• Title/Summary/Keyword: Hydrogen Sulfide Gas

Search Result 227, Processing Time 0.027 seconds

Development of Porous Sorbents for Removal of Hydrogen Sulfide from Hot Coal Gas -I. Additive Effect of Sorbents for the Removal of Hydrogen Sulfide- (고온석탄 가스에서 황화물의 제거하기 위한 다공성 흡착제의 개발-1. 황화수소가스 흡착제의 첨가물 효과-)

  • 이재복;류경옥
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 1988
  • 석탄유도가스에 포함된 황화수소를 제거시킬 흡착제를 개발하기 위하여 알칼리 토금속, 천이원소 및 아연의 이온반경보다 이온반경이 작은 금속산화물을 산화아연에 첨가시켜 다공성 흡착제를 제조하였다. 600$\circ$C에서 이들 첨가시료를 2.09vol.% 황화수소와 질소가스 혼합기체로 반응시켜 초기속도를 측정하고, 같은 온도에서 사용된 흡착제를 공기로 재생시켰다. 사용된 금속산화물 첨가 흡착제중에서 CaO, TiO$_2$, $Fe_2O_3$, CuO, $Ga_2O_3$ 및 Si$_2$O가 ZnO 흡착제의 초기속도를 증가시켜 첨가제로 사용할 수 있음을 보였다.

  • PDF

A Study on Statistics for Accidents in Confined Space in Korea (밀폐공간 질식재해 통계현황 분석)

  • Yoo, Kye-mook;Park, Hyun-hee;Chung, Kwang-Jae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.4
    • /
    • pp.363-369
    • /
    • 2009
  • The total number of confined space accident cases from 1999 to 2007 in Korea were 220, causing 353 injuries and 212 casualties. Out of 220 cases, 44(20.0%) occurred in sewage treatment facilities and 40(18.2%) occurred in both manholes and containers. When the main causes of confined space accidents were classified, oxygen deficiency accounted for 69 cases(31.4%), carbon monoxide, 48(21.8%), hydrogen sulfide, 40(18.2%), and organic solvent, 32(14.5%). Improvement of occupational accident statistics is necessary in order to report accurate and precise data for confined space accidents. The structure of confined space must be considered when selecting gas to be measured.

Effect of Hydrogen Sulfide Removal by Biofilter Seeded with Pseudomonas putida B2 (Pseudomonas putida B2가 접종된 Biofilter의 황화수소제거 효과)

  • Yoon, Ji-Yong;Lee, Soo-Choul;Kwon, Il;Sung, Chang-Keun
    • KSBB Journal
    • /
    • v.16 no.3
    • /
    • pp.286-289
    • /
    • 2001
  • A beterotrophic Pseudomonas putida B2 was used to treat of hydrogen sulfide containing gas. The experimental approach involved operating two indentical bench-scale biofilters with media consisting of a mixture of peatmoss, perlite and granular activated carbon(GAC). One column was seeded with Pseudomonas putida B2 and the other was left unseeded. The biofilter was operated for 16 days under EBRT for 20-40 sec, at a temperature of 25-30$^{\circ}C$ and a hydrogen sulfide concentration of 40-190 ppm. The biofilter inocculated with P.putida B2 exhibited high hydrogen sulfide removal efficiency, average of 95%, at a gydrogen sulfide concentration of 40-190 ppm (flow rate 3.6 L/min). However, at a shock loading of 190 ppm the biofiter showed a removal efficiency of 78.9% and the control only showed a removal efficiency of 31.6%. The critical load of this biofilter was 14.83 g/㎥hr, and the critical load of the control column was 4.93 g/㎥hr. These results suggest that P. putida B2 has the potential to be used as a $H_2S$ removal agent in a biofilter.

  • PDF

Tin Germanium Sulfide Nanoparticles for Enhanced Performance Lithium Secondary Batteries (고성능 리튬 이차 전지를 위한 황화 주석 저마늄 (SnxGe1-xS) 나노입자 연구)

  • Cha, E.H.;Kim, Y.W.;Lim, S.A.;Lim, J.W.
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • Composition-controlled ternary components chalcogenides germanium tin sulfide ($Sn_xGe_{1-x}S$) nanoparticles were synthesized by a novel gas-phase laser photolysis reaction of tetramethyl germanium, tetramethyl tin, and hydrogen sulfide mixture. Subsequent thermal annealing of as-grown amorphous nanoparticles produced the crystalline orthorhombic phase nanoparticles. All these composition-tuned nanoparticles showed excellent cycling performance of the lithium ion battery. The germanium sulfide nanoparticles exhibit a maximum capacity of 1200 mAh/g after 70 cycles. As the tin composition (x) increases, the capacity maintains better at the higher discharge/charge rate. This novel synthesis method of tin germanium sulfide nanoparticles is expected to contribute to expand their applications in high-performance energy conversion systems.

The Utilization of Waste Seashell for High Temperature Desulfurization

  • Kim, Young-Sik;Hong, Sung-Chul
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.136-140
    • /
    • 2010
  • The integrated gasification combined cycle (IGCC) is one of the most promising proposed processes for advanced electric power generation that is likely to replace conventional coal combustion. This emerging technology will not only improve considerably the thermal efficiency but also reduce or eliminate the environmentally adverse effects normally associated with coal combustion. The IGCC process gasifies coal under reducing conditions with essentially all the sulfur existing in the form of hydrogen sulfide ($H_2S$) in the product fuel gas. The need to remove $H_2S$ from coal derived fuel gases is a significant concern which stems from stringent government regulations and also, from a technical point of view and a need to protect turbines from corrosion. The waste seashells were used for the removal of hydrogen sulfide from a hot gas stream. The sulphidation of waste seashells with $H_2S$ was studied in a thermogravimetric analyzer at temperature between $600^{\circ}C$ and $800^{\circ}C$. The desulfurization performance of the waste seashell sorbents was experimentally tested in a fixed bed reactor system. Sulfidation experiments performed under reaction conditions similar to those at the exit of a coal gasifier showed that preparation procedure and technique, the type and the amount of seashell, and the size of the seashell affects the $H_2S$ removal capacity of the sorbents. The pore structure of fresh and sulfided seashell sorbents was analyzed using mercury porosimetry, nitrogen adsorption, and scanning electronmicroscopy.

Removal of Inorganic Odorous Compounds by Scrubbing Techniques using Silver Nano-particles (나노 은 입자 세정법을 이용한 무기 악취물질의 제거)

  • Shin, Seung-Kyu;Huyen, Tran;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.6
    • /
    • pp.674-681
    • /
    • 2008
  • Silver as a metal catalyst has been used to remove odorous compounds. In this study, silver particles in nano sizes ($5{\sim}30nm$) were prepared on the surface of $NaHCO_3$, the supporting material, using a sputtering method. The silver nano-particles were dispersed by dissolving $Ag-NaHCO_3$ into water, and the dispersed silver nano-particles in the aqueous phase was applied to remove inorganic odor compounds, $NH_3$ and ${H_2}O$, in a scrubbing reactor. Since ammonia has high solubility, it was removed from the gas phase even by spraying water in the scrubber. However, the concentration of nitrate (${NO_3}^-$) ion increased only in the silver nano-particle solution, implying that the silver nano-particles oxidized ammonia. Hydrogen sulfide in the gas phase was rapidly removed by the silver nano-particles, and the concentration of sulfate (${SO_4}^{2-}$) ion increased with time due to the oxidation reaction by silver. As a result, the silver nano-particles in the aqueous solution can be successfully applied to remove odorous compounds without adding additional energy sources and producing any harmful byproducts.

Effect of Manure Additives Mixed with Probiotics and Zeolite on Harmful Gas Production Released From Pig Slurry (생균제와 제올라이트를 혼합한 축분첨가제가 돈분 슬러리에서 발생하는 유해 가스 발생량에 미치는 영향)

  • Jang, Woo-Whan;Choi, In-Hag
    • Journal of Environmental Science International
    • /
    • v.31 no.1
    • /
    • pp.99-102
    • /
    • 2022
  • The aim of this study was to investigate the effect of manure additives mixed with probiotics and zeolite on harmful gas production generated by pig slurry. A total of 180 crossbred pigs ([Yorkshire × Land race] × Duroc, live weight 70±3.21 kg) were allotted to a completely randomized design with 3 treatments and 3 replications (20 heads per replicate). The treatments consisted of 0% (control), 0.05% (T1), or 1% (T2) of manure additives mixed with probiotics and zeolite. Manure additives were added weekly to pig slurry pits (2 m × 4.5 m × 1.2 m) on a volumetric basis. For ammonia measured at both 10 cm and 90 cm above the pig slurry pit, a statistical significance (p<0.05) was found in probiotics and zeolite-treated manure additives at weeks 1 - 3, except for week 0. In addition, hydrogen sulfide levels measured at 10 cm above the pig slurry pit were not affected by the manure additive at weeks 0 and 1, but showed a significant statistical difference at weeks 2 and 3 (p<0.05). Therefore, supplementing pig slurry with 0.05% and 0.1% manure additives mixed with probiotics and zeolite was found to be effective in reducing environmental pollution in pig facilities.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

Odorous Gas Removal in Biofilter with Powdered Activated Carbon and Zeolite Coated Polyurethane Foam (분말활성탄 및 제올라이트 담지 폴리우레탄 담체를 이용한 바이오필터에서의 악취가스 제거)

  • Lee, Soo-Chul;Kim, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.209-215
    • /
    • 2012
  • The performance and removal efficiencies of a pilot scale biofilter were estimated by using ammonia and hydrogen sulfide as the odorous gases. Expanded polyurethane foam coated with powdered activated carbon and zeolite was used as a biofilm supporting medium in the biofilter. Odorous gases from the sludge thickener of a municipal wastewater treatment plant were treated in the biofilter for 10 months and the inlet ammonia and hydrogen sulfide concentrations were 0.1-1.5 and 2-20 ppmv, respectively. The removal efficiencies reached about 100% at the empty bed retention time (EBRT) of 3.6-5 seconds except for the adaptation periods. The pressure drop of the biofilter caused by the gas flow was also low that the maximum attained was 31 mm $H_2O$ during the operation. Its stability was confirmed in the long term due to the fact that the biofilter and the polyurethane medium had a minimum plugging and compression. The microbial community on the medium is critical for the performance of the biofilter especially the distribution of ammonia oxidizing bacteria (AOB) and sulfur oxidizing bacteria (SOB). The distribution of Nitrosomonas sp. (AOB) and Thiobacillus ferroxidans (SOB) was confirmed by FISH (fluorescence in situ hybridization) analysis. The longer the operation time, the more microbial population observed. Also, the medium close to the gas inlet had more microbial population than the medium at the gas outlet of the biofilter.

Analysis of Offensive Odorous Compounds Emitted From the Chemical Plants (화학공장에서 배출되는 악취규제물질의 분석 및 평가)

  • Choi, Jae-Sung;Kim, Jae-Woo
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • The concentrations of offensive odorous compounds emitted from the two chemical plants in Chongju and Yeosu industrial complex in Korea were determined by uv/vis spectroscopy, gas chromatography, and high performance liquid chromatography. The odorous compounds examined in this study are ammonia, trimethyl amine, formaldehyde, acetaldehyde, propion aldehyde, butyl aldehyde, n-valeric aldehyde, iso-valeric aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide. The concentrations of those were determined from the 10 sampling points of the two plants, respectively. The emission concentrations of all odorous com-pounds examined in the two plants were lower than those of the regulation standard levels of industrial complex in Korea, respectively. The propion aldehyde, n-valeric aldehyde, methyl mercaptan and dimethyl disulfide in Chongju and Yeosu plants, and butyl aldehyde and iso-valeric aldehyde in Yeosu plant were not detected at any sampling points examined.