• Title/Summary/Keyword: I-V test

Search Result 736, Processing Time 0.027 seconds

An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test (재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가)

  • Kwon, Il-Hyun;Na, Sung-Hun;Song, Gee-Wook;Yu, Hyo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

Clinical study on treatment of HIVD of lumbar spine using Scolopendrid herbal acupuncture (오공약침(蜈蚣藥針)을 이용한 요추간판탈출증(腰椎間板脫出症) 치료(治療)의 임상적(臨床的) 연구(硏究))

  • Park, So-Yeong;Lee, Gyeong-Yun;Choe, Hoe-Gang;So, Gi-Suk;Lee, Jong-Deok;Kim, Seong-Cheol;Go, Gang-Hun
    • Journal of Pharmacopuncture
    • /
    • v.4 no.3
    • /
    • pp.47-57
    • /
    • 2001
  • Objective: This study is performed for the purpose of examining into the efficacy of the scolopendrid(Scolopendra morsitans L) which has been used among the Korean people for the H.I.V.D of lumbar spine. Methods & Results: Using the herbal acupuncture made of scolopendrid(Scolopendra morsitans L), we treated the 10 H.l. V.D patients for 1 week and operated 4 pre and post treatment test ; D.I.T.I, 6 kind of physical test, Oswestry disability index, and self-conscious pain rate. Trough Lite test, we saw 50-100% of efficacy rate in each test. Otherwise, only 5 of the 7 point in D.I.T.I and self-conscious pain rate showed statistically valuable change. Conclusion: we brought to the conclusion that the scolopendrid herbal acupuncture has possibility to be efficient to cure the H.I.V.D patients. So we suggest the possibility to use this new remedy for the H.I.V.D.

An Experimental Evaluation on Bond Strength between Porcelain and Recast Allog (도재용(陶材用) 비귀금속(非貴金屬) 합금(合金)의 재사용(再使用)에 따른 결합강도(結合强度)의 실험적(實驗的) 측정(測定))

  • So, Myung-Sub
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.103-109
    • /
    • 1989
  • Bond strength between alloy and ceramic plays an important role in deciding the quaring the processing of metalceramic restorations. Now the author had an experiment on the measurement of bond strength differences accoding to the contents of recast alloy used during the processing of metal-ceramic restorations. In the experiment, Anusavice's Planar Interface Shear Bond Test was employed to determine the bond strength. Total 25 specimens were divided as 5 groups, that is, 5 specimens in a group respections : Group I (new alloy 100%) Group II (new 75%$\cdot$recast 25%), Group III (new 50%$\cdot$recast 50%), Group IV (new 25%$\cdot$recast 75%), Group V(recast 100%). All specimens examined micropically and respective strength values of the group specimens were checked simultaneously. The results were as follows, 1. In the analtsis of variance the result showed the significant differences of 1%(P<0.01) among the each group classifid according to the recast contents. 2. When the interfaces of specimens were examined with an electron microscope, the air bubble were evenly occurred in all the specimens, and the occurrence frequencies and the sizes of air bubble were different between Group I and Group III, especially marked different Group I and Croup V. 3. In respective verification of each group through T-test, between Group I and Group II, between Group I and Group III did not show significant differences. 4. There was significant difference between Group I and Group IV, between Group I and Group V as 1%(P<0.01). 5. In the Shear Bond Test of all the groups, Croup V showed the lowest value. Explanatoion of Figures Fig 1. Main fracture type of metal-porcelain interlace showed in group I, II, III from shear Bond Test resets. Fig 2. Main fracture type of metal-porcelain interface showed In group Ⅳ, Ⅴ form shear Bond Test resets. Air bubble and their size appeared around interface of metal-porcelain. Fig 3. Group I, Fig 4. Group II Fig 5. Group III, Fig 6. Group IV, Fig 7. Group V.

  • PDF

Clinical study on treatment of HIVD of lumbar spine using Scolopendrid herbal acupuncture (오공약침(蜈蚣藥針)을 이용한 요추간판탈출증(腰椎間板脫出症) 치료(治療)의 임상적(臨床的) 연구(硏究))

  • Koh, Kang-Hoon;Park, So-Young;Choi, Hoi-Gang;So, Ki-Sook;Hwang, Wu-Jun;Lee, Kun-Mok;Kim, Sung-Chul
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.192-206
    • /
    • 2002
  • Objective : This study is performed for the purpose of examining into the efficacy of the scolopendrid(Scolopendra morsitans L) which has been used among the Korean people for the H.I.V.D of lumbar spine. Methods & Results : Using the herbal acupuncture made of scolopendrid(Scolopendra morsitans L), we treated the 20 H.I.V.D patients for 1 week and operated 4 pre and post treatment test ; D.I.T.I, 6 kinds of physical test, Oswestry disability index, and self-conscious pain rate. Trough the test, we saw 43-95% of efficacy rate in each test. And all of the 7 acupuncture point in D.I.T.I, Oswestry disability index and self-conscious pain rate test showed statistically valuable change. Conclusion : We brought to the conclusion that the scolopendrid herbal acupuncture has possibility to be efficient to cure the H.I.V.D patients. So we suggest the possibility to use this new remedy for the H.I.V.D.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

A study on the characteristics of deterioration in 6.6kV CV cable (6.6kV CV케이블의 경년열화 특성연구)

  • Kim, K.H.;Sun, J.H.;Kim, Y.B.;Cho, Y.O.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.636-639
    • /
    • 1993
  • This paper is discribed the results of insulation characteristic tests that are DC leakage current, test, tan${\delta}$ test, AC breakdown test and observation of tree in the used 6.6kV CV cables. In the correlation of these tests, the tan${\delta}$ test stands for the main deterioration factor of cable insulation.

  • PDF

Vehicle Communication System Implementation for u-TSN and Its Performance Evaluations (u-TSN에서 차량 통신시스템 구성 및 성능평가)

  • Jeon, Sung-Hee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.7
    • /
    • pp.35-40
    • /
    • 2011
  • In u-TSN environment, the communication between vehicle terminal and roadside equipment is very important to support prompt service and to secure road traffic information in real-time upon organizing traffic system. This study suggested V2I or I2V communication service scenario for performance test on vehicle communication system as well as V2V inter-vehicle communication service scenario for emergency information transmission which requires rapidity and accuracy. After implementing real inter-vehicle communication system, we performed vehicle communication experiment following suggested communication service scenario to test the performance. Consequently, we could draw out the optimal transmission mode setup condition, and the result can be applied to the development of stable and efficient u-TSN vehicle communication system.

Population-Based Newborn Hearing Impairment Screening Test Using GJB2 Mutation Analysis

  • Lee, Kyung-Ok;Jeong, Su-Jin;Byun, Ji-Young;Kim, Jeong-Sook;Lee, Hye-Jung;Seong, Hye-Soon;Kim, Kyung-Tae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.2
    • /
    • pp.113-121
    • /
    • 2007
  • Hearing loss is a common congenital disorder that is frequently associated with mutations in the Cx26 gene (GJB2). Recently, the mutation analysis of GJB2 has been used in a newborn screening test for the detection of hearing impairment. Population-based studies should be performed before the application of genetic testing for the identification of deaf newborns. In this study, 8 positions of GJB2 mutations-including 35delG, 167delT, 235delC, V27I, V37I, M34T, E114G, and I203T-were analyzed using PCR-direct sequencing in a total of 437 healthy Korean neonates. DNAs from dried blood spots were extracted using a commercial DNA extraction kit. The PCR-amplified products (783 bps) of the GJB2 gene were detected using 2% agarose gel electrophoresis and subjected to direct sequencing. The sequences were compared with those in the GenBank database by using the BLAST program. In this study, 5 GJB2 mutations -including V27I (79G>A), V37I (109G>A), E114G (341A>G), I203T (608T>C), and 235delC- were found. Of the 437 neonate samples, 301 subjects showed GJB2 mutations (68.9%, 301/437). The V27I mutation was found in 271 subjects and was the most frequent (62.0%, 271/437). The E114G, I203T and V37I mutations were shown in 146, 17 and 14 subjects, respectively. The 235delC mutation was found in 1 subject. The E114G mutation was frequently accompanied by the V27I mutation. V27I/E114G (97.2%, 143/147) was the most common double mutation and 3 subjects had the double mutation V27I/I203T. A triple mutation, V27I/E114G/I203T, was found in 1 subject. In conclusion, PCR-direct sequencing is a convenient tool for the rapid detection of GJB2 mutations and this data might provide information for the genetic counseling of the GJB2 gene.

  • PDF

Evaluation of Undrained Shear Strength of Busan New-port Clay by DMT (DMT를 이용한 부산신항 점토의 비배수 전단강도 추정)

  • Hong, Sung-Jin;Shin, Dong-Hyun;Kim, Dong-Hee;Jung, Sang-Jin;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.87-98
    • /
    • 2007
  • A series of dilatometer test, field vane test, and $CK_0U$ triaxial test were performed for clayey soils of Busan new port site to develop the relationships between undrained shear strength and the DMT results. Normalized undrained shear strength is turned out to be $S_{u(CKU)}/{\sigma}'_v=0.30{\sim}0.35\;for\;CK_0U$ triaxial test and ${\mu}S_{u(VST)}/{\sigma}'_v=0.20{\sim}0.22$ for vane shear test. By comparing the undrained shear strength estimated from DMT indices with the results measured by in-situ vane test or $CK_0U$ triaxial test, two methods to predict the undrained shear strength from DMT results are suggested. One is based on the relationship between $S_u/{\sigma}'_v$ and horizontal stress index (KD) while another method comes from $N_c-I_D$ and $N_c-E_D$ correlation. It was observed that the method based on $N_c-I_D\;or\;N_c-E_D$ relation shows slightly better accuracy than the one based on $K_D$ although all of the methods suggested in this study provided comparable values of predicted undrained shear strength. Since the definitions of $I_D\;and\;E_D$ contain $p_1-p_0$, in which soil condition is reflected, it is believed that the prediction method using $N_c$ is capable of taking a material type into consideration.

A Study on the Improvement of ZnO Varistor for Distribution Class Surge Arrester(18kV, 5kA) (배전급 피뢰기(18kV, 5kA)용 산화아연바리스타의 성능향상에 관한 연구)

  • Yoo, Deok-Son;Yoon, Han-Soo;Kim, Suk-Soo;Choi, Yeon-Gyu;Jang, Sung-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.744-746
    • /
    • 2003
  • A ZnO varistor with reference voltage 250V/mm was fabricated through the control of particle size in slurry and the variation of sintering conditions. It was found that to measure the flatness of the V-I characteristic curve in the small-current region and the flatness of the V-I characteristic curve in a large-current region was improved nonlinearity of the fabricated ZnO varistor. According to the IEC 60099-4 was measured the accelerated aging test and high current test of the distribution class surge varistor which is excellent in respect to the property of ZnO varistor.

  • PDF