMA mobile phones do not affect patients with pacemaker or ICD.

Disagreement of ICD-10 Codes Between a Local Hospital Information System and a Cancer Registry

  • Sriplung, Hutcha;Kantipundee, Tirada;Tassanapitak, Cheamjit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.259-263
    • /
    • 2015
  • Background: In the field of cancer, the ICD-10 coding convention is based on the site of a neoplasm in the body and usually ignores the morphology, thus the same code may be assigned to tumors of different morphologic types in an organ. Nowadays, all general (provincial) and center hospitals in Thailand are equipped with the hospital information system (HIS) database. Objective: This study aimed to find the characteristics and magnitude of agreement represented by the positive predictive value (PPV) of provisional cancer diagnoses in the HIS database in Pattani Hospital in Thailand in comparison with the final cancer diagnosis of the ICD-10 codes generated from a well established cancer registry in Songklanagarind Hospital, the medical school hospital of Prince of Songkla University. Materials and Methods: Data on cancer patients residing in Pattani province who visited Pattani Hospital from January 2007 to May 2011 were obtained from the HIS database. The ICD-10 codes of the HIS computer database of Pattani Hospital were compared against the ICD-10 codes of the same person recorded in the hospital-based cancer registry of Songklanagarind Hospital. The degree of agreement or positive predictive value (PPV) was calculated for each sex and for both sexes combined. Results: A total of 313 cases (15.9%) could be matched in the two databases. Some 222 cases, 109 males and 113 females, fulfilled the criteria of referral from Pattani to Songklanagarind Hospitals. Of 109 male cancer cases, 76 had the same ICD-10 codes in both hospitals, thus, the PPV was 69.7% (95%CI: 60.2-78.2%). Agreement in 76 out of 113 females gave a PPV of 67.3% (95%CI: 57.8-75.8%). The two percentages were found non-significant with Fisher's exact p-value of 0.773. The PPV for combined cases of both sexes was 68.5% (95%CI: 61.9-74.5%). Conclusions: Changes in final diagnosis in the referral system are common, thus the summary statistics of a hospital without full investigation facilities must be used with care, as the statistics are biased towards simple diseases able to be investigated by available facilities. A systematic feedback of patient information from a tertiary to a referring hospital should be considered to increase the accuracy of statistics and to improve the comprehensive care of cancer patients.