• Title/Summary/Keyword: I-scan

Search Result 451, Processing Time 0.02 seconds

Spontaneous Resolution Rate and Predictive Factors of Resolution in Children with Primary Vesicoureteral Reflux (소아에서 일차성 방광요관역류의 자연소실율 및 관련 인자)

  • Kang, Eun-Young;Kim, Min-Sun;Kwon, Keun-Sang;Park, Eun-Hye;Lee, Dae-Yeol
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.74-82
    • /
    • 2007
  • Purpose : To analyze the clinical characteristics, spontaneous resolution rate and predictive factors of resolution in children with primary vesicoureteral reflux(VUR). Methods : Between October 1991 and July 2003, 149 children diagnosed with primary VUR at Chonbuk National University Hospital were reviewed retrospectively. All of the patients were maintained on low-dose antibiotic prophylaxis and underwent radionuclide cystograms at 1 year intervals over 3 years after the initial diagnosis of VUR by voiding cystourethrogram was made. Results : The median time to resolution of VUR was 24 months and the total 3 year-cumulative resolution rate of VUR was 61.7%. The following variables were associated with resolution of VUR according to univariate analysis-; age<1 year, male gender, mild grade of reflux, unilateral reflux, congenital hydronephrosis as clinical presentation at time of diagnosis of VUR, absence of focal defects in the renal scan at diagnosis, absence of recurrent UTI, renal scars and small kidney during follow-up. After adjustment by Cox regression model, five variables remained as independent predictors of VUR resolution; age<1 yew, relative risk 1.77(P<0.05), VUR grade I+II 2.98(P<0.05), absence of renal scars 2.23(P<0.05), and absence of small kidney 5.20(P<0.01) during follow-up. Conclusion : In this study, spontaneous resolution rate of VUR, even high grade reflux, is high in infants during medical management, and it was related to age, reflux grade at diagnosis, absence of renal scars and small kidney during follow-up. Therefore early surgical intervention should be avoided and reserved for the selected groups.

  • PDF

Properties of Indium Tin Oxide Thin Films According to Oxygen Flow Rates by γ-FIB System (γ-FIB 시스템을 이용한 산소 유량 변화에 따른 산화인듐주석 박막의 특성 연구)

  • Kim, D.H.;Son, C.H.;Yun, M.S.;Lee, K.A.;Jo, T.H.;Seo, I.W.;Uhm, H.S.;Kim, I.T.;Choi, E.H.;Cho, G.S.;Kwon, G.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.333-341
    • /
    • 2012
  • Indium Tin Oxide (ITO) thin films were prepared by RF magnetron sputtering with different flow rates of $O_2$ gas from 0 to 12 sccm. Electrical and optical properties of these films were characterized and analyzed. ITO deposited on soda lime glass and RF power was 2 kW, frequency was 13.56 MHz, and working pressure was $1.0{\times}10^{-3}$ Torr, Ar gas was fixed at 1,000 sccm. The transmittance was measured at 300~1,100 nm ranges by using Photovoltaic analysis system. Electrical properties were measured by Hall measurement system. ITO thin films surface were measured by Scanning electron microscope. Atomic force microscope surface roughness scan for ITO thin films. ITO thin films secondary electron emission coefficient(${\gamma}$) was measured by ${\gamma}$-Focused ion beam. The resistivity is about $2.4{\times}10^{-4}{\Omega}{\cdot}cm$ and the weighted average transmittance is about 84.93% at 3 sccm oxygen flow rate. Also, we investigated Work-function of ITO thin films by using Auger neutralization mechanism according to secondary electron emission coefficient(${\gamma}$) values. We confirmed secondary electron emission peak at 3 sccm oxygen flow rate.

Lung Uptake of $^{99m}Tc-sestamibi$ during Routine Gated Exercise SPECT Imaging : Comparison with Left Ventricular Ejection Fraction and Severity of Perfusion Defect (일상적인 운동 부하 게이트 심근 관류 SPECT에서 $^{99m}Tc-sestamibi$ 폐섭취 : 좌심실 구혈률과 관류 결손 정도와의 비교)

  • Jeong, Shin-Young;Lee, Jae-Tae;Bae, Jin-Ho;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.83-93
    • /
    • 2003
  • Background: Lung-to-heart uptake ratio (LHR) in $^{201}Tl-chloride$ myocardial perfusion scan is believed to be a reliable marker for left ventricular (LV) dysfunction, but the clinical value of LHR is controversial for $^{99m}Tc-MIBI$ imaging. Furthermore, most of results suggesting lung uptake of $^{99m}Tc-MIBI$ as a potential marker for LV dysfunction used immediate post-stress images, instead of routine images acquired 1 hour after tracer injection. The goal of our study was to investigate whether LHR evaluated with routine gated $^{99m}Tc-MIBI$ imaging can reflect the degree of perfusion defect or left ventricular performance. Subjects and Methods: 241 patients underwent exercise $^{99m}Tc-MIBI$ myocardial SPECT were classified into normal myocardial perfusion (NP, n=135) and abnormal myocardial perfusion (AP, n=106) group according to the presence of perfusion defect. LHR was calculated from anterior projection image taken at 1-hour after injection. Two legions of interest (ROIs) were placed on left lung above LV and on myocardium showing the highest radioactivity. Subjects were classified by left ventricular ejection fraction (LVEF), as Gr-I: >50%, Gr-II: 36-50%, Gr-III: <36% and by summed stress score (SSS), as Gr-A: <4, Gr-B: 4-8, Gr-C: 9-13, Gr-D: >13, LHR was compared among these groups. Results: In NP group(n=135), LHR, were higher in men than women ($men:\;0.311{\pm}0.03,\;women:\;0.296{\pm}0.03,\;p<0.05$). Significant difference, in LHR were found between NP and AP groups both for men and women ($men:\;0.311{\pm}0.03\;vs\;.\;0.331{\pm}0.06,\;women:\;0.296{\pm}0.03\;vs.\;0.321{\pm}0.07.\;p<0.05$). There were weak negative correlation between LHR and LVEF (r=-0.342, p<0.05) and weak positive correlation between LHR and SSS (r=0.478, p<0.05) in men, but not in women (LVEF: r=-0.279, p=0.100, SSS: r=0.276, p=0.103). Increased LHR was defined when for more than mean + 2SD value ($men{\geq}0.38,\;women{\geq}0.37$) of the LHR of the subject with normal perfusion. Increased LHR were observed more frequently in subjects with lower LVEF (Gr-I: 11.1%, Gr-II: 27.0%, Gr-III: 35.4%, p<0.05) and higher SSS(Gr-A: 14.0%, Gr-B: 5.7%, Gr-C: 18.2%, Gr-D: 40.7%, p<0.05). Conclusions: LHRs obtained from routine $^{99m}Tc-MIBI$ gated SPECT images were weakly correlated with LVEF and perfusion defect. Although significant overlaps were observed between normal and abnormal perfusion group, LHRs could be used as an indirect marker of severe perfusion defect or reduced left ventricular function.

Three-dimensional Model Generation for Active Shape Model Algorithm (능동모양모델 알고리듬을 위한 삼차원 모델생성 기법)

  • Lim, Seong-Jae;Jeong, Yong-Yeon;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.28-35
    • /
    • 2006
  • Statistical models of shape variability based on active shape models (ASMs) have been successfully utilized to perform segmentation and recognition tasks in two-dimensional (2D) images. Three-dimensional (3D) model-based approaches are more promising than 2D approaches since they can bring in more realistic shape constraints for recognizing and delineating the object boundary. For 3D model-based approaches, however, building the 3D shape model from a training set of segmented instances of an object is a major challenge and currently it remains an open problem in building the 3D shape model, one essential step is to generate a point distribution model (PDM). Corresponding landmarks must be selected in all1 training shapes for generating PDM, and manual determination of landmark correspondences is very time-consuming, tedious, and error-prone. In this paper, we propose a novel automatic method for generating 3D statistical shape models. Given a set of training 3D shapes, we generate a 3D model by 1) building the mean shape fro]n the distance transform of the training shapes, 2) utilizing a tetrahedron method for automatically selecting landmarks on the mean shape, and 3) subsequently propagating these landmarks to each training shape via a distance labeling method. In this paper, we investigate the accuracy and compactness of the 3D model for the human liver built from 50 segmented individual CT data sets. The proposed method is very general without such assumptions and can be applied to other data sets.

The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI (뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교)

  • Kim, Tae;Choe, Bo-Young;Kim, Euy-Neyng;Suh, Tae-Suk;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Purpose : The purpose of this study was to find the optimum TE value for enhancing $T_2^{*}$ weighting effect and minimizing the SNR degradation and to compare the BOLD effects according to the changes of TE in 1.5T and 3.0T MRI systems. Materials and Methods : Healthy normal volunteers (eight males and two females with 24-38 years old) participated in this study. Each volunteer was asked to perform a simple finger-tapping task (sequential opposition of thumb to each of the other four fingers) with right hand with a mean frequency of about 2Hz. The stimulus was initially off for 3 images and was then alternatively switched on and off for 2 cycles of 6 images. Images were acquired on the 1.5T and 3.0T MRI with the FLASH (fast low angle shot) pulse sequence (TR : 100ms, FA : $20^{\circ}$, FOV : 230mm) that was used with 26, 36, 46, 56, 66, 76ms of TE times in 1.5T and 16, 26, 36, 46, 56, 66ms of TE in 3.0T MRI system. After the completion of scan, MR images were transferred into a PC and processed with a home-made analysis program based on the correlation coefficient method with the threshold value of 0.45. To search for the optimum TE value in fMRI, the difference between the activation and the rest by the susceptibility change for each TE was used in 1.5T and 3.0T respectively. In addition, the functional $T_2^{*}$ map was calculated to quantify susceptibility change. Results : The calculated optimum TE for fMRI was $61.89{\pm}2.68$ at 1.5T and $47.64{\pm}13.34$ at 3.0T. The maximum percentage of signal intensity change due to the susceptibility effect inactivation region was 3.36% at TE 66ms in 1.5T 10.05% at TE 46ms in 3.0T, respectively. The signal intensity change of 3.0T was about 3 times bigger than of 1.5T. The calculated optimum TE value was consistent with TE values which were obtained from the maximum signal change for each TE. Conclusion : In this study, the 3.0T MRI was clearly more sensitive, about three times bigger than the 1.5T in detecting the susceptibility due to the deoxyhemoglobin level change in the functional MR imaging. So the 3.0T fMRI I ore useful than 1.5T.

  • PDF

The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures (PET 검사 프러시저별 방사선 차폐기구의 유용성 평가)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Jeong, Yo-Cheon;Kim, Sang-Wook;Seo, Il-Teak;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 2010
  • Purpose: he use of PET scanners and the number of patient in Korea have been increased for recent several years dramatically. For this reason, technologists have more possibilities to be exposed to the radiation. The hospitals using PET scanners should make an effort to reduce the radiation exposure dose. The purpose of this study was to evaluate the radiation exposure does when using radiation shielding devices. The evaluation was performed through questionnaire survey and experiment. Materials and Methods: First, the technologists who had experience working in PET center in 2008-2009 were surveyed with questionnaire and TLD Figures, personal opinion of utilization of radiation shielding devices are analyzed. Second, we measured the shielding rate of shielding devices which have been using in PET study procedures. We divided the procedures into four steps; distribution, moving, injection of $^{18}F$-FDG and patient setup. Results: First, the results of this survey, using of L-block+Syringe shield, L-block, Syringe shield, No shield during the injection, were each 58.5%, 20%, 9%, 12.3%. The TLD values according to utilization of radiation shield, using both L-block+Syringe Shield and L-block showed the lower TLD values, and Syringe shield only or No shield showed the higher TLD values. Second, the results of experiments according to PET study procedures measured the shielding rates as follows. The shielding rates during the distribution using L-block, L-block+Apron shield were measured 97.4%, 97.7%. The shielding rates during the $^{18}F$-FDG delivery to the injection room using mobile Syringe shield, Syringe holder, Syringe shield carrier were each 81.7%, 98.9%, 99.7%. The shielding rates during the injection using Syringe shield, L-block, L-block+Syringe shield were measured each 51.9%, 98.3%, 98.7%. The shielding rates of Apron were measured in each 30, 60, 90, 120, 150 cm distance. The measurement were each 16.9%, 14.2%, 16.6%, 17.1%, 18.1%, 18.6%. Conclusion: The most effective method for radiation shielding is to using L-block during the $^{18}F$-FDG distribution and Syringe shield carrier during in moving $^{18}F$-FDG. For the $^{18}F$-FDG injection, L-block+Syringe shield have to be used. The shielding effect of Apron has shown average 16.4%. According to the survey of questionnaire, the operators recognized well risk of the radiation exposure but, tended ignore in working. The radiation dose according to recognition of radiation exposure risk was not relevant. but radiation dose according to utilization of radiation shield lower the more use it. The main reason of no use of shielding devices is cumbersome, 55% of the respondents answered. I'm sure, by use of radiation shield in all PET procedure, radiation exposure will be reduced considerably.

  • PDF

Comparison of X-ray VCUG with RI VCUG for Diagnosing VUR in Children (소아의 방광 요관 역류 진단시 X-ray 배뇨성 방광 요도 조영술(X-ray VCUG)과 방사성 동위원소 배뇨성 방광 요도 조영술(RI VCUG)의 비교)

  • Hong Hyun-Soook;Choi Deuk-Lin;Kim Eun-Mi;Kim Sung-Jun
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.187-195
    • /
    • 1999
  • Purpose : VUR is state where urine regurge from bladder to ureter and kidney. It is shown in about 1/3 of urinary tract infection patients and it is classified as grade I to V. We compared results from RI VCUG(Radiisotope voiding cystourethrography) and X-ray VCUG which used in diagnosing VUR in children, to evaluate which is better in diagnosing VUR in children. Methods : 41 Patients(19 males, 21 females), who visited Pediatric department, Soonchunhyang university Hospital from peroid of 1991. January to 1998. July for recurrent urinary tract infection or abnormalities in ultrasonogams, were enrolled in the study. The age ranged from 9 months to 17 years and mean age was 5 1/2 years. Both RI VCUG and X-ray VCUG were done and follow-up test of urine culture, renal ultrasonogram and RI VCUG were done every month, every 3 month and every 6 month, respectively to observe the disappearance of VUR and evaluated the prognosis. Results : 24 patients had taken RI VCUG and 17(70.1%) patients showed positive result. 22 patients had taken X-ray VCUG and 9(40.1%) patients showed findings of VUR. 17 patients had taken both tests and 14 patients showed positive result in RI VCUG and 6 of these patients also showed reflux in X-ray VCUG. 3 patients who showed negative in RI VCUG, showed negative also in X-ray VCUG. For prognosis, resolution and scar formation was shown in 8 patients each. Persistent VUR was shown in 6 patients and 2 of these patients VUR was corrected by operation, 1 patient showed decreased renal function, and 1 patient was not follwed up. 8 of 9 patients who showed findings of VUR on DMSA scan formed a scar and 8 patients who showed no findings of VUR didn't form a scar. Urine culture was positive in 17 of 19 patients with VUR. Positive rate in urine culture was higher than that of patients with no VUR who showed positivity in 15 of 21 patients for urine culture. E. coli was most common organism and the period free of UTI was 14 months in VUR patients and it was shorter compared to patients without VUR which was 26 months. Conclusion : In diagnosing VUR in children, the positive rate was higher in RI VCUG than X-ray VCUG. Therefore, in early diagnosis when VUR is suspicious but not shown in X-ray VCUG, RI VCUG should be done and it will help to make accurate diagnosis.

  • PDF

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

Comparative Volume Measuring Methods According to the Tumor Characters in PET/CT (PET/CT 검사에서 종양의 특성에 따른 체적 측정 방법 비교)

  • Choi, Yong Hoon;Ban, Yung Gak;Oh, Shin Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.52-58
    • /
    • 2016
  • Purpose Recent retrospective studies are being actively conducted to analyze the survival of patients with SUVmax, MTV, TLG, such as information from a variety of PET originating. However, there is no clear way is difficult to accurately measure the volume of the tumor may be the difference between the caster is raised. In this study, to evaluate compare the volume measuring methods according to the characteristics of the tumor. Materials and Methods 18F-saline to fill the NEMA IEC Body Phantom insert the volume of balance and imbalance in phantom were acquired to the Biograph truepoint 40 (Siemens medical system, Germany) PET/CT scanner. The ratio of the volume and Background was acquired as 3.0, 5.0, 8.0, 18, 40. Clinical patients were randomly selected 120 people in staging patients with cancer of the digestive system from the year 2010 until the year 2014. Measurement methods were used a 40% threshold, 50% threshold and gradient segmentation technique, i.e. PET EDGE. Five years of experience of the two radio-technologist and one doctor was measured by repeated three times. Analysis methods were Intraclass correlation coefficient and Pearson correlation. Results In Phantoms, the 40% threshold method gave the best concordance between measured and actual volumes (r = 0.992, 0.997). In clinical patient outcome agreement between observers EDGE it is as high as 0.999 (CI: 0.998-0.999). And there were no statistical significance of the difference between the measurements (P = 0.620). 40% threshold method showed the best correlation between the measurements (r = 0.953). Increasing the ratio of tumor to background decreased the influence of a measuring method. Conclusion How to measure volume of the tumor in the patient was clinically most useful is 50% and the lowest impact on the characteristics of the tumor. Therefore, to reduce the background of the patients in PET/CT scan, it should be required research and effort.

  • PDF

Lower Extremity Edema in Terminal Cancer Patients (말기 암 환자에서의 하지 부종)

  • Shim, Byoung-Yong;Hong, Seok-In;Park, Ji-Chan;Hong, Sug-Hui;Choi, Gang-Heun;Cho, Hong-Joo;Kim, Seon-Young;Han, Sun-Ae;Lee, Ok-Kyung;Kim, Hoon-Kyo
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.2
    • /
    • pp.152-155
    • /
    • 2005
  • Purpose: The lower extremity edema (LEE) is a common distressful symptom in advanced cancer patients and is hard to manage. We analyze the characteristics of LEE in patients with advanced cancer to provide the basic information of causes and adequate management. Methods: Physical examination, assessment of the location and severity of edema, blood chemistry (albumin, creatinine), Doppler Sono for patients with suspecting deep vein thrombosis (DVT), and abdomen CT scan for patient with suspecting lymph edema were performed. Severity of edema was classified according to NCI lymph edema scaling and improvement was defined as lowering at least 1 grade of edema after management. Results: Among 154 patient who had been admitted to Hospice Ward from Mar 2003 to Jan 2004, 33 had LEE, and 6 had both upper extremity edema and LEE except generalized edema. Their underlying cancers were stomach (7), lung (6), biliary tract (5), liver (5), colorectal (5), pancreas (2), and others (9). There were 12 patient with grade I, 20 patients with grade II, and 7 patients with grade III edema. The causes were hypoalbuminemia (11), lymph edema (10), DVT (7), obstruction of inferior vena cava (IVC) or portal vein (6), and dependent edema (5). The common managements were including leg elevation and diuretics. Elastic stocking was applied for patients with DVT and leg massage and pneumatic compression was used for lymph edema. The 2/3 patients were improved after management. Conclusion: The incidence of LEE in terminal cancer pts was high (25.3%) and their causes were variable including lymph edema, DVT, hypoalbuminemia and dependent edema. Active noninvasive management according to causes could result in good palliation.

  • PDF