Browse > Article
http://dx.doi.org/10.6109/jkiice.2013.17.3.691

Design of Filter to remove motion artifacts of PPG signal using Amplitude Modulation of Optical Power and Independent Components Analysis  

Lee, Ju-Won (안동과학대학교 의료공학과)
Lee, Byoung-Ro (경남과학기술대학교 전자공학과)
Abstract
Recently, u-healthcare device is developed and commercialized for healthcare management and emergency medical. The kinds of the measurable biomedical signals on the device are electrocardiogram, skin temperature, pulse oxygen, heart rate, respiration, etc. Specially, the photoplethysmograph(PPG) signal of these signals is the important signal in measuring oxygen, heart rate and peripheral vascular compliance. The accuracy of PPG signal reduce from influence of the motion artifacts that generated from the movements of user or patient. Therefore, this study suggests a new method to remove the motion artifact that is using optical power modulation and ICA(Independent Component Analysis). For analyzing the proposed method, we used variety of noises made by artificially. In the results of experiments, the proposed method showed good performances than an adaptive filter.
Keywords
u-healthcare; photoplethysmograph(PPG); motion artifacts; Independent Component Analysis; adaptive filter;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 V. Rialle, F. Dunchene, N. Noury, L. Bajolle, and J. Demongeot, "Health Smart Home : Information Technology for patients," Telemedicine and Journal and e-Health, vol. 8, no. 4, pp. 395-409, 2002.   DOI   ScienceOn
2 J. Lee, W. Jung, I. Kang, Y. Kim, G. Lee, "Design of filter to reject motion artifact of pulse oximetry," Computer Standards and Interfaces vol. 26 no. 3, pp. 241-249, 2004.   DOI   ScienceOn
3 H. W. Lee, J. W. Lee, W. G. Jung, and G. K. Lee, "The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals," International Journal of Control, Automation, and Systems, vol. 5, no. 6, pp. 701-706, 2007.
4 W. Y. Chung, S. Bhardwaj, A. Purwar, D. S. Lee, and R. Myllylae, "A fusion health monitoring using ECG and accelerometer sensors for elderly persons at home", Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, pp. 3818-3821, 2007.
5 H. H. Asada, H. H. Jiang, and P. Gibbs, "Active noise cancellation using MEMS accelerometers for motion-tolerant wearable bio-sensors," Proceedings of the 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Francisco. CA, pp. 2157-2160, 2004.
6 J. W. Lee and B. R. Lee, "Heart rate estimation based on PPG signal and histogram filter for mobile healthcare," International Journal of Maritime Information and Communication Sciences, vol. 8, no. 1, pp. 112-115, 2010.
7 K. K. Tremper and S. J. Baker, Pulse oximetry and oxygen transform, in Purse Oximetry, Berlin: Springer-Verlag, 1996.
8 J. W. Lee, J. H. Nam, "Design of filter to reject motion artifacts of PPG signal by Using Two Photosensors," J. Inf. Commun. Converg. Eng.. vol. 10, no. 1, pp. 91-95, 2012.
9 이한욱 외3, "생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리," 의공학회지, vol. 30, no. 6, pp. 503-509, 2009.   과학기술학회마을
10 A. J. Bell and T. J. Sejnowski, "An informationmaximization approach to blind separation and blind deconvolution," Neural Computation, vo1. 7, pp.1129-1159, 1995.