Finite Element Analysis and Evaluation of Casting Defects of Steam Turbine Valve Casings of Power Plants (발전용 증기터빈 밸브 케이싱의 유한요소해석과 주조결함 평가 방법)

  • Lee Boo-Youn;Kim Won-Jin;Shin Hyun-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.571-578
    • /
    • 2005
  • Stresses of main stop valve and control valve casings for the steam turbines of power plants are analyzed by the finite element method. The stress intensity is obtained to check the results on the basis of the design criteria of ASME boiler and pressure vessel code. To verify accuracy of the finite element analysis. analyzed stresses are compared with those measured during the hydrostatic pressure test. Stress category drawings. which play an important role in evaluating casting defects, are produced from the analysis results, and important points in casting of the valve casings are discussed in terms of the stress category.

An Aanalytical Study of Structural Performance Evaluation for Multi-stage Control Movable Weir (다단제어 가동보의 구조성능 평가를 위한 해석적 연구)

  • Lee, Haesoo;Park, Taehyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.5
    • /
    • pp.61-68
    • /
    • 2021
  • Movable weirs with multi-stage control are necessary in many Korean rivers to actively control the water storage level. A mesh dependency test was performed to determine the appropriate number of meshes for structural analysis of movable weirs. The standing angles of movable weirs were set to 60°, 45°, 30°, and 15° for stress analysis. The standing angle of 0° was excluded from the analysis because it was unloaded. Changes in the standing angle led to changes in the water depth, maximum pressure, maximum strain, and maximum stress. The maximum average stress and the structural safety of the multi-stage control movable weir were computed and tested using the Ansys FEA software package.

Experimental Study on Compressibility Modulus of Pressure Compensation Oil for Underwater Vehicle (심해 장비용 압력보상유의 압축성 계수 측정을 위한 실험적 연구)

  • Kim, Jin-Ho;Yoon, Suk-Min;Hong, Sup;Min, Cheon-Hong;Sung, Ki-Young;Yeu, Tae-Kyeong;Choi, Hyuek-Jin;Lee, Seung-Guk
    • Ocean and Polar Research
    • /
    • v.37 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • In order to determine the appropriate volume of the a pressure compensator of deep seabed mining robots, this paper reports on an experimental test for oil volume change in an oil-filled box. At the design stage of underwater robots, it is crucial to determine the capacity of the hydraulic compensator which is replenished as much as the contracted oil volume of the robots. A pilot mining robot, MienRo was designed to work under 6,000 m in the deep sea. The hydraulic actuating oil and pressure compensating oil of MineRo may be exposed at a hydrostatic pressure environment of 600 bar. Although the oil can be assumed to be incompressible, its volume is actually changed under high pressure conditions due to air contained in the oil and oil contraction. To determine the capacity of the pressure compensator, the oil contraction rate should be verified through an experimental test using a hyperbaric chamber.

The Experimental Study of Insulation Structure for BOG Re-liquefaction Drum (증발가스 재액화 드럼의 단열구조에 관한 실험적 연구)

  • Kim, Ik-Soo;Jung, Young-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • The re-liquefaction drum is a product that installed spray nozzles at the top to directly spray overcooled LNG into evaporative gas and installed demistors to facilitate gas separation, which was developed to increase the re-liquidity efficiency of small scale re-liquefaction facilities. In the hydrostatic test of the drum, no leakage occurred even at a pressure of 1.5 times the design pressure, but during the BOR(Boil Off Rate) test, the bolt loosening occurred due to contraction and expansion by temperature change. For the continued use of the product, insulation construction on flange connections was developed to enable detachment and attachment, and the comparison of heat load with existing insulation confirmed that it was very small compared to the inlet flow rate in the drum.

Evaluation Method of Plastic Pipe for High-Strength Water Supply (고강도 수도용 PVC관의 성능평가 연구)

  • Park, Jong-II;Lee, Chang Suck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • High-strength plastic water supply pipe evaluation method was evaluated in this study. Up to date, high strength water supply pipes that we install are mostly ductile cast iron pipes. Sometimes, a few PVC pipes are installed. Metal pipes have rust problem on the surface, causing serious damage to metal pipes and reducing the expected life span of water piping system. Nowadays, depending on technology development, some companies have improved properties of general PVC pipe performance with remarkable properties that exceed KS and ASTM standard. Here, we suggest a new method of performance evaluation for high-strength water plastic pipes.

Finite Element Analysis of Axisymmetric Sheet Hydroforming Processes (축대칭 박판 액압성형 공정의 유한요소 해석)

  • Jeong, Y. H.;Lee, S. H.;Keum, Y. T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.26-29
    • /
    • 1999
  • The sectional forming analysis program for analyzing the hydroforming processes of axisymmetric sheet parts was tleveloped. The rigid-viscoplastic FEM formulation based on membrane theory was derived, wh~cta simi~ltaneously solve force equilibrium as well as non-penetration condition. Hill's non-quadratic normal anisotropic yield theory(1979) was used for material behaviour. For describing the liquid pressure iaction, the flexible tool concept was introduced. Isotropic hardening law was also assumed. To verify the \,alidity of the formulation, the stepped cup forming process as well as the hydrostatic bulging test were \imnlated. Simulation results agreed well with Finckenstein and experimental ones.

  • PDF

Effect of Confining Pressure, Temperature, and Porosity on Permeability of Daejeon Granite: Experimental Study (대전 화강암의 투수계수에 미치는 구속압, 온도, 공극률의 영향: 실험적 연구)

  • Donggil Lee;Seokwon Jeon
    • Tunnel and Underground Space
    • /
    • v.34 no.1
    • /
    • pp.71-87
    • /
    • 2024
  • In deep geological disposal of high-level radioactive waste, the surrounding rock at the immediate vicinity of the deposition hole may experience localized changes in permeability due to in-situ stress at depth, swelling pressure from resaturated bentonite buffer, and the heat generated from the decay of radioactive isotopes. In this study, experimental data on changes in permeability of granite, a promising candidate rock type in South Korea, were obtained by applying various confining pressures and temperature conditions expected in the actual disposal environment. By conducting the permeability test on KURT granite specimens under three or more hydrostatic pressure conditions, the relation in which the permeability decreases exponentially as the confining pressure increases was derived. The temperature-induced changes in permeability were found to be negligible at temperatures below the expected maximum of 90℃. In addition, by establishing a relation in which the initial permeability is proportional to the power of the initial porosity, it was possible to estimate permeability value for granite with a specific porosity under a certain confining pressure.

Circulatory and Respiratory Responses to Postural Changes (체위 변화에 수반되는 순환 및 호흡반응)

  • Chae, E-Up;Lee, Suck-Kang;Bae, Sung-Ho
    • The Korean Journal of Physiology
    • /
    • v.7 no.1
    • /
    • pp.13-21
    • /
    • 1973
  • An attempt was made to study circulatory and respiratory responses to the passive tilt. Anesthetized dogs were tilted from horizontal to upright $(+90^{\circ})$ and head down $(-90^{\circ})$ position. The arterial blood pressure was decreased in the upright position and was decreased slightly in the head down position comparing to that in the horizontal position. Cardiac index also decreased in the both upright and head down positions. The total systemic vascular resistance was slightly increased in the upright position and was markedly increased in the head down position. The mean pulmonary arterial pressure was significantly decreased in the both upright and head down positions. The total pulmonary vascular resistance was decreased in the both upright and head down positions. Oxygen consumption was slightly decreased in the upright position, whereas it was slightly increased in the head down position. The A-V $O_2$ difference (vol. %) was slightly increased in the upright position and increased in the head down position. From the above results, process of the circulatory compensation to the gravity in the Passive tilting test was discussed. Neuronal cardiovascular regulation to the gravity and tile adaptation of capacitance vessles to hydrostatic stress and oxygen consumption concerning anoxic endurance of the brain were also discussed.

  • PDF

Behavior of Geotextile Tube by Numerical Analysis (수치해석기법을 이용한 지오텍스타일 튜브의 거동분석)

  • 신은철;오영인;조인휘
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.385-392
    • /
    • 2003
  • Traditional forms of river and coastal structures have become very expensive to build and maintain, because of the shortage of natural rock. Geotextile tubes hydraulically or mechanically filled with dredged materials have been applied in hydraulic and coastal engineering in recent years(shore protection structure, detached breakwater, groins and jetty). Recently, new preliminary design criteria supported by model and prototype tests, and some stability analysis calculations have been studied. In this study, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of geotextile and hydraulic pumping conditions. Numerical analysis was executed to compare with the results from the large-scale field model tests, and also compared the results of 2-D plane strain analysis and 3-D FEM analysis. A geotextile tube was modeled using the commercial finite element analysis program ABAQUS and the one-quarter of tube was modeled. Behavior of geotextile tube during the hydraulic pumping procedure was analyzed by comparing the large-scale field model test and numerical analysis. The shape variation and maximum tube height between the numerical analysis results and large-scale filed test results are turned out to be a good agreement.

  • PDF

Constructability of a Waterproofing Sheet Joint Combining an Aluminum Thin-film and Viscosity Layer Using a High-frequency Inductive Heating Apparatus (고주파 유도가열 장치를 이용한 알루미늄 박판 점착 복합방수시트 조인트부의 시공성)

  • Chang, Sang Mook;Kim, Yun Ho;Choi, Sung Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Engineers in the construction field have been using bonded waterproofing sheets in an attempt to resolve the imbalance in the quality, the risk of fire, safety of workers, and environmental pollution, as well as to eliminate separate use of organic adhesives on the surface of concrete. Recently, self-laminated waterproofing sheets have been developed. The purpose of this research is to find an appropriate processing speed according to the changes in physical properties, and visual observation of the waterproofing sheets laminated by the aluminum thin-film and viscosity layer that can be attached through self-adhesiveness on the surface of concrete and waterproofing sheets. Therefore, this research is conducted using a physical performance test. Based on the result of the test, when the high-frequency inductive heating apparatus was used, an improved adhesion and bonding stability effect were confirmed after the anti-hydrostatic pressure and bond strength in the temperature condition, and the surface observation in the processing speed condition.