• Title/Summary/Keyword: Hydro-Generator

Search Result 155, Processing Time 0.042 seconds

A Study for the Shaft Vibration of the Vertical Type Hydro Electric Power Generator (수축형 수차발전기 축진동에 관한 연구(I))

  • 이승원
    • 전기의세계
    • /
    • v.13 no.3
    • /
    • pp.28-37
    • /
    • 1964
  • It is the intention of this thesis to discriminate and investigate the cause of the shaft vibration of the vertical type hydroelectric power generator with respect to electrical, mechanical and hydraulic aspects, and to analyze the vibration which will occure by the each cause investigated above. In order to test the shaft vibration of No.1 generator in Hwachon, Korea new measurement method and measuring equipments were designed. In practice the shaft vibration of the generator was measured by above equipments and analyzed by the discriminative method. Detailed explanation for the designed measurement method and instruments is presented, and the results which I had tested three times for the generator No.1 in Hwachon power plant are added. As a appendix the mechanism and causes of the thrust bearing's wear and remarks for the runner are written.

  • PDF

Analysis for the Operating Characteristics when the Induction Motor is Used as a Generator (유도전동기를 발전기로 사용시 동작 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.2
    • /
    • pp.5-11
    • /
    • 2014
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. The structure and operating characteristics of induction generator is almost identical to induction motor, but the induction generator part is used restrictively from hydropower power and wind power development etc. Recently induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than synchronous speed of induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load such as increaser, total efficiency is decreased. Consequently the quality in compliance with an induction motor parameter applying like that in the generator is a possibility of having the error of some. In this paper, we analyzed that input, output, torque and efficiency of induction machine is different from each other above and below synchronous speed.

Performance Improvement of Cylindrical Turbine Guide Bearings with Pad Leading-Edge Tapers for Vertical Hydro-Power Application: Effects of Taper Angle and Length (패드 선단 테이퍼를 갖는 수력 수직 원통형 터빈 가이드 베어링의 성능향상 - 테이퍼 각도와 길이의 영향)

  • Lee, An Sung;Jang, Sun-Yong;Park, Soo Man
    • Tribology and Lubricants
    • /
    • v.34 no.1
    • /
    • pp.16-22
    • /
    • 2018
  • Cylindrical turbine guide bearings (TGBs) with simple plain pads have conventionally been used in vertical hydro-power turbine-generator applications in order to provide turbine runner shafts with smooth rotation guides and supports. To overcome low-load/low-eccentricity performance drawbacks, such as very low film stiffness and lack of design credibility in the stiffness values themselves, of conventional cylindrical TGBs, the introduction of a rotational-directional leading-edge taper to each partitioned pad, simply pad leading-edge taper, has been found to be very effective in enhancing their design-application availability and usefulness. In this study, we investigate the effects of taper angle and length for given taper heights in detail in order to systematically establish the effectiveness of design on the performance improvement of vertical hydro-power application cylindrical TGBs with pad leading-edge tapers. The analysis results with $4-Pad{\times}1-Row$ cylindrical TGBs show that the lubrication performance of the cylindrical TGBs is optimized with an approximate taper angle ratio of 0.8 and taper length ratio of 0.9. We conclude that the introduction of pad leading-edge tapers along with the optimization of taper designs can be very effective in improving the overall operation reliability of cylindrical TGBs and the rotordynamic characteristics of vertical hydro-power turbine-generator rotor-bearing systems as well, to which the TGBs are applied.

Characteristics Analysis of Generator by Load Variation (부하변동에 따른 발전기 특성해석)

  • Kim, Jong-Gyeum
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.507-510
    • /
    • 2006
  • 본 논문은 신재생에너지의 한 분야로서 청정에너지인 소수력 발전시스템 운영시 수용가 부하의 변동에 따른 발전기의 특성변화를 해석한 것이다. 모의에 사용된 동기발전기-전동기가 부하의 변동에 따라 토크, 속도, 전류 등이 어떤 영향을 받는지 전자계 과도해석 프로그램을 사용하여 나타내었다.

  • PDF

Study on the Failure Case of Potential Transformer for Generator Protection Relay (발전기 보호계전기용 계기용변성기(PT) 손상 사례에 관한 연구)

  • Park, Jin-Yeub;Chin, Soo-Hwan;Park, In-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2065-2066
    • /
    • 2011
  • 기계적에너지를 전기적에너지로 변환하는 발전기를 내 외부 고장으로부터 보호하기 위해 보호계전기가 설치되어 있으며, 이러한 보호계전기의 동작신호 중 하나인 전압신호를 검출하기 위해 발전기와 변압기를 연결하는 모선에 설치된 계기용변성기를 이용한다. 본 논문은 발전기의 보호계전기용 계기용변성기 손상원인에 관한 연구로서, 계기용변성기의 철공진에 이한 손상가능성을 고찰하였고 발전소에 많이 사용되는 G사의 계기용변성기와 손상된 I사의 계기용변성기에 대한 전기적 시험결과를 비교하였으며, 계기용변성기를 직접 절개하여 제작 및 적용특성을 분석하였다. 그 결과 발전기 전압신호 검출용 계기용변성기는 발전기 중성점 접지형태에 관계없이 반드시 Line to Line type을 적용해야 함을 도출했다.

  • PDF

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

Performance Evaluation of the Samcheonpo Small-Hydro Power Plant (삼천포 해양소수력 성능평가)

  • Cho, Hong-Yeon;Cho, Beom-Jun;Kang, Geum-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.617-620
    • /
    • 2007
  • The performance evaluation of the Samcheonpo small-hydropower plant constructed on the October 25th,2006, was carried out focused on the turbine and generator efficiency analysis by using the measurement data. The unreasonable and unrealistic efficiency results are occurred in some periods because of the data variability, uncertainty, and measurement errors and mistakes. Whereas, the big mismatch is the tidal elevation predicted in the design processes. The difference between the measured and estimated tidal elevation is obvious during the low water period. It should be considered and checked in depth on the efficiency analysis of the planned and constructing small-hydro power plants in other coastal areas.

  • PDF

A study on the overhaul method for a Tandem type EDG on Nuclear Power Plant (원자력발전소 Tandem 형 비상디젤발전기의 최적 정비 방안 연구)

  • Han, Sung-Heum;Lim, Woo-Sang;Ha, Che-Wung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2036-2037
    • /
    • 2008
  • An Emergency Diesel Generator (EDG) manufactured by a French company Wartsila SACM, is a tandem type engine, consisted of two 10 cylindered diesel engines on each side. Manual provided by the manufacturer states that engine bearing requires inspection every 15 years. However, it is difficult for an inspector to access through a manhole located in the lower compartment of engine. Furthermore, during a routine or scheduled maintenance, it is not possible to disassemble main engine bearing and crank shaft, and perform inspection. Two methodologies are suggested here to resolve the problem. One method is to lift the engine and partially perform the maintenance service, and the other method is to disassemble the engine completely and to perform maintenance service by the manufacturer. Pros and cons of two methodologies were thoroughly compared.

  • PDF

Fire Hazard Analysis on Alternative AC Diesel Generator Building Newly Built In Nuclear Power Plant Operation (가동중 원자력발전소에 신축된 대체교류 디젤발전기건물 화재위험도분석)

  • Kim, Jeung-Wook;Choi, Jung-Sub;Jeong, Jae-Geun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.222-226
    • /
    • 2011
  • 원자력발전소 화재위험도분석이후 재평가 10년 주기가 도래하기 전에 대체교류 디젤발전기건물이 신축됨에 따라 동 건물에 대한 화재위험도분석이 필요하게 되었다. 본 논문에서는 국내 'A' 원자력발전소 대체교류 디젤발전기건물에 대한 화재위험도분석을 수행하였다. 분석결과 기술기준에 만족하게 설치되었고 안전정지에 미치는 영향이 없으나 설비운영측면에서 보완할 부분이 도출되었다. 본 논문에 적용된 분석방법, 연구결과 등은 향후 가동중 원자력발전소 신축건물 화재위험도분석시 유용하게 활용될 것으로 기대된다.

  • PDF

Modeling of Nuclear Power Plant Steam Generator using Neural Networks (신경회로망을 이용한 원자력발전소 증기발생기의 모델링)

  • 이재기;최진영
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.551-560
    • /
    • 1998
  • This paper presents a neural network model representing complex hydro-thermo-dynamic characteristics of a steam generator in nuclear power plants. The key modeling processes include training data gathering process, analysis of system dynamics and determining of the neural network structure, training process, and the final process for validation of the trained model. In this paper, we suggest a training data gathering method from an unstable steam generator so that the data sufficiently represent the dynamic characteristics of the plant over a wide operating range. In addition, we define the inputs and outputs of neural network model by analyzing the system dimension, relative degree, and inputs/outputs of the plant. Several types of neural networks are applied to the modeling and training process. The trained networks are verified by using a class of test data, and their performances are discussed.