• 제목/요약/키워드: ICCs

검색결과 98건 처리시간 0.024초

Comparison of Femoral Anteversion Angle and Determination of Reliability Measured at Three Different Anatomical References of the Tibial Crest During the Trochanteric Prominence Angle Test

  • Lee, Ji-Hyun;Yoon, Tae-Lim;Choi, Sil-Ah;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.55-60
    • /
    • 2012
  • The trochanteric prominence angle test (TPAT) has been used to measure the femoral anteversion angle between the tibial crest and the vertical line. However, the exact anatomical reference of the tibial crest has not yet been identified in the literature. Thus, the purposes of this research were twofold: first, to compare the femoral anteversion angle measured at three different anatomical references of the tibial crest (the proximal tibial crest, the proximal third of tibial crest, and the proximal half of tibial crest) and, second, to determine inter-and intra-rater reliabilities of the femoral anteversion angle measured at these three different anatomical references of the tibial crest during the TPAT. We recruited 14 healthy subjects, and a total of 28 legs were examined. The TPAT was measured using a digital inclinometer. A 1-way repeated-measure analysis of variance was used to compare the femoral anteversion angle measured at three different anatomical references of the tibial crest, and intraclass correlation coefficients (ICCs) were calculated to determine reliability. The femoral anteversion angle measured at the proximal tibial crest was significantly higher than that at the proximal third of the tibial crest and the proximal half of the tibial crest. The inter-and intra-rater reliabilities of femoral anteversion angle were measured at three anatomic references of the tibial crest were all found to be high during the TPAT (ICC=.9 0~.98). In conclusion, clinicians should recognize that the different degrees of the femoral anteversion angle could be measured when different anatomical references of the tibial crest were used, and that reliabilities were high when an exact anatomical reference of the tibial crest was used during the TPAT.

Comparison of the reproducibility of panoramic radiographs between dentulous and edentulous patients

  • Park, Jong-Woong;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.95-102
    • /
    • 2014
  • Purpose: This study was performed to evaluate the reproducibility of panoramic radiographs of dentulous and edentulous patients. Materials and Methods: The reproducibility of panoramic radiographs was evaluated using the panoramic radiographs acquired from 30 anterior dentulous patients by using a common biting positioning device (dentulous group) and 30 anterior edentulous patients by using chin-support devices to take a panoramic radiograph (edentulous group), respectively; these patients had undergone 3 or more panoramic radiographs. The widths and angles between the designated landmarks were measured on the panoramic radiographs, and the reproducibility was evaluated using the intraclass correlation coefficient (ICC) and the coefficient of variation. Results: In the dentulous and edentulous groups, the ICCs of the mandibular ramus and mandibular angle areas were higher than the condylar head and zygomatic areas. The mandibular ramus and angle areas showed statistically lower mean coefficients of variation than the condylar head and zygomatic areas in the dentulous group. The mandibular angle area showed a significantly lower mean coefficient of variation than the zygomatic area in the edentulous group. By comparing the two groups, each ICC of the edentulous group was lower than that of the dentulous group, and the mean coefficients of variation of the mandibular ramus area, zygomatic area, left condylar inclination, and ramus ratio between the right and the left in the edentulous group were significantly higher than those in the dentulous group. Conclusion: Biting positioning for dentulous patients provided better positioning reproducibility than chin-support positioning when performing panoramic radiography for edentulous patients.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권4호
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Reliability of Scapular Downward Rotation Measurement in Subjects With Scapular Downward Rotation Syndrome

  • Choi, Woo-Jeong;Lee, Ji-Hyun;Jeong, Hyo-Jung;Yoon, Tae-Lim;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제21권3호
    • /
    • pp.73-79
    • /
    • 2014
  • The purposes of the current study were to (1) estimate the inter-rater agreement for visual assessment of scapular downward rotation (SDR), (2) develop the scapular downward rotation index (SDRI) as a method to measure SDR objectively and quantitatively, and (3) analyze the intra- and inter-rater reliability of the SDRI. Twenty subjects with scapular downward rotation syndrome (SDRS) were recruited for this study. The visual assessment and the measurement for the SDRI were conducted by two examiners in two sessions each. The SDRI [$(a-b){\div}a{\times}100$] is calculated with the measurement of two linear distances: One is a perpendicular distance from the root of the scapular spine to the thoracic mid-line (a), and the other is a perpendicular distance from the inferior angle of the scapula to the thoracic mid-line (b). Cohen's kappa coefficient was calculated to estimate the inter-rater agreement for visual assessment. Intra-class correlation coefficients (ICCs) with a 95% confidence interval (CI), the standard error of measurement, and minimal detectable differences were calculated to assess intra- and inter-rater reliability of SDR measurement using the SDRI. The results indicated that the kappa coefficient of inter-rater agreement for visual assessment was fair (${\kappa}=.21$). The intra-rater reliability of SDR measurement using the SDRI was excellent for examiner 1 (ICC=.92, 95% CI=.78~.97) and good for examiner 2 (ICC=.82, 95% CI=.55~.93). The inter-rater reliability was moderate (ICC=.73, 95% CI=.32~.89). These findings showed that SDR measurement using the SDRI for subjects with SDRS may be considered reliable and better than the visual assessment.

휴대용 디지털 압통기의 측정자내 신뢰도 및 측정자간 신뢰도 측정 (Measurement of Intrarater Reliability and Interrater Reliability of a Portable Digital Pressure Algometer)

  • 이원휘;오재섭;박규남;권오윤;송미혜;박호동;이경중
    • 한국전문물리치료학회지
    • /
    • 제15권3호
    • /
    • pp.62-69
    • /
    • 2008
  • The purpose of this study was to measure intrarater and interrater reliability of a portable digital pressure algometer. Fifty healthy subjects were recruited for this study. Pressure pain thresholds of splenius capitis, levator scapular, and upper trapezius muscles were measured using by FPK algometer and portable digital pressure algometer. Three trials were done on each subject by two examiners. Intraclass correlation coefficients (ICCs) were used to determine the reliability of each measure. The intrarater reliability of the FPK algometer was good and excellent (ICC .63~.79) and the interrater reliability was poor and good (ICC .15~.57). The intrarater reliability of a portable digital pressure algometer was excellent (ICC .75~.86) and the interrater reliability was poor and good (ICC .35~.61). This result suggests that the intrarater reliability and interrater reliability of a portable digital pressure algometer were better than an FPK algometer.

  • PDF

한글판 아동 균형척도(Pediatric Balance Scale)의 측정자간 신뢰도 (Inter-Examiner Reliability of the Korean Version of the Pediatric Balance Scale)

  • 고명숙;이남현;이정아;전혜선
    • 한국전문물리치료학회지
    • /
    • 제15권1호
    • /
    • pp.86-95
    • /
    • 2008
  • The Pediatric Balance Scale (PBS) is a modified Berg's Balance Scale developed as a balance measure for school-aged children with mild to moderate motor impairments. The purpose of this study was to determine the inter-examiner reliability of the Korean version of PBS when applied to children with developmental delays. In this study, PBS was administrated to a total of 79 children with developmental delays (17 with global developmental delay, 31 with cerebral palsy, and 31 with mental retardation) in the Seoul Community Rehabilitation Center. Two pediatric trained physical therapists with longer than 13 year of clinical experience scored the children's performance blind, while replaying videotaped data. The inter-examiner reliability was statistically determined by intraclass correlation coefficients (ICCs). The results of this study revealed that the Korean version of PBS seems to have high inter-examiner reliability when applied to children with movement disorders such as global developmental delay (ICC=.96) and cerebral palsy (ICC=.97); however, it has relatively lower inter-examiner reliability (ICC=.78) for children with developmental delay secondary to mental retardation. therefore, the results support that the Korean version of the PBS could be a useful clinical measurement to assess the balance skills for children with developmental delay who have an adequate level of cognition to enable them to fol1ow the verbal instructions to complete the test.

  • PDF

크레인 제어를 위한 통합 네트워크 및 제어 시스템 (Integrated Communication and Control System for Cranes)

  • 김응석;김문철;허우정;신경봉;박정민;유범재;조영조;김광배;류해영;안병규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1257-1259
    • /
    • 1996
  • In this paper, we introduce an integrated communication and control system(ICCS) for control of a crane. The system is integrated with a compasite technique as a network interfacing, a user interfacing and a system control for continuous process like as a container crane. The field-bus(Profibus) network module is used to interconnect each input/output module with main control unit. The MMI system for user interfacing is integrated with an ODBC-based data management tool and IECl131-based control logic design tool(Soft-Logic Designer:SLD). The each programmed control task in the main Controller is executed using a petri-net based scheduler.

  • PDF

노인들에 대한 균형검사의 검사-재검사 신뢰도 (Test-retest Reliability of Balance Tests in Older Adults)

  • 강순희
    • 대한물리치료과학회지
    • /
    • 제16권4호
    • /
    • pp.49-57
    • /
    • 2009
  • Background: The purpose of this study was to assess the test-retest reliability of balance measurements in older adults using balance measurement system(Good Balance). Methods: The subjects consisted of 49 female and 20 male in community-dwelling older adults. This study used a repeated-measure design. Each subject completed all the different tests once and they were then repeated with 2 minutes in between. Repeated two-ways analysis of variance(ANOVA), representing two test times and both sexes, was calculated for each of the two dependent variables. Intraclass correlation coefficients(ICCs) were used to assess the test-retest reliability. Results: 1) There was not significant difference between test and retest for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There was not significant difference between males and females for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There were not the interaction effects between genders and test time under three conditions. 2) The reproducibility between test and retest was excellent for anterioposterior sway speed(ICC=.77) under condition of normal standing with eyes open, and for mediolateral sway speed(ICC=.76) and anterioposterior sway speed(ICC=.84) under condition of semitandem standing with eyes open. The reproducibility between test and retest was fair to good for mediolateral sway speed(ICC=.64) under condition of normal standing with eyes open, for mediolateral sway speed(ICC=.63) and anterioposterior sway speed(ICC=.75) under condition of normal standing with eyes closed. Conclusion: Balance tests in older adults using balance measurement system(Good Balance) demonstrated acceptable levels of reliability.

  • PDF

Measurement of Thoracic Limb Joint Reference Angles in Purebred Shih-Tzu Dogs by Computed Tomography

  • Jeong, Jaemin;Kim, Eunki;Jeong, Youngeun;Jeong, Seong Mok;Lee, Hae Beom;Kwon, Youngsam
    • 한국임상수의학회지
    • /
    • 제37권4호
    • /
    • pp.169-174
    • /
    • 2020
  • The purpose of this study was to establish normal values for the thoracic limb joint reference angles in Shih Tzu dogs and to describe the standardized CT methodology for measuring the joint reference angle of the humerus. Five pairs of thoracic limbs of Shih Tzu dogs were collected for the CT scans in this study. Three blinded observers measured the joint reference angle of the humerus and radius for each dog by using CT scans in the frontal, sagittal, and axial planes. The means (± SDs) for the average of the right and left humeral joint reference angles were as follows: mMPHA, 83.74 ± 3.95°; mLDHA, 85.04 ± 2.57°; mCaPHA, 46.75 ± 2.20°; mCrDHA, 79.47 ± 1.97°; and HTA, 19.16 ± 2.38°. Means (± SD) for the average of right and left of the radial joint reference angles were as follows: aMPRA, 85.04 ± 1.58°; aLDRA, 87.59 ± 1.37°; aCrPRA, 84.60 ± 1.46°; aCdDRA, 84.27 ± 1.79°; and RTA, 20.91 ± 3.00°. The intraclass correlation coefficients (ICCs) of the joint reference angles for the inter- and intraobserver reliability were good to excellent, except those for the mCrHA and HTA were moderate. Our results suggest that the method of measuring joint reference angles of other long bones by using CT can be applied to thoracic limbs and can extract valid values for one specific breed.

Validity of the Wii Balance Board for Evaluation of Medial Patellar Luxation in Small Sized Dog

  • Lee, Shinho;Lee, Joo-Myoung;Park, Hyunjung;Cha, Yuri;Cheong, Jongtae
    • 한국임상수의학회지
    • /
    • 제36권6호
    • /
    • pp.297-300
    • /
    • 2019
  • Wii® balance board (WBB) is a device that can measure and record body sway. This study was conducted to evaluate the reliability of WBB in small sized dog as inexpensive, portable and convenient tool. The center of pressure path length (CPPL) and 95% confidence ellipse area (Area 95) were evaluated with only two plates of WBB. The parameters were evaluated between no load (0 kg) and mass group (0.25-4 kg on each one plate). 23 dogs (2.3-7.3 kg) were evaluated for with hindlimb standing for 10 seconds. The mass group showed a significant value in comparison to the no load during the measurement. And intra-class correlation coefficients (ICCs) between CPPL and Area 95 revealed very high both mass and dog group. In the evaluation of medial patellar luxation (MPL) as a diagnostic tool, 80 dogs with MPL and 23 non-affected dogs were used. In studies of CPPL and Area 95, significant differences were found between non-affected and MPL groups for 10 and 30 seconds, respectively. The WBB can be used as a valid tool for evaluating hind limb standing balance and can be useful as an objective tool to present clinical results in small sized dog with MPL.