• Title/Summary/Keyword: I-PID

Search Result 170, Processing Time 0.027 seconds

Self-Tuning PID Controller Based on PLC

  • Phonphithak, A.;Pannil, P.;Suesut, T.;Masuchun, R.;Julsereewong, P.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.272-276
    • /
    • 2004
  • The conventional PID (Proportional-Integral-Derivative) control technique is widely used for the process control in many industries since it is simple in structure and provides the good response. Nowadays, this control technique has been developed on the Programmable Logic Controller (PLC) to use for the process control loop. However, using this technique is difficult when tuning the PID parameters ($K_p$, $T_i$ and $T_d$) to achieve the best response. Moreover, trial-and-error procedure along with the operator experiences are required to obtain the best results when tuning the PID controller parameters. This paper proposes the self-tuning PID controller based on PLC for the process control in the industries. The proposed self-tuning PID controller uses the PLC-based PID structures to control the process production. The proposed PID tuning utilizes the PLC to synthesize and analyze controller parameter as well as to tune for appropriate parameters using Dahlin method and extrapolation. Experimental results using a self-tuning PID controller to control temperature of the oven show that the controller developed is capable of controlling the process very effectively and provides a good response.

  • PDF

Performance Comparison of 4-PID Controllers using CDM (CDM을 활용한 4가지 PID제어기의 성능비교)

  • Son, Sang-Gyun;Lee, Hae-Soo;Koo, Choon-Keun;Lee, Sang-Chul;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.682-685
    • /
    • 2000
  • In this paper, Using CDM(Coefficient Diagram Method), we set target polynomial constraints and design 4-PID controller which have different structures such as Textbook PID-controller, Derivative of output PID-controller, set point of I only controller(I-PD controller) and PI controller followed by lag network(PI lag network controller) were tested by simulations. The plant we used are that used in IFAC 93 benchmark test. A controller designer, using CDM could use these results to select the controller's structure which is the best one fer him.

  • PDF

A Design Method For An On-line Adaptive Neural Networks Based Intelligent Controller (온라인 적응 신경회로망을 이용한 지능형 제어기 설계방법)

  • Kim, I.J.;Gu, S.W.;Choi, J.Y.;Choy, I.;Kim, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1341-1343
    • /
    • 1996
  • This paper presents a design method for an on-line adaptive neural networks based intelligent controller. The proposed neural controller, assuming PID controller is initially presented, learns the equivalent behaviors of the existing PID controller initially and switches to take over the PID control system. Then, it executes on-line adaptation via evaluating its performance and minimizing user defined cost function constantly so that the optimal control can be achieved. The PID controller and the proposed neural controller are investigated and compared in computer simulation.

  • PDF

A Study of Improvement on the responsiveness of Digital AVR System (Digital 자동전압조정장치(AVR)의 속응성 향상에 관한 연구)

  • Kim, Song-hyun;Lee, Hyung-ki;Choe, Wook-yeon;An, Young-joo;Kim, Hyun-soo;Kim, Gi-Ryang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.246-247
    • /
    • 2015
  • Type of Automatic Voltage Regulator (AVR) can be divided into Analog and Digital Type. Automatic Voltage Regulator (AVR) of the synchronous generators of the brushless type are to be reduced to the voltage fluctuation on the basis of the total load. The PID control method is a general control technique is commonly widely used. In this study, the control target parameter iPID does not reset the parameters of the controller for the variable (Intelligent PID) using the controller synchronous generator Digital automatic voltage to you like all applied to the adjusting device (AVR) the voltage change is small, improved responsiveness was studied in this controller.

  • PDF

An FPGA-Based Modified Adaptive PID Controller for DC/DC Buck Converters

  • Lv, Ling;Chang, Changyuan;Zhou, Zhiqi;Yuan, Yubo
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.346-355
    • /
    • 2015
  • On the basis of the conventional PID control algorithm, a modified adaptive PID (MA-PID) control algorithm is presented to improve the steady-state and dynamic performance of closed-loop systems. The proposed method has a straightforward structure without excessively increasing the complexity and cost. It can adaptively adjust the values of the control parameters ($K_p$, $K_i$ and $K_d$) by following a new control law. Simulation results show that the line transient response of the MA-PID is better than that of the adaptive digital PID because the differential coefficient $K_d$ is introduced to changes. In addition, experimental results based on a FPGA indicate that the MA-PID control algorithm reduces the recovery time by 62.5% in response to a 1V line transient, 50% in response to a 500mA load transient, and 23.6% in response to a steady-state deviation, when compared with the conventional PID control algorithm.

Design of 2-DOF PID control system by a Neural network (신경망에 의한 2 자유도 PID 제어기의 설계)

  • 허진영;김홍렬;하홍곤;고태언
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.262-266
    • /
    • 1999
  • In this paper, we consider to apply of 2-DOF (Degree of Freedom) PID controller at D.C servo motor system. Many control system use I-PD, PID control system, but the position control system have difficulty in controling variable load and changing parameter. We propose neural network 2-DOF PID control system having feature for removal disturbrances and tracking function in the target value point. The back propagation algorithm of neural network used for tuning the 2-DOF parameter ($\alpha$, $\beta$, ${\gamma}$, η). We investigate the 2-DOF PID control system in the position control system and verify the effectiveness of proposal method through the result of computer simulation.

  • PDF

Load Frequency Control Charateristic of 2-Area Power Systems by Optimal PID Controller (최적PID 제어기에 의한 2지역 전력계통 부하주파수 제어특성에 관한 연구)

  • 정형환;이준탁;안병철;김용필;김해재
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.703-710
    • /
    • 1994
  • This paper describes for the applicability of optimal PID controller to the load frequency control of 2-area power systems. The proposed optimal PID controllers are designed by the optimization technique of P.I.D's gain coefficients using the relatively ingeneous simplex method, and we have considered the system sensitivity for the optimal gains and the stable effects of systems to speed regulation changes. This PID controller for load frequency control systems with exciter shows better performances and robustness than conventional tie-line bias controller.

  • PDF

A Tuning Method for I-PD Controller Using Performance Index (평가함수를 이용한 I-PD콘트롤러의 튜닝)

  • 유항열;이정국;이금원;이준모
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.169-172
    • /
    • 2003
  • PID control has been well used for several decade. For PID algorithm, some tuning methods are used and with these parameters, control system is designed. But in some cases various kinds of performance are needed, so variable type of performance index must be utilized so that the designed control system meets the conditions. This paper presents some linear combinational type of performance index and with numerical methods, the PID parameters are obtained. Moreover I-PD type controller is used so that this two degree of freedom controller may give more desirable output characteristics. Simulations are done with MATLAB m file and mdl files.

  • PDF

Development of 1-axis Exciter for a Seat Vibration Test of Agricultural Tractors(I) - Design of PID Controller for Position Control of 1-axis Exciter - (농용트랙터용 운전자 좌석 진동 시험을 위한 1축 가진 시험기 개발(I) - 1축 가진 시험기 위치 제어를 위한 PID 제어기 설계 -)

  • Yu, Ji-Hoon;Choi, Young-Kyun;Lee, Kyu-Cheol;Kim, Young-Joo;Ryu, Young-Sun;Ryuh, Kwan-Hee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.305-314
    • /
    • 2009
  • The purpose of this paper was to design an effective control system of 1-axis exciter for a seat vibration test of agricultural tractors using MATLAB simulation. The developed simulation model was composed with a hydraulic pump, a hydraulic servo valve, a hydraulic cylinder and load system. Also it was verified by comparing the simulation results with experimental results of actual control system in order to optimize the control performance. And in order to improve its control performance, the designed PID controller in this research was tuned using Ziegler-Nichols 2nd law and zero's moving method of PID controller's transfer function. As the result of these research, the developed position control system was able to control the system's position accurately within 5% errors.

A Study of Moth-eye Nano Structure Embedded Optical Film with Mitigated Output Power Loss in PERC Photovoltaic Modules (PERC 태양전지 모듈의 출력저하 방지를 위한 모스아이(Moth-eye) 광학필름 연구)

  • Oh, Kyoung-suk;Park, Jiwon;Choi, Jin-Young;Chan, Sung-il
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.55-60
    • /
    • 2020
  • The PERC photovoltaic (PV) modules installed in PV power plant are still reports potential-induced degradation (PID) degradation due to high voltage potential differences. This is because Na+ ions in the cover glass of PV modules go through the encapsulant (EVA) and transferred to the surface of solar cells. As positive charges are accumulated at the ARC (SiOx/SiNx) interface where many defects are distributed, shunt-resistance (Rsh) is reduced. As a result, the leakage current is increased, and decrease in solar cell's power output. In this study, to prevent of this phenomenon, a Moth-eye nanostructure was deposited on the rear surface of an optical film using Nano-Imprint Lithography method, and a solar mini-module was constructed by inserting it between the cover glass and the EVA. To analyze the PID phenomenon, a cell-level PID acceleration test based on IEC 62804-1 standard was conducted. Also analyzed power output (Pmax), efficiency, and shunt resistance through Light I-V and Dark I-V. As a result, conventional solar cells were decreased by 6.3% from the initial efficiency of 19.76%, but the improved solar cells with the Moth-eye nanostructured optical film only decreased 0.6%, thereby preventing the PID phenomenon. As of Moth-eye nanostructured optical film, the transmittance was improved by 4%, and the solar module output was improved by 2.5%.