• Title/Summary/Keyword: ICA filter

Search Result 24, Processing Time 0.024 seconds

Design of Filter to Remove Motionartifacts of Photoplethysmography Based on Indepenent Components Analysis and Filter Banks (독립성분 분석법과 필터뱅크를 기반한 PPG 신호의 동잡음제거 필터 설계)

  • Lee, Ju-won;Lee, Byeong-ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1431-1437
    • /
    • 2016
  • In mobile healthcare device, when to measure the heart rate by using the PPG signal, its performance is reduced according to the motion artifacts that is the movement of user. This is because the frequency range of motion (0.01-10 Hz) and that of PPG signals overlap. Also, the motion artifacts cannot be rectified by general filters. To solve the problem, this paper proposes a method using filter banks and independent component analysis (ICA). To evaluate the performance of the proposed method, we were artificially applied various movements and compared heart rate errors of the moving average filter and ICA. In the experimental results, heart rate error of the proposed method showed very low than moving average filter and ICA. In this way, it is possible to measure stable heart rate if the proposed method is applied to the healthcare terminal design.

A CLASSIFICATION FOR PANCHROMATIC IMAGERY BASED ON INDEPENDENT COMPONENT ANALYSIS

  • Lee, Ho-Young;Park, Jun-Oh;Lee, Kwae-Hi
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.485-487
    • /
    • 2003
  • Independent Component Analysis (ICA) is used to generate ICA filter for computing feature vector for image window. Filters that have high discrimination power are selected to classify image from these ICA filters. Proposed classification algorithm is based on probability distribution of feature vector.

  • PDF

Face Recognition Using A New Methodology For Independent Component Analysis (새로운 독립 요소 해석 방법론에 의한 얼굴 인식)

  • 류재흥;고재흥
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.305-309
    • /
    • 2000
  • In this paper, we presents a new methodology for face recognition after analysing conventional ICA(Independent Component Analysis) based approach. In the literature we found that ICA based methods have followed the same procedure without any exception, first PCA(Principal Component Analysis) has been used for feature extraction, next ICA learning method has been applied for feature enhancement in the reduced dimension. However, it is contradiction that features are extracted using higher order moments depend on variance, the second order statistics. It is not considered that a necessary component can be located in the discarded feature space. In the new methodology, features are extracted using the magnitude of kurtosis(4-th order central moment or cumulant). This corresponds to the PCA based feature extraction using eigenvalue(2nd order central moment or variance). The synergy effect of PCA and ICA can be achieved if PCA is used for noise reduction filter. ICA methodology is analysed using SVD(Singular Value Decomposition). PCA does whitening and noise reduction. ICA performs the feature extraction. Simulation results show the effectiveness of the methodology compared to the conventional ICA approach.

  • PDF

Face Recognition By Combining PCA and ICA (주 요소와 독립 요소 분석의 통합에 의한 얼굴 인식)

  • Yoo Jae-Hung;Kim Kang-Chul;Lim Chang-Gyoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.4
    • /
    • pp.687-692
    • /
    • 2006
  • In a conventional ICA(Independent Component Analysis) based face recognition method, PCA(Principal Component Analysis) first is used for feature extraction, ICA learning method then is applied for feature enhancement in the reduced dimension. It is not considered that a necessary component can be located in the discarded feature space. In the new ICA(NICA), learning extracts features using the magnitude of kurtosis (4-th order central moment or cumulant). But, the pure ICA method can not discard noise effectively. The synergy effect of PCA and ICA can be achieved if PCA is used for noise reduction filter. Namely, PCA does whitening and noise filtering. ICA performs feature extraction. Experiment results show the effectiveness of the new ICA method compared to the conventional ICA approach.

Improved Feature Extraction of Hand Movement EEG Signals based on Independent Component Analysis and Spatial Filter

  • Nguyen, Thanh Ha;Park, Seung-Min;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.515-520
    • /
    • 2012
  • In brain computer interface (BCI) system, the most important part is classification of human thoughts in order to translate into commands. The more accuracy result in classification the system gets, the more effective BCI system is. To increase the quality of BCI system, we proposed to reduce noise and artifact from the recording data to analyzing data. We used auditory stimuli instead of visual ones to eliminate the eye movement, unwanted visual activation, gaze control. We applied independent component analysis (ICA) algorithm to purify the sources which constructed the raw signals. One of the most famous spatial filter in BCI context is common spatial patterns (CSP), which maximize one class while minimize the other by using covariance matrix. ICA and CSP also do the filter job, as a raw filter and refinement, which increase the classification result of linear discriminant analysis (LDA).

Multiresolution Independent Component Analysis for Iris Identification

  • Noh, Seung-In;Kwanghuk Pae;Lee, Chulhan;Kim, Jaihie
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1674-1677
    • /
    • 2002
  • In this paper, the new method to extract the features of iris signals is proposed; Multiresolution ICA (M-ICA) provides good properties to represent signals with time-frequency. The conventional methods were to use the technique of filter bank analysis, while ICA is unsupervised learning algorithm using high-order statistics. M-ICA could make use of strengths of learn- ing method and multiresolution. Also, we performed comparative studies of different feature extraction techniques applied to personal identification using iris pat- tern. To measure goodness of methods, we use Fisher’s discriminant ratio to quantify the class-separability of features generated by various techniques.

  • PDF

Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation (독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출)

  • Jeon, Hak-Jae;Kim, Jeong-Do;Lim, Seung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

A Study on Blood Flow Measurement Method using Independent Component Analysis (독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구)

  • Cho, Seog-Bin;Lim, Dong-Seok;Baek, Kwang-Ryul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.2 s.314
    • /
    • pp.10-17
    • /
    • 2007
  • The echo signal on ultrasonic transducer is a mixed signal from tissues, blood vessel walls, blood cells and noise. In this mixed-signal, the signal reflected from tissues and blood vessel walls is called clutter. It is necessary to extract pure blood signal from this mixed-signal, when measuring blood flow velocity with medical ultrasonic system The quality of measured blood flow velocity is highly dependent on sufficient attenuation of the clutter signals. In this paper, we suggest a clutter rejection method using ICA For simulation, the echo signals are generated by Field n ultrasonic simulation program In this echo signals, independent signals are separated by using ICA Then the blood signal is obtained from the separated signals. Blood flow velocity is measured by 2D autocorrelation method. We compare ICA clutter rejection method with PCA-based eigen filter method using both measured blood flow velocity profiles by 2D autocorrelation. In simulation results, ICA clutter rejection method can be better applied measuring blood flow velocity in noisy echo signals.

Design of Filter to remove motion artifacts of PPG signal using Amplitude Modulation of Optical Power and Independent Components Analysis (광전력 진폭변조와 ICA를 이용한 PPG 신호의 동잡음 제거 필터 설계)

  • Lee, Ju-Won;Lee, Byoung-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.691-697
    • /
    • 2013
  • Recently, u-healthcare device is developed and commercialized for healthcare management and emergency medical. The kinds of the measurable biomedical signals on the device are electrocardiogram, skin temperature, pulse oxygen, heart rate, respiration, etc. Specially, the photoplethysmograph(PPG) signal of these signals is the important signal in measuring oxygen, heart rate and peripheral vascular compliance. The accuracy of PPG signal reduce from influence of the motion artifacts that generated from the movements of user or patient. Therefore, this study suggests a new method to remove the motion artifact that is using optical power modulation and ICA(Independent Component Analysis). For analyzing the proposed method, we used variety of noises made by artificially. In the results of experiments, the proposed method showed good performances than an adaptive filter.

The Classification Algorithm of Users' Emotion Using Brain-Wave (뇌파를 활용한 사용자의 감정 분류 알고리즘)

  • Lee, Hyun-Ju;Shin, Dong-Il;Shin, Dong-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.2
    • /
    • pp.122-129
    • /
    • 2014
  • In this study, emotion-classification gathered from users was performed, classification-experiments were then conducted using SVM(Support Vector Machine) and K-means algorithm. Total 15 numbers of channels; CP6, Cz, FC2, T7. PO4, AF3, CP1, CP2, C3, F3, FC6, C4, Oz, T8 and F8 among 32 members of the channels measured were adapted in Brain signals which indicated obvious the classification of emotions in previous researches. To extract emotion, watching DVD and IAPS(International Affective Picture System) which is a way to stimulate with photos were applied and SAM(Self-Assessment Manikin) was used in emotion-classification to users' emotional conditions. The collected users' Brain-wave signals gathered had been pre-processing using FIR filter and artifacts(eye-blink) were then deleted by ICA(independence component Analysis) using. The data pre-processing were conveyed into frequency analysis for feature extraction through FFT. At last, the experiment was conducted suing classification algorithm; Although, K-means extracted 70% of results, SVM showed better accuracy which extracted 71.85% of results. Then, the results of previous researches adapted SVM were comparatively analyzed.