• Title/Summary/Keyword: I60

Search Result 4,960, Processing Time 0.033 seconds

APPROXIMATION OF RELIABILITY IMPORTANCE FOR CONTINUUM STRUCTURE FUNCTIONS

  • Lee, SeungMin;Kim, RakJoong
    • Korean Journal of Mathematics
    • /
    • v.5 no.1
    • /
    • pp.55-60
    • /
    • 1997
  • A continuum structure function(CSF) is a non-decreasing mapping from the unit hypercube to the unit interval. The reliability importance of component $i$ in a CSF at system level ${\alpha}$, $R_i({\alpha})$) say, is zero if and only if component $i$ is almost irrelevant to the system at level ${\alpha}$. A condition to check whether a component is almost irrelevant to the system is presented. It is shown that $R^{(m)}_i({\alpha}){\rightarrow}R_i({\alpha})$ uniformly as $m{\rightarrow}{\infty}$ where each $R^{(m)}_i({\alpha})$ is readily calculated.

  • PDF

Insulin-Like Growth Factor-I Induces Androgen Receptor Activation in Differentiating C2C12 Skeletal Muscle Cells

  • Kim, Hye Jin;Lee, Won Jun
    • Molecules and Cells
    • /
    • v.28 no.3
    • /
    • pp.189-194
    • /
    • 2009
  • The modulating effect of IGF-I on the regulation of AR gene expression and activation in skeletal muscle cells remains poorly understood. In this study, the effects of IGF-I treatment on AR induction and activation in the absence of AR ligands were examined. Differentiating C2C12 cells were treated with different concentrations (0-250 ng/ml) of IGF-I or for various periods of time (0-60 min) of 250 ng/ml IGF-I. Treatment of C2C12 cells with IGF-I resulted in a dose- and time-dependent increase in total AR and phosphorylated AR (Ser 213). IGF-I treatment also led to significantly increased AR mRNA expression when compared with the control. The levels of skeletal ${\alpha}-actin$ and myogenin mRNA, known target genes of AR, were also significantly upregulated after 5 or 10 min of treatment with IGF-I. Confocal images revealed that IGF-I stimulated nuclear localization of AR in the absence of ligands. In addition, an electrophoretic mobility shift assay indicated that IGF-I stimulated the AR DNA binding activity in a time-dependent manner. The present results suggest that IGF-I stimulates the expression and activation of AR by ligand-independent mechanism in differentiating C2C12 mouse skeletal muscle cells.

Effects of Varied Resistance Training Intensities and Rest Intervals Between Sets on iEMG, Repetition Rate, and Total Work (저항운동의 운동 강도별 세트 간 휴식시간 차이가 근수축력, 반복횟수 및 총운동량에 미치는 영향)

  • Song, Sang-Hyup;Lee, Young-Soo;Han, Aleum;Kim, Si-Young;Go, Sung-Sik
    • 한국체육학회지인문사회과학편
    • /
    • v.51 no.5
    • /
    • pp.639-647
    • /
    • 2012
  • The purpose of this study was to examine the effects of varied resistance training intensities and rest intervals between training sets on integral electromyography (iEMG), repetition rate, and total work. All subjects, 14 college students, were tested one repetition maximum (1RM). Then, all subjects were weekly tested with 9 practice procedures, composed of diverse intensities (60, 75, 90% of 1RM) and rest intervals (1, 3, 5 min). As results show, to maintain the same load and target repetition maximum for an untrained person, muscular power training (90% of 1RM), muscular hypertrophy training (75% of 1RM), and muscular endurance training (60% of 1RM) should be applied with 5 min or longer rest interval periods for 3 training sets. In addition, 2 training sets with 3 min rest intervals and a set with an 1 min rest interval were capable by the subjects. Thus, at least 3 min or longer rest intervals should be applied to maintain multiple training sets. In case for muscular endurance training, which requires shorter rest intervals, the intensity of exercise should be adjusted to 60% of 1RM or less. In conclusion, depending on diverse purposes of resistance training such as improving muscular power, muscular hypertrophy, or muscular endurance, appropriate exercise intensity and rest intervals should be applied.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

RF Interconnection Technique of MMIC Microwave Switch Matrix for 60dB On-to-off Isolation (60dB 온-오프 격리도를 위한 통신 위성 중계기용 MMIC MSM의 RF 결합 방법)

  • Noh, Y.S.;Ju, I.K.;Yom, I.B.
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.111-114
    • /
    • 2005
  • The isolation performance of the S-band single-pole single-throw (SPST) monolithic microwave integrated circuit (MMIC) switch with two different RF-interconnection approaches, microstrip and grounded coplanar waveguide (GCPW) lines, are investigated. On-to-off isolation is improved by 5.8 dB with the GCPW design compared with the microstrip design and additional improvement of 6.9dB is obtained with the coplanar wire-bond interconnection (CWBI) at 3.4 GHz. The measured insertion loss and third-order inter-modulation distortion (IMD3) are less than 2.43 dB over 2.5 CHz $\sim$ 4 GHz and greater than 64 dBc.

  • PDF

Evaluation of Heavy Metal Pollution in Soil on the Playgrounds for Children in I area (I시 어린이 놀이터의 토양 중 중금속 오염에 관한 연구)

  • 이충대;이윤진;조남영
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.57-62
    • /
    • 2001
  • The study was conducted to measure the heavy metal pollution of soils at the playground for children and to investigate the characteristics of heavy metals distribution I city. The studied area was divided into two: the residential area and the industrial area. The samples of the sands and soils were collected from both areas. The results were obtained as follows. All average concentration of 6 different heavy metals was found to be lower than the standard of soil pollution. Zn, Pb and cu concentrations were higher than other species of heavy metals. The contents of heavy metals in the soil were higher than the sands. The average contents of Zn, Pb, Cu, As, Hg and Cd in soil were 38.36, 9.53, 7.31, 0.03, 0.18 and 0.09 mg/kg respectively. Comparing with the residential area, heavy metal concentrations of the industrial area were 4.60, 1.49, 2.60 and 4.29 times for Zn, Pb, Hg and Cd in soils, respectively.

  • PDF

Microstructure of Polypropylene Prepared with Kaminsky Catalyst System (Kaminsky 촉매계로 제조한 폴리프로필렌의 미세구조)

  • Lee, Cheal-Gyu
    • Analytical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.203-209
    • /
    • 1996
  • Kaminsky catalyst system($Et(Ind)_2ZrCl_2$ and MAO(methylaluminoxane)) was prepared. Propylene was polymerized at $60^{\circ}C$ in this system. The microstructure was studied by using the $^{13}C$ NMR spectrometer. From the $^{13}C$ NMR data, the 2, 1-insertion of propylene was controlled stereospecific by Kaminsky catalyst due to the structures of meso and racemo I. After the 2, 1-insertion of propylene, 1, 2-insertion of the chain end was less stereospecifically controlled by the catalyst.

  • PDF

Effect of Microstructure on the Properties of High Strength Hardened Cement Paste(I) (고강도 시멘트 경화체의 특성에 미치는 미세구조의 영향(I))

  • 김정환;최상흘;한기성
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.7
    • /
    • pp.861-868
    • /
    • 1990
  • Investigation for the preparation of high strength hardened cement paste using ordinary portland cement, hydroxypropyl methyl cellulose(HPMC) with SiC powder was carried out. The cement paste was mixed with 0.1 of water cement ratio by twin roll mill and cured 60 days in humidity chamber. The hydration degree of cement paste cured with W/C=0.1 in 60 days was about 30% and most pores in the paste were found to be existed as gel pores of diameter less than 0.01㎛. The maximum flexural strength of hardened cement paste was about 960kg/㎠. When the SiC powder was added to the paste, the flexural strength was 1000∼1100kg/㎠ and the Young's modulus was 8∼9×105kg/㎠.

  • PDF

Structural damage identification using gravitational search algorithm

  • Liu, J.K.;Wei, Z.T.;Lu, Z.R.;Ou, Y.J.
    • Structural Engineering and Mechanics
    • /
    • v.60 no.4
    • /
    • pp.729-747
    • /
    • 2016
  • This study aims to present a novel optimization algorithm known as gravitational search algorithm (GSA) for structural damage detection. An objective function for damage detection is established based on structural vibration data in frequency domain, i.e., natural frequencies and mode shapes. The feasibility and efficiency of the GSA are testified on three different structures, i.e., a beam, a truss and a plate. Results show that the proposed strategy is efficient for determining the locations and the extents of structural damages using the first several modal data of the structure. Multiple damages cases in different types of structures are studied and good identification results can be obtained. The effect of measurement noise on the identification results is investigated.

Reheating Process of Semi-Solid Aluminum Alloy (반융용알루미늄재료의 재가열공정)

  • 강성수;도영진;강충길
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.06a
    • /
    • pp.16-27
    • /
    • 1997
  • A semi-solid forming has a lot of advantages compared to the die casting, squeeze costing and convenctional forging, therefore, semi-solid forming process are now becoming of industial interest for the production of metal components and metal matrix composites. However, the material behaviour in the semi-solid temperature range is not sufficiently known although it controls the whole process through forces and geometry evolutions bcause the behaviour of metal slurries is complex. The semi-solid materials(SSM) fabricated under electric-magnetic stirring condition is necessary to be applicate in forming process. A reheating conditions were studied with the reheating time, holing time and reheating temperatures. The microstructure of SSM (which specimen size:d 40${\times}$i60) on condition of heating time 10min and heating temperature 590$^{\circ}C$ is most globular and finest one. The microstructure of SSM(specimen size:d75${\times}$i60) reheated under the three step reheating conditions is most globular and finest.

  • PDF