• 제목/요약/키워드: Hydrothermal heat pump

검색결과 106건 처리시간 0.017초

건축물 용도별 내부 발열부하에 따른 수열원, 지열원 및 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 (Comparative Analysis of Energy Performance of Hydrothermal, Geothermal Source and Hybrid Heat Pump System According to Internal Heat Load for Office, School and Smart Farm)

  • 박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, comparative analysis of energy performance in Taebaek city, a test area, by applying hydrothermal, geothermal source and hybrid heat pump system to office, school and smart farms with different internal heat loads. The conclusion is as follows. In the load characteristics by use of buildings, it was found that office had a large cooling load compared to heating load, school had a large heating load compared to cooling load, and smart farm had only cooling load year-round. Performance analysis of the heat pump system in office shows that the cooling COP of the hydrothermal source is 5.12% and the heating COP is 3.22% lower based on the geothermal source, the cooling COP of the hybrid is 0.41% higher, and the heating COP is the difference in performance appeared sparsely. The performance analysis of the heat pump system in school showed that the cooling COP of the hydrothermal source was 10.44% and the heating COP 3.22% lower based on the geothermal source, and the performance difference between the hybrid cooling and heating COP was insignificant. Heat pump system performance analysis in smart farm only occurred with cooling load. Based on geothermal sources, the cooling COP of the hydrothermal source was 46% and the cooling COP of the hybrid was 19.65%, respectively.

복합열원 히트펌프 최적 제어를 위한 열원에 따른 히트펌프 성능 및 에너지 소요량 패턴 비교 (Comparison of Heat Pump Performance and Energy Consumption Patterns according to Heat Sources for Optimal Control of Multi-Source Heat Pumps)

  • 고유진;박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.31-38
    • /
    • 2020
  • The investment in the technology of using a combined heat source is insufficient, which utilizes the advantages of various heat sources to maximize the potential energy and at the same time increases the performance of the heat pump. In this study, as basic data for the development of a high-efficiency hybrid heat pump system that actively connects and uses various heat sources, simulations were conducted for the heat pumps in two cases where geothermal and hydrothermal heat were applied respectively. In May, COP increased by about 27.3% compared to geothermal heat. In February, the COP percentage decrease of hydrothermal heat compared to geothermal heat is -6.9%. In May, total energy consumption can be reduced by 21.1% when hydrothermal is applied compared to geothermal heat. In February, the total energy consumption increases by 3.4%.

2단 압축 수열원 열펌프 시스템의 부분부하 운전특성에 관한 연구 (A study on the part-load performance of 2-stage water source heat pump)

  • 이영수;백영진
    • 한국지열·수열에너지학회논문집
    • /
    • 제5권1호
    • /
    • pp.13-17
    • /
    • 2009
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. In this study, an experimental study on a 2-stage heat pump, which is designed to utilize a river water heat source, were carried out. Generally, a heat pump is designed for maximum capacity rate, but it actually operates at part load condition in most cases. Therefore, an information on the part-load characteristic is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes.

  • PDF

지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구 (A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System)

  • 강신형;이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

공기, 지열 및 복합 열원 열펌프의 중간기 에너지 소비량에 관한 연구 (Study on Energy Consumption of Air-source, Ground-source and Dual-source Heat Pump during Intermediate Season)

  • 조영욱;우태호;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.1-7
    • /
    • 2013
  • This study is to compare energy consumption of air-source, ground-source and dual-source heat pump systems during intermediate season using dynamic simulation. Ground-source heat pump has higher COP than that of air-source but requires additional power consumption of auxiliary equipment such as circulation pump. During intermediate season when the outdoor air temperature is favorable, total COP of air-source heat pump may be greater than that of ground-source when circulation pump power consumption is included. Dual-source heat pump which selects the more favorable heat source is compared with air-source only and ground-source only heat pumps for total power consumption. Results show that power consumption of dual-source heat pump is lower than that of ground-source only by 0.73%.

열펌프 열량계 구조 및 성능 특성 연구 (The Study on the Structure and Performance of Heat Pump Calorimeter)

  • 박승병;이상혁;최진일;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.7-13
    • /
    • 2015
  • The efficiency, reliability and performance of any heat pump unit can only be ascertained after it has been tested and rated. For this reason, specific facilities, equiped with testing plants are built. Heat pump calorimeter is the facilities used by most of these testing facilities in their rating and certification process. The ultimate function of calorimeters is to, control and maintain the constant standard test conditions (indoor/outdoor entering temperatures and flow rate etc) during testing period. In this study, the test standards of heat pump unit and the structure of the calorimeter are surveyed. In addition, this study analyzes the total energy consumption of a water to water heat pump calorimeter. Heat pump calorimeter consumed much energy to excute the heat pump tests. The energy consumption of the calorimeter was higher than the heat pump unit, and it was increased as the heat pump unit capacity decreased.

열교환방식에 따른 지열히트펌프의 난방특성에 관한 연구 (A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods)

  • 차동안;권오경;박차식
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2012
  • The objective of this study is to investigate the influence on the heating performance for a water-to-water 10RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The heating capacity and COP of the heat pump increased with increasing ground heat source temperature. As a result, compared to a refrigerant switching method, the water switching method with counter flow improves the heating capacity and COP by approximately 5% in average, respectively.

지열원 히트펌프 유닛 인증 현황 및 성능 분석에 관한 연구 (A Study on the Certified Ground Source Heat Pump and Performance Analysis)

  • 양찬우;강희정;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.22-32
    • /
    • 2022
  • To reduce energy consumption and CO2 emission in building sector, a ground source heat pump system has been highly adopted due to its high efficient by many regulation. A certification system has been operated to distribute reliable and high-efficient heat pump units. In this study, the performance status of the recently certified ground source heat pump unit with components was investigated. All heat pump units certified from 2015 to 2020 were water to water heat pump types. Compared to the past, higher capacity systems over 400 kW have been certificed. The cooling COP of the heat pump unit based on certification criteria showed higher value than the heating COP. It is highly recommended to revise the certified criteria values considering operating conditions individually. Most of ground source heat pump units have employed scroll type compressors and plate type heat exchangers with HFC refrigerant.

하이브리드 지중열교환기 적용 지열 히트펌프 시스템의 난방 성능 분석 (Heating Performance Analysis of Ground-Source Heat Pump (GSHP) System using Hybrid Ground Heat Exchanger (HGHE))

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.8-16
    • /
    • 2020
  • This paper presents the heating performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a surface water heat exchanger (SWHE) and a vertical GHE. In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the HGHE. During the entire measurement period, the average heating capacity of the heat pump was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the HGHE used 6.7 kW of power. Therefore, the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the HGHE.

열원에 따른 열펌프의 성능 비교 및 경제성 평가 (Performance Characteristics and Economic Assessment of Heat Pump Systems with the Various Heat Source)

  • 박차식;박경우;권오경
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2011
  • The objectives of this study are to analyze the performance of a heat pump system with the various heat source and to carry out economic assessment for the heat pump system. The COP of the river water and ground source heat pump system was 20% higher than that of the air source heat pump system because river water and geothermal provide stable operating temperature compared with air temperature throughout the year. In addition, the economic assessment of a heat pump system using air, river water, and geothermal as a heat source was carried out. The ratio of the life cycle operating cost to the life cycle cost increased with the increase of building capacity. The payback period was found to be less than 3.3 and 4.5 years, respectively when the capacity of the river water and ground source heat pump was larger than 10 RT.