A Study of I/O Serial Communication Systems Between Overground And Overhead Controllers

  • Kim, Duk-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.122-128
    • /
    • 2007
  • This paper represents the Input/Output (I/O) serial communication methods between overground and overhead controllers using a programmable logic controller (PLC). In general, the systems composed by overground and overhead controllers use exclusive serial communication units. This, however, has a demerit such as a high cost as well as some restrictions of the system itself. Thus, this paper suggests methods by I/O cards for data communication between overground and overhead controllers. In this system, there is no special card and it therefore has a lower cost and is more flexible than the exclusive serial communication unit.

Independent I/O Relay Class Design Using Modbus Protocol for Embedded Systems

  • Kim, Ki-Su;Lee, Jong-Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.1-8
    • /
    • 2020
  • Communication between system modules is applied using the Modbus protocol in industrial sites including smart factories, industrial drones, building energy management systems, PLCs, ships, trains, and airplanes. The existing Modbus was used for serial communication, but the recent Modbus protocol is used for TCP/IP communication.The Modbus protocol supports RTU, TCP and ASCII, and implements and uses protocols in embedded systems. However, the transmission I/O devices for RTU, TCP, and ASCII-based protocols may differ. For example, RTU and ASCII communications transmit on a serial-based communication protocol, but in some cases, Ethernet TCP/IP transmission is required. In particular, since the C language (object-oriented) is used in embedded systems, the complexity of source code related to I/O registers increases. In this study, we designed software that can logically separate I/O functions from embedded devices, and designed the execution logic of each instance requiring I/O processing through a delegate class instance with Modbus RTU, TCP, and ASCII protocol generation. We designed and experimented with software that can separate communication I/O processing and logical execution logic for each instance.

Development of Test Equipment for KSLV-I Upper Stage (KSLV-I 상단부 시험장비(UTE) 설계 및 개발)

  • Kim, Kwang-Soo;Lee, Soo-Jin;Chung, Eui-Seung;Park, Jeong-Joo
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.171-179
    • /
    • 2007
  • The Test Equipment for the upper stage of KSLV-I has following functions via umbilical cable interface; external power supply, command output such as discrete and analog, data acquisition, CS-I interface simulation for first stage of KSLV-I and RS-422 serial communication for PDU. The main purpose of UTE is the experiment or function verification of system-level upper stage. To realize this system, we used PXI control system. The UTE is consisted of the PXI control system, power supply, terminal block, internal harness, connector panel and so on. The software functions of UTE are classified by four blocks. These are Discrete/Analog I/O control, PDU RS-422 serial communication control, power supply GPIB control and UTE remote control. In this paper, we will describe the design on the hardware and software of UTE.

  • PDF

Industrial Communication Gateway Design of Communications Module Additive layer type (통신 모듈 적층형 산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Nam, Jae Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.133-136
    • /
    • 2019
  • Recently, many industrial devices are facing protocol compatibility problems with external monitoring and control systems. This paper designed an industrial communication gateway that can support the transformation of industrial communication protocol using multi-layered communication module. Industrial communication gateways have a structure that connects individual communication modules using rs485 serial communication to multiple layers. Each communication module consisted of analog data card, a digital data card LAN, and a CAN-enabled card. The main board processor used Atmega micro-processor, and the rs485 serial slot was placed to have a multi-layer communication module structure. These additive layer type communication modules support analog and digital I/O functions and LAN and CAN for wide use in industrial communication control and monitoring.

  • PDF

A Design of Gateway for Industrial Communication (산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Lee, Byong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.281-283
    • /
    • 2016
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper is prepared in the main control board to support the industrial communication protocol conversion, control, and monitoring. The industrial communication gateway module is also designed to ensure that the protocol conversion of CAN bus and Ethernet. The main board processor is used the Atmega2560, and placed 4ea RS485 serial slots for sub-board. One of them is used for communication CAN bus and Ethernet. It provides analog and digital I / O through each of the slots is used for control and monitoring.

  • PDF

Design and Fabrication of Low Power Sensor Network Platform for Ubiquitous Health Care

  • Lee, Young-Dong;Jeong, Do-Un;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1826-1829
    • /
    • 2005
  • Recent advancement in wireless communications and electronics has enabled the development of low power sensor network. Wireless sensor network are often used in remote monitoring control applications, health care, security and environmental monitoring. Wireless sensor networks are an emerging technology consisting of small, low-power, and low-cost devices that integrate limited computation, sensing, and radio communication capabilities. Sensor network platform for health care has been designed, fabricated and tested. This system consists of an embedded micro-controller, Radio Frequency (RF) transceiver, power management, I/O expansion, and serial communication (RS-232). The hardware platform uses Atmel ATmega128L 8-bit ultra low power RISC processor with 128KB flash memory as the program memory and 4KB SRAM as the data memory. The radio transceiver (Chipcon CC1000) operates in the ISM band at 433MHz or 916MHz with a maximum data rate of 76.8kbps. Also, the indoor radio range is approximately 20-30m. When many sensors have to communicate with the controller, standard communication interfaces such as Serial Peripheral Interface (SPI) or Integrated Circuit ($I^{2}C$) allow sharing a single communication bus. With its low power, the smallest and low cost design, the wireless sensor network system and wireless sensing electronics to collect health-related information of human vitality and main physiological parameters (ECG, Temperature, Perspiration, Blood Pressure and some more vitality parameters, etc.)

  • PDF

Development of the Serial Data Transmission System for Pneumatic Valve System Control

  • Kim, Dong-Soo;Choi, Byung-Oh;Seo, Hyun-Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1152-1156
    • /
    • 2003
  • For pneumatic valve system control, we need a serial data transmission system with high speed and reliability for information interchange between main computer and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic valve system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid control valves. in addition, we developed a communication protocol for construction of rs-485 based multi-drop network and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. the field test results show that, even under high noise environment, the data transmission of 375kbps rate is possible up to 1,500meter without using repeater. In addition, the system developed in this research is easily to be extended for a communication network because of its modular structure.

  • PDF

A Method for Enhancing Data Transmission Performance in the Power-Line Communication Channel with Low-Voltage Surge Protective Devices (저압용 SPD가 설치된 전력선통신에서 데이터전송 성능 향상)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.78-85
    • /
    • 2012
  • Low-Voltage power lines should equip surge protection devices which protect electronic equipments and human lives against lightning and abnormal voltages. Data transmission capacity of the power line is determined by frequency characteristics of the surge protective devices. To analyze the effects of surge protective devices on the data transmission performance, various combinations of installation methods are tested which include ZnO varistor elements that is compatible with class I, class II and class III. The result claims that ZnO varistor for class III is found to be one of the main factors that deteriorates the transmission performance. To overcome this problem a serial connection methed between Gap type SPD and ZnO varistor is proposed. With the proposed scheme, laboratory experimental results show that the data transmission performance can be improved up to 91.9[%] with proper SPD combination.

An Industrial monitoring board design with support for multiple communications (다양한 통신을 지원하는 산업용 모니터링 보드 설계)

  • Eum, Sang-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.197-199
    • /
    • 2018
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper is prepared in the main control board to support the industrial communication protocol conversion, control, and monitoring. The industrial communication gateway module is also designed to ensure that the protocol conversion of CAN bus and Ethernet. The main board processor is used the Atmega2560, and placed 4ea RS485 serial slots for sub-board. One of them is used for communication CAN bus and Ethernet. It provides analog and digital I / O through each of the slots is used for control and monitoring.

  • PDF

Design of Phone Card IC with Security and Self-test Features (자체 테스트 및 보안기능을 갖는 공중전화 카드 IC 설계)

  • Park, Tae-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.60-66
    • /
    • 2000
  • This paper proposes a design of phone card IC with the self-test features and the hardware and software security functions. We design and verify the proposed functions with modeling the terminal system environment. The proposed phone card IC provides instructions and a non-volatile memory block containing the manufacturer / issuer / user information, the unit (money) value, and the security key. The self-test functions are designed to improve the test time degradation due to a serial I/O communication. Also some security features are implemented using hardware and software approaches.

  • PDF