• Title/Summary/Keyword: ICA

Search Result 506, Processing Time 0.043 seconds

A CLASSIFICATION FOR PANCHROMATIC IMAGERY BASED ON INDEPENDENT COMPONENT ANALYSIS

  • Lee, Ho-Young;Park, Jun-Oh;Lee, Kwae-Hi
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.485-487
    • /
    • 2003
  • Independent Component Analysis (ICA) is used to generate ICA filter for computing feature vector for image window. Filters that have high discrimination power are selected to classify image from these ICA filters. Proposed classification algorithm is based on probability distribution of feature vector.

  • PDF

A Study on Blood Flow Measurement Method using Independent Component Analysis (독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구)

  • Cho, Seog-Bin;Lim, Dong-Seok;Baek, Kwang-Ryul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.2 s.314
    • /
    • pp.10-17
    • /
    • 2007
  • The echo signal on ultrasonic transducer is a mixed signal from tissues, blood vessel walls, blood cells and noise. In this mixed-signal, the signal reflected from tissues and blood vessel walls is called clutter. It is necessary to extract pure blood signal from this mixed-signal, when measuring blood flow velocity with medical ultrasonic system The quality of measured blood flow velocity is highly dependent on sufficient attenuation of the clutter signals. In this paper, we suggest a clutter rejection method using ICA For simulation, the echo signals are generated by Field n ultrasonic simulation program In this echo signals, independent signals are separated by using ICA Then the blood signal is obtained from the separated signals. Blood flow velocity is measured by 2D autocorrelation method. We compare ICA clutter rejection method with PCA-based eigen filter method using both measured blood flow velocity profiles by 2D autocorrelation. In simulation results, ICA clutter rejection method can be better applied measuring blood flow velocity in noisy echo signals.

초대석 김선배 ICA 원장

  • Gwon, Gyeong-Hui
    • Digital Contents
    • /
    • no.7 s.146
    • /
    • pp.14-15
    • /
    • 2005
  • 김선배 전 현대정보기술 대표이사가 지난달 1일자로 한국정보통신수출진흥센터(ICA) 제2대 원장에 취임했다. 김 신임 원장은“앞으로 ICA가 정보통신분야의 국제협력에 중추적인 역할을 할 수 있도록 노력하겠다”고 말했다. 김 신임 원장은 금융ㆍ건설ㆍ정보통신 등 다양한 분야에서 전문성을 쌓아왔고 현대정보기술 대표이사와 한국소프트웨어산업협회장 등을 역임했다.

  • PDF

Speaker Adaptation using ICA-based Feature Transformation (ICA 기반의 특징변환을 이용한 화자적응)

  • Park ManSoo;Kim Hoi-Rin
    • MALSORI
    • /
    • no.43
    • /
    • pp.127-136
    • /
    • 2002
  • The speaker adaptation technique is generally used to reduce the speaker difference in speech recognition. In this work, we focus on the features fitted to a linear regression-based speaker adaptation. These are obtained by feature transformation based on independent component analysis (ICA), and the transformation matrix is learned from a speaker independent training data. When the amount of data is small, however, it is necessary to adjust the ICA-based transformation matrix estimated from a new speaker utterance. To cope with this problem, we propose a smoothing method: through a linear interpolation between the speaker-independent (SI) feature transformation matrix and the speaker-dependent (SD) feature transformation matrix. We observed that the proposed technique is effective to adaptation performance.

  • PDF

Stent-Assisted Coil Trapping in a Manual Internal Carotid Artery Compression Test for the Treatment of a Fusiform Dissecting Aneurysm

  • Seung, Won-Bae;Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.5
    • /
    • pp.296-300
    • /
    • 2012
  • Internal carotid artery (ICA) trapping can be used for the treatment of giant intracranial aneurysms, blood blister-like aneurysms, and fusiform dissecting aneurysms. Fusiform dissecting aneurysms are challenging to treat surgically and endovascularly because of no definite neck and critical perforators. Surgical or endovascular trapping of the ICA with or without an extracranial-intracranial bypass has commonly been used as an effective method to treat these lesions, but balloon test occlusion (BTO) must be performed. Here, we report a case of a ruptured fusiform dissecting aneurysm of the distal ICA, which was successfully treated using an endovascular ICA trapping with a manual ICA compression test instead of BTO.

Predicting Unknown Composition of a Mixture Using Independent Component Analysis

  • Lee, Hye-Seon;Park, Hae-Sang;Jun, Chi-Hyuck
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.127-134
    • /
    • 2005
  • A suitable representation for the conceptual simplicity of the data in statistics and signal processing is essential for a subsequent analysis such as prediction, pattern recognition, and spatial analysis. Independent component analysis (ICA) is a statistical method for transforming an observed high-dimensional multivariate data into statistically independent components. ICA has been applied increasingly in wide fields of spectrum application since ICA is able to extract unknown components of a mixture from spectra. We focus on application of ICA for separating independent sources and predicting each composition using extracted components. The theory of ICA is introduced and an application to a metal surface spectra data will be described, where subsequent analysis using non-negative least square method is performed to predict composition ratio of each sample. Furthermore, some simulation experiments are performed to demonstrate the performance of the proposed approach.

  • PDF

Evaluating Apparatus for the ICA-Aided Mixel Analysis of Periodical Hyperspectral Images

  • Shimozato, Masao;Kosaka, Naoko;Uto, Kuniaki;Kosugi, Yukio
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.411-413
    • /
    • 2003
  • In the images obtained from high altitude, several materials are mixed in one pixel and observed as a mixel. It makes difficult to separate the value of pure materials from obtained data. As mixel analysis, various techniques using Independent Component Analysis (ICA) and wavelet analysis, etc, were proposed. In this study, we applied to the ICA technique to real data collected by hyperspectral line sensor. Real data came under the influence of several effects regarded as basin on the convolution. We show that combining the ICA method with deconvolution improve it's estimation ability.

  • PDF

A DESIGN OF INTERSECTION COLLISION AVOIDANCE SYSTEM BASED ON UBIQUITOUS SENSOR NETWORKS

  • Kim, Min-Soo;Lee, Eun-Kyu;Jang, Byung-Tae
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.749-752
    • /
    • 2005
  • In this paper, we introduce an Intersection Collision Avoidance (ICA) system as a convergence example of Telematics and USN technology and show several requirements for the ICA system. Also, we propose a system design that satisfies the requirements of reliable vehicular data acquisition, real-time data transmission, and effective intersection collision prediction. The ICA system consists of vehicles, sensor nodes and a base station that can provide drivers with a reliable ICA service. Then, we propose several technological solutions needed when implementing the ICA system. Those are about sensor nodes deployment, vehicular information transmission, vehicular location data acquisition, and intersection collision prediction methods. We expect this system will be a good case study applied to real Telematics application based on USN technology.

  • PDF

Automatic P300 Detection using ICA with Reference (Reference를 갖는 ICA를 이용한 자동적 P300 검출)

  • Park, Heeyoul;Park, Seungjin
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.193-195
    • /
    • 2003
  • The analysis of EEG data is an important task in the domain of Brain Computer Interface (BCI). In general, this task is extremely difficult because EEG data is very noisy and contains many artifacts and consists of mixtures of several brain waves. The P300 component of the evoked potential is a relatively evident signal which has a large positive wave that occurs around 300 msec after a task-relevant stimulus. Thus automatic detection of P300 is useful in BCI. To this end, in this paper we employ a method of reference-based independent component analysis (ICA) which overcomes the ordering ambiguity in the conventional ICA. We show here. that ICA incorporating with prior knowledge is useful in the task of automatic P300 detection.

  • PDF

Image Classification Method using Independent Component Analysis and Normalization (독립성분해석과 정규화를 이용한 영상분류 방법)

  • Hong, Jun-Sik;Ryu, Jeong-Woong
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.9
    • /
    • pp.629-633
    • /
    • 2001
  • In this paper, we improve noise tolerance in image classification by combining ICA(Independent Component Analysis) with Normalization. When we add noise to the raw image data the degree of noise tolerance becomes N(0, 0.4) for PCA and N(0, 0.53) for ICA. However, when we use the preprocessing approach the degree of noise tolerance after Normalization becomes N(0, 0.75), which shows the improvement of noise tolerance in classification.

  • PDF