• 제목/요약/키워드: Hydrogen-Oxygen Gas

검색결과 408건 처리시간 0.025초

수소-산소 혼합가스의 열절단 특성 연구 (A Study on thermal cutting characteristics of hydrogen-oxygen mixed gas)

  • 김남인;장용원;정준식;이정수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.8-10
    • /
    • 2007
  • In recent years, hydrogen-oxygen mixed gas generated by electrically dissociating water has been proposed as alternative cutting fuel. The mixed gas consists of a hydrogen-oxygen mixed gas in the mixture ratio of 2:1. And gas has some merits as cutting quality and speed compared with existing gas cutting process. Because main source of mixed gas is water, mixed gas is environmental-friendly clean fuel. The purpose of the present paper is to investigate cutting characteristics and optimum cutting parameters of mixed gas, The effect of cutting parameter on the cutting characteristics of mixed gas is also investigated as compared to existing gas cutting process.

  • PDF

Mixed Hydrogen Gas Generator용 전력변환장치 개발 (Development of Mixed Hydrogen Gas Generator Power Conversion System)

  • 정장근;문상필;조길제;김창일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.88-92
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using IGBT converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input power, it has acquired higher input power per Gas quantities at put pulse curren. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

A Study on V-I Characteristics of Hydrogen-Oxygen Gas Generator

  • Yang Seung-Heun;Kang Byoung-Hee;Gho Jae-Soek;Mok Hyung-Soo;Choe Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.109-112
    • /
    • 2001
  • Water-Electrolyzed gas is a mixed gas of the constant volume ratio 2:1 of Hydrogen and Oxygen gained from electrolyzed water, and it has better characteristics in the field of economy, efficiency of energy, and environmental intimacy than acetylene gas and LPG (Liquefied Petroleum Gas) used for existing gas welding equipment. So studies of Water-Electrolyzed gas are activity in progress nowaday, and commercially used as a source of thermal energy for gas welding in the industry. The object of this paper is getting a V-I characteristic of Hydrogen-Oxygen Gas Generator using DC source. First, chemical analysis of electrolysis is conducted and the relation of electrical energy and then chemical energy is investigated through the faraday's laws.

  • PDF

수산화가스 발생기의 V-I 특성에 관한 연구 (A Study on V-I feature of Hydrogen-Oxygen Gas Generator)

  • 양숭헌;김경현;강병희;목형수;최규하;이승학
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.312-315
    • /
    • 2001
  • Water-Electrolyzed gas is a mixed gas of the constant volume ratio 2:1 Hydrogen and Oxygen gained from electrolyzed water, and it has better characteristics in the field of economy, efficiency of energy, and environmental intimacy than acetylene gas and LPG used for existing gas welding equipment. So studies of Water-Electrolyzed gas are activity in progress nowadays, and commercially used as a source of thermal energy for gas welding in the industry. The object of this paper is V-I feature of Hydrogen -Oxygen Gas Generator using DC source

  • PDF

고체고분자전해질 계면에 접한 수소 산소 혼합 가스의 전압전류 특성 (Voltage-Current Profiles of Hydrogen-Oxygen Mixture Gas at Polymer Electrolyte Interface)

  • 차석렬;송정민;이웅무
    • 한국수소및신에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.129-135
    • /
    • 1996
  • 전해질로써 $Nafion^{(R)}$과 같은 고체고분자막과 수소/산소 가스가 계면을 형성할 경우의 전압전류특성을 측정하였다. 사용된 가스는 수소와 산소의 조성비를 달리하여 혼합한후 공급하였다. 사용된 전극은 상업용 탄소 기체 확산 전극을 이용하였으며 전극의 분산된 촉매와 전해질과의 접촉을 용이하게 하기위해 5% $Nafion^{(R)}$을 발라주었다. 직류전원 공급장치를 이용하여 산화 전극과 환원 전극에 걸어주는 전압을 조정하였다. 전압전류의 분석결과로부터 에너지효율은 수소/산소혼합물의 수소농도에 예민하게 의존함을 알 수 있었다.

  • PDF

수소와 산소를 이용한 가스터빈의 구동에 관한 실험 연구 (An Experimental Study about the Running of a Gas Turbine by using Hydrogen and Oxygen)

  • 강진성;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제8권1호
    • /
    • pp.5-10
    • /
    • 1997
  • Because of environmental pollution and reserve limitations of fossil fuels, several alternative energies have been developing. One of them, the hydrogen is researched as a highly probable solution. In this study pure hydrogen gas and oxygen gas are burned in combustor to reduce the emission, and a gas turbine is used. Cooling water around the combustor recovers the cooling heat loss to useful work by being expanded from liquid to vapor, being injected into the combustor and making pressure rise with working fluid to get more turbine power. Because pure hydrogen and oxygen are used, there is no carbonic emission such as CO, $CO_2$, HC nor $NO_x$, and $SO_x$. The power is obtained by turbine system, which makes lower noise and vibration than any reciprocating engine. Running of a turbine is searched under various conditions of hydrogen flow rate and water injection rate. Maximum speed of the turbine is obtained when the combustion reaches steady state. It is enable to determine the optimum rate between hydrogen flow and water injection which makes turbine run maximum speed.

  • PDF

배기가스 내 산소 농도 기반 메탄-수소 연료 전환 제어 프로그램 개발 (Development of Control Program for Methane-hydrogen Fuel Conversion Based on Oxygen Concentration in Exhaust Gas)

  • 신은주;김영배
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.38-46
    • /
    • 2023
  • Carbon neutrality policies have been strengthened to reduce emissions, and the importance of technology road maps has been emphasized. In the global industrial boiler market, carbon neutrality is implemented through fuel diversification of methane-hydrogen mixture gas. However, various problems such as flashback and flame unstability arise. There is a limit to implementing the actual system as it remains in the early stage. Therefore, it is necessary to secure the source technology of methane-hydrogen hybrid combustion system applicable to industrial fields. In this study, control program for methane-hydrogen fuel conversion was developed to expect various parameters. After determining the hydrogen mixing ratio and the input air flow, the fuel conversion control algorithm was constructed to get the parameters that achieve the target oxygen concentration in the exhaust gas. LabVIEW program was used to derive correlations among hydrogen mixing rate, oxygen concentration in exhaust gas, input amount of air and heating value.

수산화가스 발생기의 모델링 및 특성해석 (A Study on Analysis of the Hydrogen-Oxygen Gas Generator)

  • 강병회;이정민;목형수;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.198-201
    • /
    • 2001
  • The mixed gas of Hydrogen and Oxygen is gained from water electrolysis reaction. It has constant volume ratio 2 : 1 Hydrogen and Oxygen, and it is used as a source of thermal energy by combustion reaction. This gas has better characteristics in the field of economy, efficiency of energy, and environmental intimacy than acetylene gas and LPG used for gas welding machine. So several studies of this gas are actively in progress nowadays. The object of this study is the optimization of power condition in the side of electrical for the high efficiency of water electrolysis equipment. First, chemical analysis of electrolysis is conducted, and the relation of electrical energy and chemical energy is quantitatively investigated. For basic experiment, unit electrode of singular electrolysis electrode is manufactured and experimented, results are compared and analyzed with simulation, and the electrolysis is electrically equivalent.

  • PDF

매체순환식 가스연소기용 대량생산입자의 연료별 환원반응특성 (Reduction Characteristics of Mass Produced Particle for Chemical-Looping Combustor with Different Fuels)

  • 류호정;김경수;이승용;박영성;박문희
    • 한국수소및신에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.348-358
    • /
    • 2008
  • Reduction reactivity and carbon deposition characteristics of mass produced oxygen carrier particle(OCN-650) have been investigated by using hydrogen, methane, syngas, and natural gas as fuels. For all fuels, the maximum conversion and oxygen transfer capacity increased as the temperature increase. The reduction rate and the oxygen transfer rate increased as the temperature increase for methane. However, those values showed maximum at 900$^{\circ}C$ for hydrogen, syngas, and natural gas. To explain consistently the change of maximum conversion, reduction rate, oxygen transfer capacity, oxygen transfer rate and degree of carbon deposition for different fuels, new parameters such as reactive carbon contents and require oxygen per input gas were adopted.

Effect of Hydrogen Treatment on Electrical Properties of Hafnium Oxide for Gate Dielectric Application

  • Park, Kyu-Jeong;Shin, Woong-Chul;Yoon, Soon-Gil
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권2호
    • /
    • pp.95-102
    • /
    • 2001
  • Hafnium oxide thin films for gate dielectric were deposited at $300^{\circ}C$ on p-type Si (100) substrates by plasma enhanced chemical vapor deposition (PECVD) and annealed in $O_2$ and $N_2$ ambient at various temperatures. The effect of hydrogen treatment in 4% $H_2$ at $350^{\circ}C$ for 30 min on the electrical properties of $HfO_2$for gate dielectric was investigated. The flat-band voltage shifts of $HfO_2$capacitors annealed in $O_2$ambient are larger than those in $N_2$ambient because samples annealed in high oxygen partial pressure produces the effective negative charges in films. The oxygen loss in $HfO_2$films was expected in forming gas annealed samples and decreased the excessive oxygen contents in films as-deposited and annealed in $O_2$ or $N_2$ambient. The CET of films after hydrogen forming gas anneal almost did not vary compared with that before hydrogen gas anneal. Hysteresis of $HfO_2$films abruptly decreased by hydrogen forming gas anneal because hysteresis in C-V characteristics depends on the bulk effect rather than $HfO_2$/Si interface. The lower trap densities of films annealed in $O_2$ambient than those in $N_2$were due to the composition of interfacial layer becoming closer to $SiO_2$with increasing oxygen partial pressure. Hydrogen forming gas anneal at $350^{\circ}C$ for samples annealed at various temperatures in $O_2$and $N_2$ambient plays critical role in decreasing interface trap densities at the Si/$SiO_2$ interface. However, effect of forming gas anneal was almost disappeared for samples annealed at high temperature (about $800^{\circ}C$) in $O_2$ or $N_2$ambient.

  • PDF