• Title/Summary/Keyword: I/d Parameters

Search Result 873, Processing Time 0.028 seconds

Experimental modal analysis of transverse-cracked rails-influence of the cracks on the real track behavior

  • Domingo, Laura Montalban;Giner, Beatriz Baydal;Martin, Clara Zamorano;Herraiz, Julia I. Real
    • Structural Engineering and Mechanics
    • /
    • v.52 no.5
    • /
    • pp.1019-1032
    • /
    • 2014
  • Rails are key elements in railway superstructure since these elements receive directly the train load transmitted by the wheels. Simultaneously, rails must provide effective stress transference to the rest of the track elements. This track element often deteriorates as a consequence of the vehicle passing or manufacturing imperfections that cause in rail several defects. Among these rail defects, transverse cracks highlights and are considered a severe pathology because they can suddenly trigger the rail failure. This study is focused on UIC-60 rails with transverse cracks. A 3-D FEM model is developed in ANSYS for the flawless rail in which conditions simulating the crack presence are implemented. To account for the inertia loss of the rail as a consequence of the cracking, a reduction of the bending stiffness of the rail is considered. The numerical models have been calibrated using the first four bending vibration modes in terms of frequencies. These vibration frequencies have been obtained using the Experimental Modal Analysis technique, studying the changes in the modal parameters of the rails induced by the crack and comparing the results obtained by the model with experimental results. Finally, the calibrated and validated models for the single rail have been implemented in a complete railway ballasted track FEM model in order to study the static influence of the cracks on the rail deflection caused by a load passing.

The influence of the initial strains of the highly elastic plate on the forced vibration of the hydro-elastic system consisting of this plate, compressible viscous fluid, and rigid wall

  • Akbarov, Surkay D.;Ismailov, Meftun I.;Aliyev, Soltan A.
    • Coupled systems mechanics
    • /
    • v.6 no.4
    • /
    • pp.439-464
    • /
    • 2017
  • The hydro-elastic system consisting of a pre-stretched highly elastic plate, compressible Newtonian viscous fluid, and the rigid wall is considered and it is assumed that on the plate a lineal-located time-harmonic force acts. It is required to investigate the dynamic behavior of this system and determine how the problem parameters and especially the pre-straining of the plate acts on this behavior. The elasticity relations of the plate are described through the harmonic potential and linearized (with respect to perturbations caused by external time-harmonic force) form of these relations is used in the present investigation. The plane-strain state in the plate is considered and the motion of that is described within the scope of the three-dimensional linearized equations of elastic waves in elastic bodies with initial stresses. The motion of the fluid is described by the linearized Navier-Stokes equations and it is considered the plane-parallel flow of this fluid. The Fourier transform with respect to the space coordinate is applied for a solution to the corresponding boundary-value problem. Numerical results on the frequency response of the interface normal stress and normal velocity and the influence of the initial stretching of the plate on this response are presented and discussed. In particular, it is established that the initial stretching of the plate can decrease significantly the absolute values of the aforementioned quantities.

The Experimental Study on Heat Transfer during Melting Process in the Low Temperature Heat Storage System(Ice on Coil Type) (Ice on Coil형 저온 잠열 축열시스템에서의 용융과정시 열전달에 관한 실험적 연구)

  • Kim, Y.K.;Kim, D.C.;Kim, I.G.;Choi, K.K.;Yim, C.S.
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 1999
  • In this study, basic design data which were required for development of highly efficient ice storage system with low temperature latent heat were experimentally obtained. The ice storage system considered in this study was the one that has been widely used in the developed country and called the ice-on-coil type. Using the system, the ice storage performance for various design parameters which were the flow direction and the inlet temperature of the secondary fluid was tested. In addition, the clockwise variation of the heat transfer characteristics of the PCM in the ice storage tank were investigated. During the melting processes in the ice storage tank with several vertical tubes, decrease of the solid-liquid interface area, which was the heat transfer area, between the floating ice and the water made the decreasing rate of IPF less. Also, the total melting energy for the upward flow of the secondary fluid was higher than that for the downward flow during the melting process, but this trend did not appear if the initial temperature of the PCM was $4^{\circ}C$. The average ice recovery efficiency for the upward flow of the secondary fluid was higher than that for the downward flow.

  • PDF

Improvement of Commercial Silicon Solar Cells with N+-P-N+ Structure using Halogenic Oxide Passivation

  • K. Chakrabarty;D. Mangalaraj;Kim, Kyung-Hae;Park, J.H.;J. Yi
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.6
    • /
    • pp.17-20
    • /
    • 2003
  • This paper describes the effect of halogenic gettering during oxide passivation of commercial solar cell with the $N^{+}$-P-$N^{+}$ structure. In order to study the effect of halogenic gettering on $N^{+}$-P-$N^{+}$ structure mono-crystalline silicon solar cell, we performed conventional POCl$_3$ diffusion for emitter formation and oxide passivation in the presence of HCl vapors. The $N^{+}$-P-$N^{+}$ structure based silicon solar cells were found to have higher short circuit current and minority carrier lifetime. Their performance was also found to be superior than the conventional $N^{+}$-P-$N^{+}$ structure based mono-crystalline silicon solar cell. The cell parameters of the $n^{+}$-p-$p^{+}$ and $n^{+}$-p-$n^{+}$ structure based cells, passivated by HCl assisted oxidation were measured. The improvement in $I_{sc}$ was attributed to the effect of the increased diffusion length of minority carriers, which came from the halogenic gettering effect during the growth of passivating oxide. The presence of chlorine caused gettering of the cells by removing the heavy metals, if any. The other advantage of the presence of chlorine was the removal of the diffusion induced (in oxygen environment) stacking faults and line defects from the surfaces of the silicon wafers. All these effects caused the improvement of the minority carrier lifetime, which in-turn helped to improve the quality of the solar cells.

Ductile Fracture Predictions of High Strength Steel (EH36) using Linear and Non-Linear Damage Evolution Models (선형 및 비선형 손상 발전 모델을 이용한 고장력강(EH36)의 연성 파단 예측)

  • Park, Sung-Ju;Park, Byoungjae;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.288-298
    • /
    • 2017
  • A study of the damage evolution laws for ductile materials was carried out to predict the ductile fracture behavior of a marine structural steel (EH36). We conducted proportional and non-proportional stress tests in the experiments. The existing 3-D fracture strain surface was newly calibrated using two fracture parameters: the average stress triaxiality and average normalized load angle taken from the proportional tests. Linear and non-linear damage evolution models were taken into account in this study. A damage exponent of 3.0 for the non-linear damage model was determined based on a simple optimization technique, for which proportional and non-proportional stress tests were simultaneously used. We verified the validity of the three fracture models: the newly calibrated fracture strain model, linear damage evolution model, and non-linear damage evolution model for the tensile tests of the asymmetric notch specimens. Because the stress evolution pattern for the verification tests remained at mode I in terms of the linear elastic fracture mechanics, the three models did not show significant differences in their fracture initiation predictions.

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF

Microbial Decomposition of s-Triazine Herbicides, Atrazine and Simazine by a TNT-degrading Bacterium (TNT-분해세균에 의한 s-Triazine계 제초제인 Atrazine과 Simazine의 미생물학적 분해)

  • 오계헌;이명석;장효원;소재성
    • Korean Journal of Microbiology
    • /
    • v.36 no.3
    • /
    • pp.209-215
    • /
    • 2000
  • The purpose of U7is work was to iilvestigate the degradation of s-h~azine hel-hicidcs, ahilzine and simazine by TNT-degrader under several relevaut physicochemical environ~nental parameters. TNT-degrader showed effective degradability of atrazine and snnazine as well. Both atrazme (GO 1i1~11) and simazine ( 4 5 rng//) were completely degraded within 30 hrs and 4 days of incubation, respectively. As d ~ e concentrations of atrazine and sunazine increased in the media, the degradation ofthose compounds were delayed. Additional caubans were essential to degrade atrazine and simazule, and no degradation was achieved in the absence of additional carbons. The effect of supplemented nitrogens on the degradation of atrazine and sunazine was evalualed. Addition of a suppleinented nitrogen in he growth medium containing ah-azine or siinazine showed partial degr-adation olihose herbicides duriug the incubation period. However, complete degradation of atrazine and simazu~e was examined ul the absence or any supplemented nitrogens. Addltion of yeast extract in this study was inhibilory to atrazine aud siinazine degradations, respectively. TNT-degrader was a small Gram-negative cocco-bacillus. Physiological analysis using BIOLOG sysleln revealed that this strain was Ste~~ol~~opl~orno~~ns rrialtophilia.

  • PDF

Effects of cooling systems on physiological responses and intestinal microflora in early gestating sows exposed to high-temperature stress

  • Jeong, Yongdae;Choi, Yohan;Kim, Doowan;Min, Yejin;Cho, Eunsuk;Kim, Joeun
    • Journal of Animal Science and Technology
    • /
    • v.63 no.4
    • /
    • pp.904-918
    • /
    • 2021
  • This study was conducted to investigate the effect of cooling systems on reproductive performance, body temperature, blood metabolites, and the intestinal microbiome in early gestating sows exposed to high ambient temperature. In total, 39 pregnant sows (Landrace × Yorkshire; 2 parities) were randomly assigned to and maintained in the following three treatment groups (13 sows per group) over days 0 to 35 of pregnancy: (i) air cooling (AC; 26.87 ± 1.23℃), (ii) water-drip cooling (WC; 28.81 ± 0.91℃), and (iii) a lack of cooling with heat stress (HS; 30.72 ± 0.70℃). Backfat thickness was measured before and after HS. Feces were collected on day 0 and 35 d of the trial for microbiome analysis, whereas blood was taken at day 35 of pregnancy and analyzed. Reproductive performance and physiological responses were identified at day 35. Respiration rate along with rectal and skin temperatures were lower (p < 0.05) in the AC group than in the HS and WC groups. Serum blood urea nitrogen values were increased (p < 0.05) in the WC group compared with those measured in the AC and HS groups. Triiodothyronine was found at greater levels (p < 0.05) in the AC than in the HS group. Reproductive performance was not affected by the cooling systems. At the phylum level, fecal pathogenic Spirochaete and Euryarchaeota were found in higher numbers (p < 0.05) in all groups after HS. Similarly, at the genus level, the amount of Treponema was greater (p < 0.05) in all groups after HS. In conclusion, our results suggest that AC or WC can ameliorate or mitigate the adverse effects of HS on the physiological parameters of pregnant sows reared under high temperatures.

Sleep Quality and Attention May Correlate With Hand Grip Strength: FARM Study

  • Lee, Gyuhyun;Baek, Sora;Park, Hee-won;Kang, Eun Kyoung
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.822-832
    • /
    • 2018
  • Objective To determine the socio-demographic, psychologic, hematologic, or other relevant factors associated with hand grip strength in Korean farmers. Methods A total of 528 healthy Korean farmers were enrolled. Hand grip strength was measured in both hands using a hydraulic dynamometer. Socio-demographic characteristics were assessed and anthropometric measurements were obtained. Psycho-cognitive measurements such as sleep quality (Pittsburgh Sleep Quality Index) and Go/No-Go test response time were conducted. In addition to physical measurements, serologic parameters including insulin-like growth factor 1 were measured. The factors associated with hand grip strength were analyzed using multiple linear regression analysis after adjusting for age, height, and weight. Results The mean hand grip strength was associated with the Pittsburgh Sleep Quality Index total score (${\beta}=-0.12$, p=0.01), the Go/No-Go test response time (${\beta}=-0.18$, p=0.001), vitamin D (${\beta}=0.12$, p=0.02), and insulin-like growth factor 1 levels (${\beta}=0.1$, p=0.045). In female farmers, hand grip strength was only associated with the Pittsburgh Sleep Quality Index total score (${\beta}=-0.32$, p<0.001). Conclusion The results of this study demonstrate that hand grip strength was associated with sleep quality and attention in Korean farmers.

The First Report on the Afternoon E-Region Plasma Density Irregularities in Middle Latitude

  • Yang, Tae-Yong;Kwak, Young-Sil;Lee, Jaewook;Park, Jaeheung;Choi, Seonghwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.135-143
    • /
    • 2021
  • We report, for the first time, the afternoon (i.e., from noon to sunset time) observations of the northern mid-latitude E-region field-aligned irregularities (FAIs) made by the very high frequency (VHF) coherent backscatter radar operated continuously since 29 December 2009 at Daejeon (36.18°N, 127.14°E, 26.7°N dip latitude) in South Korea. We present the statistical characteristics of the mid-latitude afternoon E-region FAIs based on the continuous radar observations. Echo signal-to-noise ratio (SNR) of the afternoon E-region FAIs is found to be as high as 35 dB, mostly occurring around 100-135 km altitudes. Most spectral widths of the afternoon echoes are close to zero, indicating that the irregularities during the afternoon time are not related to turbulent plasma motions. The occurrence of afternoon E-regional FAI is observed with significant seasonal variation, with a maximum in summer and a minimum in winter. Furthermore, to investigate the afternoon E-region FAIs-Sporadic E (Es) relationship, the FAIs have also been compared with Es parameters based on observations made from an ionosonde located at Icheon (37.14°N, 127.54°E, 27.7°N dip latitude), which is 100 km north of Daejeon. The virtual height of Es (h'Es) is mainly in the height range of 105 km to 110 km, which is 5 km to 10 km greater than the bottom of the FAI. There is no relationship between the FAI SNR and the highest frequencies (ftEs) (or blanket frequencies (fbEs)). SNR of FAIs, however, is found to be related well with (ftEs-fbEs).