• Title/Summary/Keyword: ICC

Search Result 658, Processing Time 0.039 seconds

An Analysis of the Reliability and Validity of a Korean Version of the Mobility and Gait Assessment Tools for Patients with Stroke

  • Jang, Ho Young;Lee, Jeong-Hoon;Oh, Jung Lim;Lee, Hyun Soo;Lee, Suk Min
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 2018
  • Purpose: This study aimed to systematically analyze the reliability and validity of Korean versions of mobility and gait assessment tools for patients with stroke. Methods: Two reviewers conducted an independent literature search and systematically reviewed the literature. Literature published until June of 2017 was searched using search engines for electronic databases. The 2 reviewers reviewed the title and abstract of each article. Among the articles examined, we read the full text of those judged to be suitable for our study. We classified the selected data into research methods and results. The determination was made through mutual agreement. Results: The reviewers selected 5 articles related to the purpose of this study. The DGI was found to be moderately associated with BBS, 10MWT, and TUG in intra-rater reliability (ICC=0.92), inter-rater reliability (ICC=0.88), and concurrent validity tests. The FGA demonstrated a high level of reliability with intra-rater (ICC=0.92-0.95) and inter-rater reliability (ICC=0.91, 0.95). The intra-rater reliability of the RMI was high at ICC=0.98. Its concurrent validity showed a high association with STREAM and BI. The intra-rater reliability of the MAS was ICC=0.75-0.99. Its inter-rater reliability was very high, exceeding 0.99. The inter-rater reliability of the Tinetti-gait Scale was ICC=0.91, and its concurrent validity was moderately associated with the DGI, 10WMT, OLST, FM-L/E, and STS. Conclusion: The results of this study revealed that the reliability and validity of the Korean versions of the mobility and gait assessment tools were high.

Reliability and Validity of the Balancia using Wii Balance Board for Assessment of Balance with Stroke Patients (뇌졸중 환자들의 균형평가를 위한 Balancia 프로그램의 신뢰도와 타당도)

  • Park, Dae-Sung;Lee, Dong-Yeop;Choi, Sung-Jin;Shin, Won-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2767-2772
    • /
    • 2013
  • Balance is the foundation for all active daily livings. Evaluation of balance has been conducted to measure postural sway of center of pressure(COP). The purpose of this study is to introduce the Balancia and to examine the validity and inter-, intra-reliability for measure of balance with stroke patients. COP was measured by Wii balance board. The subjects Participated in this study were 39 stroke patients. Intra- and inter-reliability was examined using intraclass correlation coefficient(ICC) with 95% confidence interval. In the result of intra- and inter-reliability, all COP parameters of postural sway showed high to very high reliability with ICC=.793-.939 and ICC=.791-.955. Validity was determined by correlation with Accusway force plate. There were high validity with ICC=.851-.955 between tools. According to these results, the Balancia showed high validity and reliability. It is a useful clinical tool for evaluating balance in stroke patients.

Effects of Carthami flos on pacemaker potentials of small intestinal and colonic interstitial Cells of Cajal (홍화의 생쥐 소장 및 대장 카할 간질세포의 향도잡이 전위 조절에 미치는 효능에 관한 연구)

  • Kim, Byung Joo
    • Herbal Formula Science
    • /
    • v.27 no.4
    • /
    • pp.237-244
    • /
    • 2019
  • Objectives : The purpose of this study was to investigate the effects of Carthami flos on pacemaker potentials of small intestinal and colonic Interstitial Cells of Cajal (ICC). Methods : To dissociate the ICC, we used enzymatic digestions from the small intestine and colon in mice. In the ICC, the electrophysiological whole-cell patch-clamp configuration was used to record pacemaker potentials in the cultured ICC. Results : 1. The ICC generated pacemaker potentials in the murine small intestine and colon. 2. Pretreatment with a Ca2+ free solution and thapsigargin, a Ca2+-ATPase inhibitor in the endoplasmic reticulum, stopped the pacemaker potentials. In the case of Ca2+-free solutions, Carthami flos did not induce membrane depolarizations in the murine small intestine and colon. However, when thapsigargin in a bath solution was applied, Carthami flos induced membrane depolarizations only in the murine colon. 3. Pretreatment with 2-APB (transient receptor potential melastatin (TRPM) channel inhibitor) abolished the pacemaker potentials and suppressed Carthami flos-induced effects in the murine small intestine and colon. 4. However, pretreatment with T16Ainh-AO1 (Ca2+ activated Cl- channel; anoctamin 1 (ANO1) inhibitor) did not affect the pacemaker potentials and induced Carthami flos-induced effects only in the murine small intestine. Conclusions : These results suggest that Carthami flos can modulate the pacemaker activity of ICC and the mechanisms underlying pacemaking in ICC might be different in the small intestine and the colon.

Efficient Multicasting Mechanism for Mobile Computing Environment (물류트랙킹 장비에 활용되는 WCDMA/GSM 이중 대역 안테나 설계 및 성능 검증)

  • Lee, Eun-Kyu;Choi, Sung-Pill;Moon, Young-Sik;Jeon, Mi-Jin;Jo, Jae-Hui;Kim, Jae-Joong;Choi, Hyung-Rim
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.896-897
    • /
    • 2013
  • In recent years, logistics tracking Device using GSM & WCDMA to improve logistics efficiency are being extensively researched. The purpose of this paper is to examine the performance development antenna usable cargo container security transport. Antenna developed by study were optimized to match logistics environment apply to GSM & WCDMA dual frequency for monitering system. The measure of antenna have confirmation VSWR is 3:1 measured in return loss -10dB. Reliability of this antenna has been verified about GSM & WCDMA through test-operation between the south korea and Russia.

  • PDF

The reliability test of a smart insole for gait analysis in stroke patients

  • Seo, Tae-Won;Lee, Jun-Young;Lee, Byoung-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.30-40
    • /
    • 2022
  • Background: This study analyzed the reliability of smart guides for gait analysis in patients with stroke. Design: Cross-sectional study. Methods: The participants of the study were 30 patients with stroke who could walk more than 10 m and had an MMSE-K test score of ≥24. Prior to the experiment, the subjects or their guardians entered their demographic characteristics including gender, age, height, weight into the prepared computer. The experiment was conducted in a quiet, comfortable, and independent location, and the patient was reminded of the equipment description, precautions, and safety rules for walking. A smart insole was inserted into the shoes of the patients and the shoes were put on before the patients walked three times on the 5-m gait analysis system mat installed in the laboratory. Results: The reliability of the equipment was compared with that of the gait analysis system, and the results of this study are as follows: among the gait analysis items, velocity had an ICC=0.982, the cadence had an ICC=0.905, the swing phase on the side of the gait cycle had an ICC=0.893, the swing phase on the side of the gait had an ICC=0.839, that on the non-affected side had an ICC=0.939, single support on the affected side had an ICC=0.812, and support on the non-affected side had an ICC=0.767. Conclusion: The results of this study indicate no statistical difference between the smart insole and the gait analysis system. Therefore, it is believed that real-time gait analysis through smart insole measurement could help patients in rehabilitation.

Long-term consistency of clinical sensory testing measures for pain assessment

  • Pablo Bellosta-Lopez;Victor Domenech-Garcia;Thorvaldur Skuli Palsson;Pablo Herrero;Steffan Wittrup Mcphee Christensen
    • The Korean Journal of Pain
    • /
    • v.36 no.2
    • /
    • pp.173-183
    • /
    • 2023
  • Background: Understanding the stability of quantitative sensory tests (QSTs) over time is important to aid clinicians in selecting a battery of tests for assessing and monitoring patients. This study evaluated the short- and long-term reliability of selected QSTs. Methods: Twenty healthy women participated in three experimental sessions: Baseline, 2 weeks, and 6 months. Measurements included pressure pain thresholds (PPT) in the neck, upper back, and leg; Pressure-cuff pain tolerance around the upper-arm; conditioned pain modulation during a pressure-cuff stimulus; and referred pain following a suprathreshold pressure stimulation. Intraclass correlation coefficients (ICC) and minimum detectable change (MDC) were calculated. Results: Reliability for PPT was excellent for all sites at 2 weeks (ICC, 0.96-0.99; MDC, 22-55 kPa) and from good to excellent at 6 months (ICC, 0.88-0.95; MDC, 47-91 kPa). ICC for pressure-cuff pain tolerance indicated excellent reliability at both times (0.91-0.97). For conditioned pain modulation, reliability was moderate for all sites at 2 weeks (ICC, 0.57-0.74; MDC, 24%-35%), while it was moderate at the neck (ICC, 0.54; MDC, 27%) and poor at the upper back and leg at 6 months. ICC for referred pain areas was excellent at 2 weeks (0.90) and good at 6 months (0.86). Conclusions: PPT, pressure pain tolerance, and pressure-induced referred pain should be considered reliable procedures to assess the pain-sensory profile over time. In contrast, conditioned pain modulation was shown to be unstable. Future studies prospectively analyzing the pain-sensory profile will be able to better calculate appropriate sample sizes.

Independent Cooling Controller for Temperature Control of High Strength and Atmosphere Corrosion Resisting Steel in Hot Strip Mills (고강도 내후성강의 온도제어를 위한 ICC 제어기 개발)

  • Park, Cheol Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.327-335
    • /
    • 2015
  • In this paper, we propose an independent cooling control (ICC) scheme for high strength and atmosphere corrosion resisting steel to obtain the desired temperature and properties along the longitudinal direction of the steel in the run-out table (ROT) process. A temperature model of the independent process is developed to divide the ROT into front and back sections. The control concept uses field data, problem analysis, and a time-temperature transformation diagram. The effectiveness of the proposed control is verified using simulation results under a temperature disturbance by the transformation in the middle of the ROT. The results of a hot strip mill field test show that the temperature control performance is significantly improved by the proposed control scheme.

A Comparative Study on the exclusions in 1982 and 2009 Institute Cargo Clauses (2009년 ICC와 1982년 ICC상의 면책위험 비교 연구)

  • Lee, Shie-Hwan
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.43
    • /
    • pp.275-295
    • /
    • 2009
  • After a long period of development and worldwide consultation, the London-based Joint Cargo Committee has revised the Institute Cargo Clauses (A), (B) & (C) and some ancillary Institute Clauses. The revision mainly include a clarification of the exclusions within the clauses, some modernization of the language of the clauses and new definitions of some terms. With these revisions, the coverage is widened to offer more protection to the assured. This may enable the widely used Institute Cargo Clauses to receive even greater worldwide acceptance. The following are the main changes in the new 2009 ICC compared with the 1982 ICC. 1. Insufficient or unsuitable Packing or Preparation(Clause 4.3): The revised clause is more favourable to the assured because under the revised clause this sub-clause is only applicable to (a) where packing or preparation is carried out by the assured or their employees or (b) packing or preparation takes place before the attachment of the risk. 2. Insolvency or Financial Default (Clause 4.6): The insolvency and financial default wording is incorporated in the revised clauses, making it more favourable to the assured. 3. Unseaworthiness (Clause 5): The revision is more favourable to the assured in that it limits the exclusion in relation to the unfitness of vehicles, vessels or containers to cases where the assured or their employees are privy to such unfitness. 4. Terrorism (Clause 7): A new definition of "terrorism" is introduced and the revised clause also widens the acts of an individual to encompass ideological and religious motives.

  • PDF

The Revision of Transit Clause in the Institute Cargo Clauses (협회적하약관(ICC)상 운송조항(Transit Clause)의 변천과정에 관한 연구)

  • Lee, Jay-Bok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.43
    • /
    • pp.337-370
    • /
    • 2009
  • The Joint Cargo Committee of International Underwriting Association of London (IUA) and Lloyd’s Market Association (LMA) have issued the revised version of Institute Cargo Clauses A, B, C, Institute Cargo Clauses (Air) and their accompanying War and Strikes Clauses. The Institute Cargo Clauses ("ICC") were last revised in 1982. Following a two year long consultation process, the latest edition of the ICC clauses became available to the Market on 1st January 2009. The overall result of the amendments to the 1982 ICC has been to create clearer policies that are more favourable to the Assured. Exclusions have also been amended to the advantage of the assured. The Transit Clause has seen a large revision, again more favourable to the Assured. The insurance now attaches within the warehouse or place of storage when the goods are "first moved$\cdots$ for the purpose of the immediate loading into or onto the carrying vehicle or other conveyance for the commencement of transit" whereas previously the insurance would not attach until the goods left the warehouse. Furthermore, the insurance now terminates on completion of unloading from the vessel at (rather than delivery to) the final warehouse or at a warehouse prior to the destination named in the contract of insurance which the Assured or their employees elect to use either for storage or distribution.

  • PDF

Reliability of Visual Gait Analysis according to Clinical Experience Level of Physical Therapists (임상 물리치료사의 경험에 따른 시각적 보행 분석의 신뢰도 연구)

  • Lee, In-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.174-179
    • /
    • 2013
  • Purpose: Visual gait analysis plays a pivotal role in determining the important gait problem of patients. A few studies have been published and have received little attention regarding visual gait analysis on patients with orthopedic problems. The purposes of this study were to investigate the difference of reliability levels according to experience of clinical physical therapists. Methods: Thirty-five clinical physical therapists, 5 high experienced, 15 experienced, and 15 inexperienced, were recruited and individually evaluated these videotaped gait patterns of the participants, and filled up the structured gait analysis form. The gait of nine participants was videotaped. Reliability levels were calculated by the Intraclass Correlation Coefficients (ICC). Results: The inter-rater reliability of high experienced group (ICC=0.56; 95% CI: 0.50-0.62) was comparable to that of the experienced raters (ICC=0.48; 95% CI: 0.43-0.53) and inexperienced group (ICC=0.42; 95% CI: 0.38-0.46). High experienced group reached a higher inter-rater reliability level. The average intra-rater reliability of the high experienced group was 0.70 (ICCs ranging from 0.54 to 0.82). The experienced group reached an average intra-rater reliability of 0.61 (ICCs ranging from 0.47 to 0.81). The inexperienced group attained average ICC values of 0.53 (ICCs ranging from 0.30 to 0.74). Conclusion: Use of a structured gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis.