• 제목/요약/키워드: Hydrogen ion

검색결과 767건 처리시간 0.025초

LiAlH4-PVDF 전해질 복합체의 열확산 및 전기화학적 특성평가 (Evaluation of Thermal Diffusivity and Electrochemical Properties of LiAlH4-PVDF Electrolyte Composites)

  • 황준현;홍태환
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.574-582
    • /
    • 2022
  • A lithium-ion battery exhibits high energy density but has many limitations due to safety issues. Currently, as a solution for this, research on solid state batteries is attracting attention and is actively being conducted. Among the solid electrolytes, sulfide-based solid electrolytes are receiving much attention with high ion conductivity, but there is a limit to commercialization due to the relatively high price of lithium sulfide, which is a precursor material. This study focused on the possibility of relatively inexpensive and light lithium hydride and conducted an experiment on it. In order to analyze the characteristics of LiAlH4, ion conductivity and thermal stability were measured, and a composites mixed with PVDF, a representative polymer electrolyte, was synthesized to confirm a change in characteristics. And metallurgical changes in the material were performed through XRD, SEM, and BET analysis, and ion conductivity and thermal stability were measured by EIS and LFA methods. As a result, Li3AlH6 having ion conductivity higher than LiAlH4 is formed by the synthesis of composite materials, and thus ion conductivity is slightly improved, but thermal stability is rapidly degraded due to structural irregularity.

EVALUATION OF FERROCYANIDE ANION EXCHANGE RESINS REGARDING THE UPTAKE OF Cs+ IONS AND THEIR REGENERATION

  • Won, Hui-Jun;Moon, Jei-Kwon;Jung, Chong-Hun;Chung, Won-Yang
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.489-496
    • /
    • 2008
  • Ferrocyanide-anion exchange resin was prepared and the prepared ion exchange resins were tested on the ability to uptake $Cs^+$ ion. The prepared ion exchange resins were resin-KCoFC, resin-KNiFC, and resin-KCuFC. The three tested ion exchange resins showed ion exchange selectivity on the $Cs^+$ ion of the surrogate soil decontamination solution, and resin-KCoFC showed the best $Cs^+$ ion uptake capability among the tested ion exchange resins. The ion exchange behaviors were explained well by the modified Dubinin-Polanyi equation. A regeneration feasibility study of the spent ion exchange resins was also performed by the successive application of hydrogen peroxide and hydrazine. The desorption of the $Cs^+$ ion from the ion exchange resin satisfied the electroneutrality condition in the oxidation step; the desorption of the $Fe^{2+}$ ion in the reduction step could also be reduced by adding the $K^+$ ion.

Binding sites for lead ion in staphylococcus epidermidis

  • Kim, Mal-Nam;Sung, Hye-Yoon
    • Journal of Microbiology
    • /
    • 제33권3호
    • /
    • pp.228-233
    • /
    • 1995
  • As S. epidermidis cell was fractionated into cell wall, cell membrane, and cytoplasm, the cell membrane proved to be the most efficient absorbent for lead ion. Utrasonication was effective, when the cells were treated during their exponential growth. The amount of the lead ion adsorbed in cell membrane decreased as hydrogen ion concentration of solution increased. Protein purified from the cell membrane showed higher adsorption capacity for the lead ion than peptidoglycan, teichoic acid from cell wall, or cell membrane lipid. Modification of carboxyl groups in the membrane protein with ethylenediamine and 1-ethyl-3-carbodiimide hydrochloride resulted in a considerable decrease of lead ion adsorption capability, suggesting that the main binding site for lead ion was the carboxyl groups of protein in cell membrane.

  • PDF

Hydrogen Transport through Palladium Foil Placed in Nafion Electrolyte of H2/O2 Fuel Cellsorption

  • Song, Seong-Min;Koo, Il-Gyo;Lee, Woong-Moo
    • 한국수소및신에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.257-265
    • /
    • 2001
  • Placing a hydrogen conducting, methanol impermeable metallic barrier like palladium (Pd) is a well-known method for preventing methanol crossover through solid polymer electrolyte for direct methanol fuel cells (DMFC). Applying a bias potential between the anode and the barrier can further develop this concept so that the hydrogen transfer rate is enhanced. Since hydrogen diffuses in Pd as atomic form while it moves through nafion electrolyte as ion, it has to be reduced or oxidized whenever it passes the interface formed by Pd and the electrolyte. We performed experiments to measure the hydrogen transport through the Pd membrane placed in Nafion electrolyte of hydrogen/oxygen fuel cell (PEMFC). Applying a bias potential between the hydrogen electrode of the cell and the Pd membrane facilitated the hydrogen passage through the Pd membrane. The results show that the cell current measured with the Pd membrane placed reached almost 40 % the value measured with the cell without Pd membrane. It was found that the current flown through the bias path is only a few percent of the cell current.

  • PDF

PEEK/HPA를 이용한 수전해용 저온형 고체고분자 전해질막의 제조 (Preparation of Polyether ether ketone[PEEK]/Heteropolyacid [HPA] Blends Membrane for Hydrogen production via Electrodialysis)

  • 이혁재;정윤교;장인영;황갑진;배기광;심규성;강안수
    • 한국수소및신에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.40-48
    • /
    • 2005
  • Until recently, only perfluorinated ionomer membrane such as Nation and Aciflex practically could be successfully used in water splitting. However, these membrane are limited by high cost and loss of membrane performance such as proton conductivity at elevated temperature above 80$^{\circ}C$. The sulfonated aromatic polymers such as PEEK and PSf, polyimides, and polybenzimidazoles are expected to have lower production cost as well as satisfactory chemical and electrochemical properties. HPAs and sulfonated polymers could have a significant influence on water electrolysis performance at elevated temperatures above 80$^{\circ}C$, but these phenomena have received relatively little attention until now. Therefore, it would be desirable to investigate the interrelation between the HPA and sulfonated polymer, such as SPEEK. The SPEEK membrane were prepared by the sulfonation of PEEK, and HPA was blended with SPEEK to increase the mechanical strength and electrochemical characteristics. As a results, electrochemical characteristics such as proton conductivity and ion exchange capacity were improved with the addion of 0.5 g HPA. And the properties of polymer electrolyte, SPEEK/HPA were better than Nation membrane at elevated temperature above 80$^{\circ}C$.

PSf-co-PPSS/HPA를 이용한 수소제조 수전해용 고체 고분자 전해질 복합 막의 제조 (Preparation of Solid Polymer Electrolytes of PSf-co-PPSS/Heterooolyacid [HPA] Composite Membrane for Hydrogen Production via Water Elecrolysis)

  • 정윤교;이혁재;장인영;황갑진;배기광;심규성;강안수
    • 한국수소및신에너지학회논문집
    • /
    • 제16권2호
    • /
    • pp.103-110
    • /
    • 2005
  • Proton conducting solid polymer electrolyte (SPE) membranes have been used in many energy technological applications such as water electolysis, fuel cells, redox-flow battery, and other electrochemical devices. The availability of stable membranes with good electrochemical characteristics as proton conductivity at high temperatures above 80 $^{\circ}C$ and low cost are very important for its applications. However, the presently available perfluorinated ionomers are not applicable because of high manufacturing cost and high temperature use to the decrease in the proton conductivity and mechanical strength. In order to make up for the weak points, the block copolymer (BPSf) of polysulfone and poly (phenylene sulfide sulfone) were synthesized and sulfonated. The electrolyte membranes were prepared with phosphotungstic acid (HPA)/sulfonated BPSf via solution blending. This study would be desirable to investigate the interaction between the HPA and sulfonated polysulfone. The results showed that the characteristics of SPSf/HPA blend membrane was a better than Nafion at high temperature, 100 $^{\circ}C$. These membranes proved to have a high proton conductivity, $6.29{\times}10-2$ S/cm, a water content, 23.9%, and a ion exchange capacity, 1.97 meq./g dry membrane. Moreover, some of the membranes kept their high thermal and mechanical stability.

수소가 장입된 Zircaloy-4 합금의 부식 후의 Ac Impedance 특성 (AC Impedance Characteristics of the Corroded Hydrogen-Charged Zircaloy-4 Alloy)

  • 김선재;김경호;백종혁;최병권;정용환
    • 한국재료학회지
    • /
    • 제9권2호
    • /
    • pp.205-210
    • /
    • 1999
  • The 250ppm hydrogen-charged Zircaloy-4 sheets, homogenized at $400^{\circ}C$ for 72hrs in vacuum, were corroded under the autoclave conditions of $350^{\circ}C$, 2350psi. The corrosion behavior of the Zircaloy-4 sheets was evaluated by measuring their weight gains with the exposure time. The electrical characteristics were investigated in the ranges of 5000~1x10\ulcornerHz using AC impedance technique in 1N $H_2$$SO_4$aqueous solution. The corrosion rate of the hydrogen charged specimen was more rapid than the normal specimen at the early stage of the corrosion. With a longer corrosion time, however, the normal specimen corroded faster than the hydrogen-charged specimen. At the same time the hydrogen pickup in the hydrogen-charged specimen was more suppressed compared with the normal specimen. Such appears to be occurred because the impedance for the movement of the hydrogen ion into the metal was higher in the hydrogen-charged specimen compared to normal specimen at the interface between the oxide layer and the uncorroded metal. Thus the corrosion rate of the hydrogen-charged specimen was likely to be decreased with a longer corrosion time.

  • PDF

Effect of a Series Connection of a Bi-Electrolyte Hydrogen Sensor in a Leak Detector

  • Han, Hyeuk Jin;Park, Chong Ook;Hong, Youngkyu;Kim, Jong Suk;Yang, Jeong Woo;Kim, Yoon Seo
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.6-9
    • /
    • 2015
  • Conventional leak detectors are widely based on helium gas sensors. However, the usage of hydrogen sensors in leak detectors has increased because of the high prices of helium leak detectors and the dearth in the supply of helium gas. In this study, a hydrogen leak detector was developed using solid-state hydrogen sensors. The hydrogen sensors are based on Park-Rapp probes with heterojunctions made by oxygen-ion conducting Yttria-stabilized zirconia and proton-conducting In-doped $CaZrO_3$. The hydrogen sensors were used for determining the potential difference between air and air balanced 5 ppm of $H_2$. Even though the Park-Rapp probe shows an excellent selectivity for hydrogen, the sensitivity of the sensor was low because of the low concentration of hydrogen, and the oxygen on the surface of the sensor. In order to increase the sensitivity of the sensor, the sensors were connected in series by Pt wires to increase the potential difference. The sensors were tested at temperatures ranging from $500-600^{\circ}C$.

사염화규소 누출사고지점 주변 식물에 대한 노출지표 평가 (Evaluation of Exposure Indicators for Plants by Silicon Tetrachloride Release)

  • 박재선;김지영;김명옥;박현우;정현미;최종우
    • 한국환경농학회지
    • /
    • 제36권4호
    • /
    • pp.288-292
    • /
    • 2017
  • BACKGROUND: Silicon tetrachloride reacts with moisture in the atmosphere to generate hydrogen chloride, which affects the environment. Since silicon tetrachloride and its by-products are dispersed in the atmosphere in a short time after the silicon tetrachloride release into the atmosphere, it is difficult to directly assess the extent of environmental impact. In the present study, the exposure test of silicon tetrachloride or hydrogen chloride was examined in order to establish the criterion of the range affected by the silicon tetrachloride release, and the actual crops in the area exposed to silicon tetrachloride leakage were analyzed. METHODS AND RESULTS: For the experiment of exposure to silicon tetrachloride or hydrogen chloride, the leaves of red-pepper and corn were used in glass sealed containers. In the actual accident area, 59 samples from 10 different kinds of crops were collected. The pretreatment of the sample was performed by freezing and grinding, and then extracted using distilled water. The pH and concentration of chloride ($Cl^-$) ion of the extracted solution were measured using pH meter and ion chromatograph, respectively. CONCLUSION: Exposure to silicon tetrachloride caused visible damage, increasing the concentration of chloride ion, and decreasing the pH as well as hydrochloric acid. In the actual crops of the affected area, the tendency was the same as the result of the laboratory test, and the range of influence could be estimated through the concentration of $Cl^-$ ion over 2,000 mg/kg, and the correlation evaluation between the concentration of $Cl^-$ and pH. Therefore, the concentration of $Cl^-$ ion and the correlation between $Cl^-$ and pH would be considered as the factors to estimate the influence range of silicon tetrachloride release.

카드뮴 전해석출에서의 이성분첨가물계의 효과 (The Effect of Some Binary Additive Systems in the Electrodeposition of Cadmium)

  • 이경호
    • 분석과학
    • /
    • 제9권2호
    • /
    • pp.161-167
    • /
    • 1996
  • 이성분계 첨가물을 이용한 카드뮴 석출과 수소 생성의 상대족인 속도를 조절할 수 있는 가능한 방법에 대하여 조사하였다. 수소를 발생하는 물의 전기환원을 억제하는 소수성 필름을 형성할 수 있는 벤질 알코올을 첨가제 중의 하나로 선택하였다. 다른 한 가지 첨가제는 카드뮴(II) 이온의 친수성을 약화시킴으로써 소수성 벤질 알코올 필름층을 쉽게 가로질러 환원극에 전착시킬 수 있는 것을 선택하였다. 전압 전류 효율 연구로부터 이온쌍과 착물 첨가제가 벤질 알코올 필름 존재하에서 카드뮴의 환원을 촉진시킬 수 있다는 것을 확인하였다. 벤질 알코올 필름은 나트륨 이온과 카드뮴의 염화착물을 형성하는 이온쌍을 얻기에 충분하도록 전극 주위의 유전상수를 낮추고, 카드뮴의 환원을 촉진시킨다. 이러한 환원의 촉진은 염화물이 존재하지 않는 황산염 용액에서는 일어나지 않는다. 왜냐하면 카드뮴은 본래 아쿠아 착물과 이온쌍으로 존재하여 카드뮴의 환원을 촉진시키지 못하고 환원을 방해시키기 때문이다.

  • PDF