• Title/Summary/Keyword: Hydrogen distribution

Search Result 539, Processing Time 0.028 seconds

Micro-Hardnesses and Microstructural Characteristics of Surface Layer of 590MPa DP Steels According to Hydrogen Charging (수소주입에 따른 590 MPa급 DP강 표면층의 미소경도와 조직특성)

  • Kang, Kae-Myung;Park, Jae-Woo
    • Korean Journal of Materials Research
    • /
    • v.20 no.11
    • /
    • pp.581-585
    • /
    • 2010
  • High strength sheet steels for automobile are seriously compromised by hydrogen embrittlement. This issue has been continuously studied, but the field of interest, which lies between microstructural characteristics and hydrogen behavior with hydrogen charging, has not yet been thoroughly investigated. This study was done to investigate the behavior of hydrogen according to the hydrogen volume fraction on 590MPa grade DP steels, which are developed under hydrogen charging conditions as high strength sheet steels for automobiles. The penetration depths and the mechanical properties, according to charging conditions, were investigated through the distribution of micro-hardness and the microstructural observation of the subsurface zone. It was found that the amount of hydrogen trapping in 590MPa DP steels was related to the austenite volume fraction. It was confirmed that the distribution of micro-hardnesses according to the depth of the subsurface zone under the free surface showed the relationship of the depth of the hydrogen saturation between the charging conditions.

Antimicrobial Effect of Lactic acid and Hydrogen Peroxide and Distribution of Vibrio parahaemolyticus from the Incheon Adjacent Sea (인천연안 Vibrio parahaemolyticus의 분포 및 유산과 과산화수소 처리에 의한 항균효과)

  • Jang, Jae-Seon;Cho, Woo-Kyoun;Lee, Hye-Jeong;Lee, Jea-Mann;Kim, Hye-Young;Kim, Yong-Hee
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.11-18
    • /
    • 2006
  • This study was carried out to investigate the distribution of Vibrio parahaemolyticus in the Incheon adjacent sea, and antimicrobial effect on growth of Vibrio parahaemolyticus in lactic acid and hydrogen peroxide and combination of lactic acid and hydrogen peroxide. The detected strains were compared geographical, months and sample types. The distribution of Vibrio parahaemolyticus was high at Ganghwa county with 66.1%(336 samples), on 7-9 months with 72.4%(386 samples) and from tireland with 75.0%(90 samples), respectively. The minimun inhibitory concentration (MIC) of lactic acid in Vibrio parahaemolyticus were 1250 ppm at pH 6.5 and 7.0, 625 ppm at pH 6.0. respectively. The minimun inhibitory concentration (MIC) of hydrogen peroxide in Vibrio parahaemolyticus were 25 ppm at pH 6.5 and 7.0, 12.5 ppm at pH 6.0, respectively. MICs of combined treatment of lactic acid and hydrogen peroxide in Vibrio parahaemolyticus were 625 ppm of lactic acid with 12.5 ppm of hydrogen peroxide. The correlations between MICs of lactic acid and hydrogen peroxide in Vibrio parahaemolyticus were obtained through the coefficient of determination($R^2$). $R^2$ value were 1.0000. The antimicrobial effect of lactic acid and hydrogen peroxide in Vibrio parahaemolyticus could be confirmed from the result of this experiment.

Numerical Analysis on the $2^{nd}$ Discharae-passase In Reciprocating Compressor (왕복동식 수소압축기의 2단 토출통로 유동해석)

  • Lee, G.H.;Rahman, M. Sq.;Kim, C.P.;Joung, T.W.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.3
    • /
    • pp.27-32
    • /
    • 2009
  • Numerical analysis information of a complex discharge-passage will be very useful to improve hydrogen compression system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas from cylinder going to the chamber of a reciprocating compressor are presented in this paper. Discharge-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the hydrogen compressing system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement should be done. Consequently, development of the better hydrogen compressing system will be achieved.

  • PDF

Quantification for the Distribution of Hydrogen Bonding Species in Phenolic Model Compounds and Polybenzoxazines (페놀계 모델 화합물 및 폴리벤조옥사진 수지에 대한 수소결합분포의 정량화)

  • Kim, Ho-Dong;Moon, Hwa-Yeon
    • Textile Coloration and Finishing
    • /
    • v.20 no.4
    • /
    • pp.21-30
    • /
    • 2008
  • To understand the complex hydrogen bonding structure, several phenolic derivatives and benzoxazine model compounds are synthesized and characterized by Fourier transform infrared spectroscopy (FT-IR). The estimation of molar extinction coefficients for various types of hydrogen bonding species is systematically carried out by the curve-resolving of FT-IR spectra. The distribution of hydrogen bonding species in benzoxazine model dimers is quantitatively analyzed. It is revealed that benzoxazine dimers and BA-a polybenzoxazine are mainly composed of intramolecular interaction rather than intermolecular interaction.

A Numerical Analysis of Pressure Distribution and Pressure Drop in Receptacle for Hydrogen Charging System (수소 충전 시스템용 리셉터클의 내부 압력 분포와 압력 강하에 관한 수치적 연구)

  • YUANGANG WANG;SEUNGHYEOK LEE;CHAE HOON SOHN;SEDONG LEE;HYUNBOK LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.497-504
    • /
    • 2023
  • This study analyzes pressure distribution and pressure drop in the receptacle used in charging system of hydrogen fuel cell vehicles. The objective is to minimize receptacle-induced pressure drop by redesigning internal flow channels. Through numerical simulations, three receptacle variants are compared with a baseline case. Results show reduced pressure drop in the filter section. However, the check valve section exhibits higher pressure drop, requiring further improvement. By increasing throat diameter, pressure drop is decreased by 28% between inlet and outlet of the receptacle. This study shows the relationship between dynamic pressure and pressure drop, providing a guideline for receptacle performance optimization. The redesigned receptacle offers potential for enhancing hydrogen charging efficiency.

Study on Metal Cupferrate Complex (Part III) Study on Distribution Ratio of Hydrogen Cupferrate in $H_2O-CHCl_3$ System (Metal Cupferrate Complex 에 關한 硏究 (第 3 報) $H_2O$-Chloroform 系에서의 Hydrogen Cupferrate 의 分配係數에 關한 硏究)

  • Si-Joong Kim;Doo-Soon Shin
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.4
    • /
    • pp.283-287
    • /
    • 1963
  • The distribution ratio of hydrogen cupferrate in $H_2O-CHCl_3$ system was considered as a function of pH ($HClO_4$), ionic strength ($NaClO_4$), and cupferron concentration in perchloric acid media, respectively. The values were independent upon pH (1.50∼3.00 range) and ionic strength (0.1∼2.00 range), but they increased as increasing the cupferron concentration in the acidic media. At the infinite dilution, the thermodynamic distribution ratio between chloroform and aqueous phase was 120. 0. The activity coefficients of hydrogen cupferrate in chloroform solution were determined by the distribution ratio. This activity coefficient may be calculated by using the empirical equation, $-log\;f_{CHCl3}=0.1285C_{CHCl3}+{7.775C^2}_{CHCl3}$ which represents the experimental data quite well for the solution in 0.1 mole/l order of hydrogen cupferrate concentration.

  • PDF

Numerical Analysis on the Working Fluid Flow of Suction-passage for Reciprocating Compressor (왕복동식 수소압축기의 흡입통로내 작동유체 유동해석)

  • Lee, Gyeong-Hwan;Rahman, Mohammad Shiddiqur;Shim, Kyu-Jin;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1201-1207
    • /
    • 2008
  • Numerical analysis information will be very useful to improve fluid system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas coming to the cylinder of a reciprocating compressor are presented in this paper. Suction-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement, such as reducing the varying flow parameters and flow reorientation should be done. Consequently, development of the better hydrogen compressing system will be achieved.

THE NUMERICAL SIMULATION OF HYDROGEN DIFFUSION FOR THE HYDROGEN LEAKAGE IN TUNNEL (터널 내 수소연료 자동차의 수소 누설로 인한 수소 확산에 대한 수치해석 연구)

  • Ahn, Hyuk-Jin;Jung, Jae-Hyuk;Hur, Nahm-Keon;Lee, Moon-Kyu;Yong, Gee-Joong
    • Journal of computational fluids engineering
    • /
    • v.15 no.2
    • /
    • pp.47-54
    • /
    • 2010
  • In the present study, a numerical simulation for the diffusion of hydrogen leakage of FCV(Fuel Cell Vehicle) in a tunnel was performed to aid the assessment of risk in case of leakage accident. The temporal and spatial distributions of the hydrogen concentration around FCV are predicted from the present numerical analyses. Flammable region of 4-74% and explosive region of 18-59% hydrogen by volume was identified from the present results. Factors influencing the diffusion of the hydrogen jet were examined to evaluate the effectiveness of tunnel ventilation system for relieving the accumulation of the leaked hydrogen gas. The distribution of the concentration of the leaked hydrogen for various cases can be used as a database in various applications for the hydrogen safety.

Proposal and Analysis of Hydrogen Mitigation System Guiding Hydrogen in Containment Building

  • Park, Kweonha;Lee, Khor Chong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.516-521
    • /
    • 2015
  • This study is about a hydrogen mitigation system in a containment building like an offshore or a nuclear plant. A hydrogen explosion is possibly happened after condensation of steam if hydrogen releases with steam in a containment buildings. Passive autocatalytic recombiner is the one of the measures, but the performance of this equipment is not sure because the distribution of hydrogen is very irregular and is not predicted correctly. This study proposes a new approach for improving the hydrogen removing performance with hydrogen-guiding property. The steam is simulated and analysed. The results show that the shallow air containment reduced over 55% of the released hydrogen and the deep air containment type reduces over 80% of released hydrogen.

Sludge Granulation Depending Hydrogen Feeding on The Varying Periods of Hydrogen Feeding and Starvation (수소기질 결핍 및 공급 기간비 변화에 따른 슬러지 입상화)

  • Jeong, Byung-Gon;Lee, Heon-Mo;Yang, Byung-Soo
    • Journal of Environmental Science International
    • /
    • v.5 no.3
    • /
    • pp.387-398
    • /
    • 1996
  • Granular sludge formation and it's activity change are the most important factors in achieving successful start-up and operation of UASB reactor. Nevertheless, the detailed mechanism is still unknown. On the basic of the experiments in laboratory-scale UASB reactor, the effect of hydrogen partial pressure on sludge granulation was evaluated. Size distribution method and specific metabolic activity of the sludge with the operation time were used as a means for estimating the degree of the sludge granulation. At the constant hydrogen loading, the granulation increased as starvation periods in hydrogen supply increased, resulting in high organic removal efficiency. It was evidient that hydrogen play very important role in granulation and sludge granulation was achieved through mutual symbiosis between hydrogen utilizing bacteria and hydrogen producing bacteria under the hydrogen dificient conditions. Key words : granular sludge, UASB reactor, hydrogen partial pressure.

  • PDF