• Title/Summary/Keyword: Hypochlorous

Search Result 46, Processing Time 0.027 seconds

Analysis of Chlorine Species in Chlorine Dioxide Bleaching Liquor and Generation Process by UV-VIS Spectroscopy

  • Wang, Li-Jun;Lee, Seon-Ho;Yoon, Byung-Ho
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04a
    • /
    • pp.78-83
    • /
    • 1999
  • In this paper the extinction coefficients of molecule chlorine ($Cl_2$), chlorine dioxide (ClO$_2$), hypochlorous acid (HClO), chlorous acid ($HClO_2$$_2$) were determined using a PDA UV-VIS spectrophotometer. Based on these, the concentrations of $Cl_2$, $ClO_2$, and HClO in general chlorine dioxide bleaching liquor can be measured. The concentrations of $Cl_2$, $ClO_2$ and $HClO_2$ produced during the generation of methanol based chlorine dioxide generator can also be determined use the same method. The method was thought to be able to give more information in chlorine dioxide bleaching chemistry if combine its use with titration and ion chromatography.

  • PDF

Generation and Characteristics Analysis of Swine Manure for Introducing Biogas System (논문 - 바이오가스화 도입을 위한 양돈농가 가축분뇨 발생 및 특성분석)

  • Choi, Eun-Hee;Yoon, Young-Man;Kim, Chang-Hyun
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.25-32
    • /
    • 2011
  • The 21 livestock farms considering future installation of biogas systems were studied. These farms were examined how to raise the livestock, to treat manure, to operate facility with respect to manure characteristics. The 15 farms out of 21 farms have applied to the marine dumping and consignment treatment for treating manure and even farms which have equipped liquid fertilizing system have less capacity facility than legal standards. Characteristics of manure were affected by the scale of swine barn, clean water usage, frequency of cleaning, cleaning method, feces-urine separating method, etc. Retention time in storage (over 20 days) has resulted in lower concentration of organic matter which could reduce biogas production. This indicates that systematic barn management system is required. Inhibition tests showed that disinfectant and citric acid did not affected digestion rates at 10 times higher concentration than recommendation. However hypochlorous acid is likely to affect the anaerobic microbial activity.

  • PDF

Model development for chlorine generation using electrolysis (전기분해에 의한 잔류염소 생성 예측 모델 개발)

  • Sohn, Jinsik;Lee, Sunjae;Shin, Chorong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.331-337
    • /
    • 2009
  • Electrolysis produces hypochlorous acid by using a small quantity of NaCl as electrolyte. This process maximizes the stabilization of drinking water through the control of chlorine residual concentration. This study investigated free chlorine generation by an electrolytic method using $Ti/IrO_2$ and stainless steel. The generation of free chlorine was increased with increasing hydraulic retention time, voltage, chlorine ion concentration and the number of electrodes. However, the change of pH did not affect the generation of free chlorine. There was no significant difference on the behavior of chlorine concentration between electrolytic method and NaOCl injection. In this study, the concentration of free chlorine predicted model based on power functional model was developed various under conditions. Electrolysis free chlorine generation model can be effective tool in the estimation of free chlorine generation.

Comparison of Spectrophotometric, HPLC and Chemilumines­cence Methods for 3-Nitrotyrosine and Peroxynitrite Interaction

  • Turan Nilufer Nermin;Ark Mustafa;Demiryurek Abdullah Tuncay
    • Archives of Pharmacal Research
    • /
    • v.28 no.3
    • /
    • pp.358-363
    • /
    • 2005
  • We have studied the interaction of 3-nitrotyrosine with peroxynitrite using three different methods; chemiluminescence, spectrophotometry and HPLC. Peroxynitrite-induced luminol or lucigenin chemiluminescence were significantly decreased by 3-nitrotyrosine, in concentration­dependent manners. The intensity of the peroxynitrite spectrum was also markedly reduced in the presence of 3-nitrotyrosine in the spectrophometric assay. However, there was no attenuation of the 3-nitrotyrosine signal in the HPLC assay after mixing with peroxynitrite. The interaction of 3-nitrotyrosine and hypochlorous acid (HOCI) was also studied via the chemilumines-cence assay, where the HOCI-induced responses were markedly inhibited by 3-nitrotyrosine. These results suggest that caution should be taken when studying the levels or interactions of 3-nitrotyrosine.

Role of Electrode Reaction of Electrolyte in Electrokinetic-Fenton Process for Phenanthrene Removal (동전기-펜턴 공정에서 전해질의 전극반응이 처리효율에 미치는 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • The effects of electrolytes were investigated on the removal efficiency when several different electrolytes were used to change the electrode reaction in an electrokinetic (EK)-Fenton process to remediate phenanthrene-contaminated soil. Electrical potential gradient decreased initially due to the ion entrance into soil and then increased due to the ion extraction from soil under the electric field. Accumulated electroosmotic flow was $NaCl>KH_2PO_4>MgSO_4$ at the same concentration because the ionic strength of $MgSO_4$ was the highest and $Mg(OH)_2$ formed near the cathode reservoir plugged up soil pore to inhibit water flow. When hydrogen peroxide was contained in electrolyte solution, removal efficiency increased by Fenton reaction. When NaCl was used as an electrolyte compound, chlorine ($Cl_2$) was generated at the anode and dissolved to form hypochlorous acid (HClO), which increased phenanthrene removal. Therefore, the electrode reaction of electrolyte in the anode reservoir as well as its transport into soil should be considered to improve removal efficiency of EK-Fenton process.

Enhanced Antibacterial Activity of Sodium Hypochlorite under Acidic pH Condition (산성 pH 조건에서 차아염소산나트륨의 항균 활성 향상)

  • Son, Hyeon-Bin;Bae, Won-Bin;Jhee, Kwang-Hwan
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.2
    • /
    • pp.211-217
    • /
    • 2022
  • Sodium hypochlorite (NaClO) is a disinfectant widely used in hospitals and food industries because of its antimicrobial activity against not only bacteria but also fungi and virus. The antibacterial activity of NaClO lies in the maintenance of a stable hypochlorous acid (HClO) concentration, which is regulated by pH of the solution. HClO can easily penetrate bacterial cell membrane due to its chemical neutrality and the antibacterial activity of NaClO is thought to depend on the concentration of HClO in solution rather than hypochlorite ions (ClO-). In this study, we investigated the antibacterial activity of NaClO according to pH adjustment by means of time kill test and assays of Reactive Oxygen Species (ROS) and adenosine triphosphate (ATP) concentration changes before and after NaClO treatment. We also investigated that the degree of cell wall destruction through field emission scanning electron microscopy (FE-SEM). Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) exposed to 5 ppm NaClO at pH 5 exhibited 99.9% mortality. ROS production at pH 5 was 48% higher than that produced at pH 7. In addition, the ATP concentration in E. coli and S. aureus exposed to pH 5 decreased by 94% and 91%, respectively. As a result of FE-SEM, it was confirmed that the cell wall was destroyed in the bacteria by exposing to pH 5 NaClO. Taken together, our results indicate that the antibacterial activity of 5 ppm NaClO can be improved simply by adjusting the pH.

Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement (잔류염소 측정용 전기화학센서의 유효성)

  • Kim, Hong-Won;Chung, Nam-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

Developing numerical method to predict the removal of Microcystin-LR in a clear well

  • Yeo, Inhee;Park, Yong-Gyun;Kim, Dooil
    • Membrane and Water Treatment
    • /
    • v.9 no.3
    • /
    • pp.173-179
    • /
    • 2018
  • Microcystin-LR, one of algal toxins induced by the eutrophication of a reservoir, is known to be harmful to human by adversely affecting our liver and brain. Hypochlorous acid is very efficient to remove Microcystin-LR in a clear well. The previous researches showed that CT, pH and temperature affected removal rate in batch tests. It was noted that hydrodynamic properties of clear well could also influence its removal rate. A mathematical model was built using an axial dispersion reactor model and software was used to simulate the removal rate. The model consisted of the second order differential equations including dispersion, convection, Microcystin-LR reaction with chlorine. Kinetic constants were obtained through batch tests with chlorine. They were $0.430{\times}10^{-3}L/mg/sec$ and $0.143{\times}10^{-3}L/mg/sec$ for pH 7.0 and 8.1, respectively. The axial dispersion reactor model was shown to be useful for the numerical model through conservative tracer tests. The numerical model successfully estimated the removal rate of Microcyctin-LR in a clear well. Numerical simulations showed that a small dispersion number, low pH and long hydraulic retention time were critical for higher removal rate with same chlorine dosage. This model could be used to optimize the operation of a clear well during an eutrophication season.

Inactivation of Bacteriophage f2 with Chlorine (염소에 의한 bacteriophage f2의 살균작용)

  • Chi Kyung KIM;Kyung Hee MIN
    • Korean Journal of Microbiology
    • /
    • v.16 no.2
    • /
    • pp.62-70
    • /
    • 1978
  • Chlorine was used for inactivation of bacteriophage f2 at pH 5.5, 7.5, and 10.0 at $10^{\circ}C$. The inactivation rate phage with chlorine varied depending on the pH value and reaction time. Hypochlorous acid appeared to be the major species of free chlorine for the inactivation. Suevival of the phage treated with chlorine and infectivity of the RNA extracted from the chlorinated phage were examined. The RNA extracted from untreatd phage was chlorinated and its infectivity was assayed. All three samples showed similar rates of inactivation at pH 5.5 and 7.5, but the naked RNA was more susceptible to chlorine at pH 10.0. The rate of inactivation was compared naked RNA was more susceptible to chlorine at pH 10.0. The rate of inactivation was compared with specific and non-specific attachment of the phasge f2. The specific attachment of the phage increased after the phage had been inactivated by extended chlorination. Chlorine may penetrate to the becteriophage f2 by altering the structural integrity of the protein coat, but the main target of free chlorine for inactivation of the phage appeared to be the phage RNA.

  • PDF

The Study of Characteristics of Electrolytic Water (전해수의 특성에 관한 연구)

  • Lee, Chan-Woo;Bae, Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.18 no.6 s.91
    • /
    • pp.43-48
    • /
    • 2006
  • Electrolytic water(EW), studied in recent decades in the Japan, Russia and United State of America, have shown promise as a method of disinfection whereby low levels of free chlorine, sodium hypochlorite, or hypochlorous acid may be produced in situ in Nacl-containing solution. These methods have shown promise in destruction of microorganisms in medical, dental environment, and in the agriculture and food industry. A recently EW treatment system was evaluated for reducing scouring agent and other surfactants in the washing and scouring process of textile industry Unfortunately, there is, to my knowledge, no serious studies of the properties of EW for textile industry In order to study the characteristics of EW and confirm the possibility of applications in textile industry processes, the pH, surface activity, penetration force, surface tension, and contact angle of EW was measured under various conditions. In general terms, What all this shows is that there is fundamental difference between the properties of EW and that of distilled water.