• Title/Summary/Keyword: Hydrogen Sulfide

Search Result 593, Processing Time 0.032 seconds

Adsorption Characteristics of Impregnated Activated Carbon Fiber for the Removal of Hydrogen Sulfide at the Working Environment (작업환경 중 황화수소 제거를 위한 첨착활성탄소섬유의 흡착특성)

  • 김기환;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.127-133
    • /
    • 1999
  • One of the major malodorous gas at the working place is hydrogen sulfide and impregnated activated carbon fiber(ACF) was used as a adsorbent to remove this gas. ACF is treated and impregnated with chemicals to increase the adsorption capacity. The experiments showed that the adsorption efficiency for hydrogen sulfide was increased in case of impregnation with $Na_2CO_3$ or KI. Also, by the surface treatment with NaOH, the adsorption efficiency was increased however not so much as impregnation. KI was the best impregnant for this purpose and the optimum concentration was 9wt%. The adsorption capacity of hydrogen sulfide was more than 500mg/g ACF.

  • PDF

Adsorption Characteristics of Hydrogen Sulfide on Iron Hydroxide-based Adsorbent (수산화철계 흡착제의 황화수소 흡착 특성)

  • Ryu, Seung Hyeong;Seo, Youngjoo;Park, Joonwoo;Kim, Shin Dong;Park, Seong Soon
    • Journal of Korea Society of Waste Management
    • /
    • v.34 no.5
    • /
    • pp.468-473
    • /
    • 2017
  • This study was carried out to examine the characteristics of hydrogen sulfide adsorption using an iron hydroxide-based adsorbent. The prepared adsorbent was discussed with regard to its adsorption capacity and analyzed via surface analysis methods to illustrate the physical characteristics of hydrogen sulfide adsorption. As the drying temperature increased, the adsorption capacity of the adsorbent decreased from 29.15wt% to 22.73wt%. The adsorption capacity was decreased as the space velocity increased and showed an adsorption capacity of about 3.65 at $3,157.6h^{-1}$. The effect of sulfur dioxide was to decrease the adsorption capacity from 29.15wt% to 27.94wt%. The adsorbent exhibited the amorphous type in its physical appearance based on XRD and EDS analysis.

Analysis of cause of engine failure during power generation using biogas in sewage treatment plant (하수처리장 바이오가스를 이용한 발전시 가스엔진의 고장원인 분석)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.13-29
    • /
    • 2016
  • In this study, we analyzed the causes of major faults in the biogas plant through the case of gas engine failure when cogenerating electricity and heat using biogas as a fuel in the actual sewage treatment plant and suggested countermeasures. Hydrogen sulfide in the biogas entering the biogas engine and water caused by intermittent malfunction of the water removal system caused intercooler corrosion in the biogas engine. In addition, the siloxane in the biogas forms a silicate compound with silicon dioxide, which causes scratches and wear of the piston surface and the inner wall of the cylinder liner. The substances attached to the combustion chamber and the exhaust system were analyzed to be combined with hydrogen sulfide and other impurities. It is believed that hydrogen sulfide was supplied to the desulfurization plant for a long period of time because of the high content of hydrogen sulfide (more than 50ppm) in the biogas and the hydrogen sulfide was introduced into the engine due to the decrease of the removal efficiency due to the breakthrough point of the activated carbon in the desulfurization plant. In addition, the hydrogen sulfide degrades the function of the activated carbon for siloxane removal of the adsorption column, which is considered to be caused by the introduction of unremoved siloxane waste into the engine, resulting in various types of engine failure. Therefore, hydrogen sulfide, siloxane, and water can be regarded as the main causes of the failure of the biogas engine. Among them, hydrogen sulfide reacts with other materials causing failure and can be regarded as a substance having a great influence on the pretreatment process. As a result, optimization of $H_2S$ removal method seems to be an essential measure for stable operation of the biogas engine.

Ammonia and Hydrogen Sulfide Monitoring in Broiler Barns and Cattle Barns (계사 및 우사 내 암모니아 및 황화수소 노출농도 평가)

  • Park, Jihoon;Seok, Jiwon;Lee, Sangah;Kwon, Ohhun;Lee, Kyungsuk;Heo, Yong;Yoon, Chungsik
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.277-288
    • /
    • 2015
  • Objectives: There are many hazardous agents at livestock farms. In particular, gases can be detrimental to both workers and animals. This study evaluated ammonia and hydrogen sulfide concentrations in broiler hen barns and beef cattle barns according to sampling location and height. Methods: Three broiler hen barns and three beef cattle barns were selected for gas monitoring in this study. Ammonia and hydrogen sulfide concentrations were measured using a direct-reading instrument which could measure the target gases simultaneously. Gas monitoring was conducted at human breathing height and animal breathing height at three points in each livestock farm. Results: Ammonia concentrations at the broiler hen barns ranged from 3.3 to 12.5 ppm by sampling location and height, but hydrogen sulfide was not detected. In the beef cattle barns, ammonia ranged from 3.1 to 16.3 ppm and low concentrations of hydrogen sulfide were detected at some animal breathing heights. The gas concentrations detected at each livestock farm were significantly higher in the animal breathing zones than in human breathing zones (p<0.0001). Conclusions: We found a difference in gas concentrations between human breathing zones and animal breathing zones. Gas monitoring should be conducted to improve the related environment considering both workers' and animals' health and safety.

Acute Toxicity of Nitrite, Ammonia and Hydrogen Sulfide for Early Developmental Stages of Fenneropenaeus chinensis (대하의 초기생활사에 있어 아질산, 암모니아 및 황화수소의 급성독성)

  • Ji, Jeong-Hun;Gang, Ju-Chan
    • Journal of fish pathology
    • /
    • v.17 no.3
    • /
    • pp.199-205
    • /
    • 2004
  • Effects of nitrite, ammonia and hydrogen sulfide on survival of the early developmental stages of Fenneropenaeus chinensis were determined under continuous flow-through system. The 96hr-$LC_{50}$ values of mysis stage were 18.4 mg/L, 0.69 mg/L and 13.5 $\mu{g}/L$ for nitrite, ammonia and hydrogen sulfide, respectively; 28.3 mg/L, 1.23 mg/L and 20.7 $\mu{g}/L$ for post larva stage and 39.8 mg/L, 1.73 mg/L and 28.5 $\mu{g}/L$ for juvenile stage, respectively. The Fenneropenaeus chinensis sensitivity for the three pollutants was in the order of hydrogen sulfide>ammonia>nitrite. The mysis/post larva, mysis/juvenile and post larva/juvenile ratios of nitrite, ammonia and hydrogen sulfide toxicity were >1.5, >2.0 and <1.5 times, respectively, and mysis were found to be more sensitive to pollutants than juvenile in all cases.

Removal of Hydrogen Sulfide Using Porous Artificial Aggregates Made by Coal Fly-Ash (플라이애쉬를 이용하여 제조된 인공정량골재를 이용한 황화수소의 제거 연구)

  • Kim, Nack-Joo;Cho, Ho-Young;Kim, Seog-Ku;Kang, Sung-Won;Min, Soo-Hong;Lee, Tae-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.407-413
    • /
    • 2006
  • Artificial aggregates made by coal fly ash that is classified as an industrial by-product was tested to oxidize hydrogen sulfide under various testing conditions. For the determination of optimum condition for converting coal fly ash to aggregates, specimens were prepared by varying ratio of fly ash, cement, water content, and foaming agent. These specimens were tested to determine specific gravity, water absorption, and compressive strength. Specimens, which were used for the removal of hydrogen sulfide, were selected based on the measured specific gravity, water absorption, and compressive strength. Tests for hydrogen sulfide removal were performed via batch and column tests. Under the testing conditions used in this study, removal rates of hydrogen sulfide were linearly proportional to amounts of coal fly ash, and further increased when water was added.

($H_2S$ Adsorption Characteristics of $KIO_3$ Impregnated Activated Carbon (($KIO_3$ 첨착활성탄의 황화수소 흡착 성능평가)

  • Kim, Jun-Suk;Kim, Myung-Chan;Kang, Eun-Jin;Kim, Myung-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.72-79
    • /
    • 2003
  • The impregnated activated carbons were prepared by the incipient wetness method with the contents of $KIO_3$ varied from 1.0${\sim}$10 wt% as the impregnation material. The specific surface area and micropore volume of the rice hulls activated carbon were $2,600{\sim}2,800$ $m^2$/g and 1.1${\sim}$1.4 cc/g, respectively. With increasing the contents of impregnation materials, the surface area and micropore volume decreased by 3${\sim}$21%. However, The amounts of hydrogen sulfide adsorbed increased by 2.1${\sim}$2.8 times depending on the impregnation content. The optimum contents of $KIO_3$ were 2.4 wt%. Although the breakthrough time and adsorption capacity of hydrogen sulfide decreased with increasing temperature in the case of the unimpregnated activated carbons, they increased by 1.2${\sim}$ 3.2 times for the case of the impregnated activated carbons. The optimum aspect ratio(L/D) was 1.0 and the adsorption amount of hydrogen sulfide enhanced with increasing the gas flow rate. The regeneration temperature was determined as 400$^{\circ}C$ from the TGA experiment. The adsorption capacity of hydrogen sulfide with the impregnated activated carbon decreased gradually as the regeneration continued. The hydrogen sulfide adsorption amount of the regenerated activated carbon up to 4 times was still higher than that of the unimpregnated activated carbon.

Hydrogen Sulfide Removal of Biogas from Sewage Treatment Plant with Micro-bubble Generation System (마이크로버블 장치를 이용한 하수처리장 바이오가스의 황화수소 제거)

  • Jung, Jae-Ouk;Jung, Yong-Jun
    • Journal of Wetlands Research
    • /
    • v.22 no.4
    • /
    • pp.239-244
    • /
    • 2020
  • Prior to utilization of energy and power generation, the biogas from anaerobic digestion of sewage treatment plant(46,000㎡/d) should be purified particularly hydrogen sulfide among the various kinds of impurities. This study has focused on the methane decreasing rate and the removal of both hydrogen sulfide and carbon dioxide. In the case of partial circulation, 59.7% of methane gas was decreased to 57.4% in spite of oxidation process with micro-bubble. Carbon dioxide was removed from 38% to 32% and 76.1% of hydrogen sulfide was removed where 1,400ppm was introduced to the DIWS system, which indicated that DIWS system can be of use for the hydrogen sulfide removal of biogas from sewage treatment plant.

Performance Evaluation of Manhole Filter to Remove Odor Inside Sewage Pipe -Focused on Removal of Hydrogen sulfide- (하수관거 악취 제거를 위한 맨홀필터 악취제거장치 성능 평가 - 황화수소 제거를 중심으로 -)

  • Kim, Choong-Gon;Lee, Jang-Hown
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.4
    • /
    • pp.45-51
    • /
    • 2018
  • The objective of this study is to evaluate the applicability of a manhole-filter odor eliminator that is installed on a manhole to remove hydrogen sulfide ($H_2S$) contained in the sewage of urban streets; $H_2S$ is the very cause of offensive odor from such sewage. An analysis of the capability of impregnated activated carbon, which is contained in the manhole filter, to adsorb hydrogen sulfide shows that some 99.8% of hydrogen sulfide can be removed. A performance evaluation of the manhole-filter odor eliminator, which was made on Manhole Section 4 known as the representative malodorous manhole section of Seoul, Korea, indicates that more than 97% of hydrogen sulfide ($H_2S$), one of typical malodor-generating substances, can be eliminated. The results and findings of the study as described above suggest that the applicability of the manhole-filter odor eliminator to eliminate offensive odor generated from sewer manholes is satisfactory.

A case of syncope in a villager with hypertrophic cardiomyopathy after hydrogen sulfide exposure by an unauthorized discharge of wastewater

  • Hyeonjun Kim;Seunghyeon Cho;Inho Jung;Sunjin Jung;Won-Ju Park
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.34.1-34.8
    • /
    • 2023
  • Background: Hydrogen sulfide is a toxic substance that humans can be exposed to occupationally, and cases of hydrogen sulfide poisoning of workers in industrial sites are commonly reported. However, there have been no cases of poisoning of the public due to an unauthorized discharge of wastewater, so it is important to describe this incident. Case presentation: In a small village in Jeollanam-do, Republic of Korea, accounts of a terrible stench had been reported. A 26-year-old man who lived and worked in a foul-smelling area was taken to the emergency room with a headache, dizziness, nausea, and repeated syncope. A subsequent police and Ministry of Environment investigation determined that the cause of the stench was the unauthorized discharge of 9 tons of wastewater containing hydrogen sulfide through a stormwater pipe while the villagers were sleeping. The patient had no previous medical history or experience of symptoms. Leukocytes and cardiac markers were elevated, an electrocardiogram indicated biatrial enlargement, left ventricular hypertrophy, and corrected QT interval prolongation. Myocardial hypertrophy was detected on a chest computed tomography scan, and hypertrophic cardiomyopathy was confirmed on echocardiography. After hospitalization, cardiac marker concentrations declined, symptoms improved, and the patient was discharged after 7 days of hospitalization. There was no recurrence of symptoms after discharge. Conclusions: We suspect that previously unrecognized heart disease manifested or was aggravated in this patient due to exposure to hydrogen sulfide. Attention should be paid to the possibility of unauthorized discharge of hydrogen sulfide, etc., in occasional local incidents and damage to public health. In the event of such an accident, it is necessary to have government guidelines in place to investigate health impact and follow-up clinical management of exposed residents.