• Title/Summary/Keyword: Hydraulic structure

Search Result 815, Processing Time 0.024 seconds

Hydraulic experiments on change of intervals between submerged structure and breakwater (수중구조물과 방파제 간의 거리변화에 따른 수리 특성 실험)

  • Park, Seung-Hyun;Park, Jin-Ho;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.168-171
    • /
    • 2007
  • The stability of a typical rubble mound breakwater defenced by a submerged structure is investigated using hydraulic experiments. Incident irregular waves are obtained from the Bretschneider-Mistuyasu spectrum. Experiments are carried out for different spacings between two breakwaters (X/d=2-3) and for different relative widths (B/h=0.7-3.0) of the submerged structure. It is observed that a submerged structure of (B/h) of 0.7-3.0 constructed at a seaward distance (X/d) of 2-3 breaks all the incident waves and dissipates energy and breakwater.

  • PDF

Analysis of Flow and Bed Changes by Hydraulic Structure using CCHE2D: Focusing on Gangjeong-Goryeong Weir (수리구조물에 의한 흐름 및 하상변동 연구- 강정고령보를 중심으로 -)

  • Ahn, Jung-Min;Jung, Kang-Young;Shin, Dongseok;Lyu, Siwan
    • Journal of Wetlands Research
    • /
    • v.19 no.2
    • /
    • pp.181-192
    • /
    • 2017
  • Analysis using a numerical model is important to understand the sediment transport mechanism associated with erosion and sedimentation near weirs and other hydraulic structures within riverine systems. The local riverbed change near a hydraulic structure (Gangjeong-Goryong multi-function weir in the Nakdong river) was analyzed in order to examine the effect of hydraulic structures on local bed change. A 2D numerical model (CCHE-2D) was employed to simulate the sedimentation and erosion over a reach (25 km) including the weir. For the calibration and verification of the model, rainfall data from a real event (Typoon 'Ewiniar' in 2006) were used for flow and stage simulation. And the simulated results show a good agreement with the observed data for the whole domain. From the result, it was found that the installation and operation of the weir could aggravate bed changes by typhoon between movable weirs, and which resulted in redistribution of sediment.

Technique for Bridge Bearing Retrofit Using Wedge-Jack (교좌장치 겸용 웨지잭을 이용한 교좌장치 보수공법)

  • 백동명;유문식;임진석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.837-843
    • /
    • 1999
  • A common hydraulic jack using brdige retrofit has a problem of increasing cost and time of construction to construct additionally temporary bent or concrete bracket, in case of insufficiency work space and release hydraulic pressure. To solve the problem, this technique is developed to alternate the bridge bearing in adequate inspection condition. After control maximum lift-height and minimum lift-force of no damage to super structure, the constructive technique is to alternate and repair the bridge bearing using the wedge jack with bridge bearing ability that is no release hydraulic pressure stopper, and able to reuse separable cylinder.

  • PDF

유압식 조향장치 신뢰성 평가 기준개발

  • 김형의;정동수;이용범;이근호;강보식;윤소남;성백주;김도식;조정대
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.11a
    • /
    • pp.87-95
    • /
    • 2000
  • The testing product is the HSU(Hydrostatic Steering Unit) installed in the armored vehicle which has the compact structure of assembly with hydraulic pump, hydraulic motor, and several hydraulic valves. There are no assesment testing code for HSU within a country because the testing code for HUS is not involved in the technical concert from USA. Therefore the testing code is developed by the dynamic analysis of the armored vehicle. By the developed testing code, the test equipment is designed, manufactured, and used to apply the assesment test.

  • PDF

A Novel Direct Instantaneous Pressure Control of Hydraulic Pump System with SR Drive

  • Liang, Jianing;Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.208-210
    • /
    • 2007
  • This paper proposes a novel direct instantaneous pressure control(DIPC) of hydraulic pump system with SR drive. And it has very simple control structure, because it doesn’t use any speed and torque control for adjusting pump pressure. The hysteresis band of pressure and proper switching rules can make the actual pump pressure to be constant with fast dynamic response. Therefore, the proposed DIPC method can control of hydraulic pump pressure steadily with fast dynamic response.

  • PDF

Estimating Hydraulic Properties of Soil from Constriction-pore Size Distribution (수축공극크기분포를 이용한 지반의 수리학적 물성치 산정)

  • Shin, Hosung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.3
    • /
    • pp.27-34
    • /
    • 2022
  • Since water flow in the ground depends on the pore structure composed of soil grains, equations to predict the hydraulic properties based on the grain size have low accuracy. This paper presents a methodology to compute constriction-pore size distribution by Silveria's method and estimate saturated and unsaturated hydraulic properties of soils. Well-graded soil shows a uni-modal pore size distribution, and poor-graded soil does a bimodal distribution. Among theoretical models for saturated hydraulic conductivity using pore size distribution, Marshall model is well-matched with experimental results. Model formulas for soil-water characteristic curves and unsaturated hydraulic conductivity using the pore size distribution are proposed for hydraulic analysis of unsaturated soil. Continuous research is needed to select a model suitable to estimate hydraulic properties by applying the developed model formulas to various soils.

A Study on the Performance Certification of 5,200ton Compression Load Tester (5,200톤 재하 시험장비의 성능 검증에 관한 연구)

  • Kim, Kwang-Young;Choi, Young-Ho;Ham, Young-Bog;Choi, Byung-Oh;Lee, Dong-Ha
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.149-154
    • /
    • 2001
  • In case of high capacity load force as millions of tons, it is difficult to measure the force with load cell. But we can measure and calculate the force with applied pressure and ram area of hydraulic jack. The 5,200 ton compression load tester is composed of thirteen hydraulic jack with 400 ton capacity. This paper explains the method of measuring the vertical compression load and provides characteristics of unit jack, and displacement of upper structure under maximum load condition.

  • PDF

Simulation of Water Hammer Mitigation at Seobyun Pumping Station (서변 가압장에서 수격현상 완화에 대한 연구)

  • Kim, Sang Hyun;Park, Nam Sik;Jung, Bong Seog;Lee, Dong Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.95-104
    • /
    • 1999
  • A simulation of water hammer, introduced by abruptly varied motion of a pumping machine, was performed at a one of typical pumping station in Korea. Impact of hydraulic structure such as check valve, pressure relief valve and air valve in mitigating water hammer effect was estimated gradually. Method of characteristic was employed for the effective calculation of discharge and head. The relationship between various hydraulic structures and flow was properly integrated on the base of the method of characteristic. The methodology in this approach can provide significant contribution in decision making procedure for the design of hydraulic structure at a typical pumping station in Korea.

  • PDF

Hydraulic Model Test and Numerical Analysis of Grass Concrete in River Environment (자연형 호안공법의 그라스콘의 수리모형실험 및 수치해석 연구)

  • Jang, Suk-Hwan;Park, Sung-Bum;Park, Sang-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1244-1248
    • /
    • 2007
  • This study aims at investigating the in situ applying grass concrete system in river environments which widely used nowadays and reviewing the effect and flow resistance for grass concrete structure through the physical experiments by hydraulic model test and developing application method in river bed which has rigid flood resistance. Grass concrete structure has been independently tested under high velocity flow under the super critical condition, as well as sud critical flow measuring velocity and water surface elevation along the cross section. This results shows grass concrete system is also suited to use in aggressive river environments such as repairing a flood damaged embankment that had placed at risk the adjacent drainage channel with vegetation.

  • PDF

A Special Pre-Service-Inspection Using Radiographic Testing(RT) for Brazing Fitting Uused in Aircraft Hydraulic System

  • Kim, Gyu-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.271-281
    • /
    • 2010
  • Brazing fitting which is one of the aircraft hydraulic power system components is widely used for saving weight and achieving higher reliability. Any inherent defects or damage of fitting can cause system failure and/or physical damage of human body due to highly pressurized fluid. Radiographic testing(RT) technique and additional micro-structure investigation on cut-away surfaces have been accomplished to find out some defect-like-inhomogeneity in the fittings. The radiography results showed that some defect-like-inhomogeneity existed inside body. Additional micro-structure investigation on cut-away surface reveals that the inhomogeneity is due to internal voids. In this study, it can be is said that RT technique can be a useful tool for field acceptance test of hydraulic brazing fitting in short time.