• Title/Summary/Keyword: Hydraulic loading

Search Result 346, Processing Time 0.028 seconds

Kinematics and Structural Analysis for Optimization of an Electro-Hydraulic Sliding Deck Systems (전동 유압 슬라이딩 데크 시스템 최적화를 위한 기구학 및 구조해석)

  • Moon, Hyeok-Joo;Ryuh, Beom-Sahng;Oh, Young-Sup;Kim, Man-Jung;Lee, Jung-hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.21-28
    • /
    • 2017
  • Electro-hydraulic sliding deck systems have been developed to reduce the weight for the loading of an agricultural machine. The extension length of the sliding deck was calculated according to the bed's dump angle. The optimum thickness and material were determined using a large and heavy load at acceptable angles. In addition, the degrees of freedom were calculated to obtain the input/output relationship of the system. An equation was derived using a simplified model formula for the extended length of the sliding deck according to the bed's dump angle. Also, the advance length at the maximum and minimum angles of the system was determined using numerical analysis. A down-scaled model of the system was constructed and verified by experiments. The deck was simplified to determine the material and thickness of the sliding deck and for the selection of the two representative materials. The simplified model was tested in deformation tests and stress tests with different thicknesses and materials using a structure analysis program. The analysis results show that ATOS80 is the best among the two materials for reducing the weight of the system.

Evaluation of Swine Wastewater Pretreatment Using Anaerobic Filter (Anaerobic Filter에 의한 양돈폐수의 전처리 특성 평가)

  • Kang, Ho;Moon, Seo-yeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.7
    • /
    • pp.418-425
    • /
    • 2015
  • Anaerobic Filters (AF) packed with porous ceramic floating media were operated at different operational conditions to identify the feasibility of the renewable bioenergy, methane production from swine wastewater and to verify the suitability of effluent from anaerobic filters for the subsequent biological nitrogen and phosphorus removal. Stepwise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) with influent TCOD concentration of 14,000 mg/L were utilized at mesophilic temperature. The maximum methane productivity of 1.74 volume of $CH_4$ per volume of reactor per day (v/v-d) was achieved at an hydraulic retention time (HRT) of 0.5 day (OLR 28 g TVS/L-d). Based on the biogas production, the highest total volatile solids (TVS) removal efficiency of 63% was obtained at an HRT of 3 days (OLR 4.67 g TVS/L-d), however based on the result from the effluent total chemical oxygen demand (TCOD) analysis, the highest TCOD removal efficiency of 75% was achieved. The effluent alkalinity concentration over the range of 2,050~2,980 mg/L as $CaCO_3$ at all operational conditions, could compensate the alkalinity destruction caused by nitrification. The effluent from the anaerobic filter operated under the HRT of 2 days showed the COD/TKN ratio of 15~35 and COD/TP ratio of 38~56. Therefore effluent C/N/P ratio is able to satisfy the optimum COD/TKN ratio of greater than 8.0 and COD/TP ratio of 33 for the subsequent biological nutrient removal.

Effects of Hydraulic Rentention Time on Anaerobic Digestion of the Mixture of Nightsoil and Septic Tank Sludge (소화조(消化槽)의 수리학적(水理學的) 체류시간(滯留時間)이 분뇨(糞尿)와 정화조(淨化槽)슬러지 혼합물(混合物)의 혐기성소화(嫌氣性消化)에 미치는 영향(影響))

  • Lee, Kwang Ho;Yang, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.117-127
    • /
    • 1983
  • An experimental research was performed employing the two stage anaerobic digestion of the mixture of the nightsoil and septic tank sludge to determine the effects of various hydraulic retention time of the digestion on chemical characteristics and treatment effeciency, thus determining the proper retention time. Results of the research are as follows, 1. Volatile-acid decreased as HRT increased. 2. Alklinity and ammonia-N tended to increase as HRT increased as did pH values, however, were observed to be constant at higher HRT values than 15 days. 3. The removal efficiencies of TBOD, TCOD and VS increased as HRT increased. 4. The removal efficiency of volatile solid decreased as VS loading increased. 5. It was observed that the rates of gas production were: 0.33 with HRT of 5 days, 0.58 with HRT of 15 days and $0.57m^3/kg$ VS fed/day with HRT of 25 days respectively. It is believed that the highest rate of gas production was at HRT of 15 days. 6. The sludge settling experiment showed that the minimum settling time required to ensure the desired underflow concentraton was estimated to be 8.6 days.

  • PDF

Application of anaerobic baffled reactor to produce volatile fatty acids by acidification of primary sludge (Anaerobic Baffled Reactor 공정을 이용한 1차 슬러지 산발효에 대한 연구)

  • Kwon, Se Young;Kang, Min Sun;Kim, Se Woon;Shin, Jung-Hun;Choi, Han-Na;Jang, Hoon;Cho, Jin Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.13-23
    • /
    • 2014
  • A lab-scale Anaerobic Baffled Reactor (ABR) was applied to treat a primary sludge taken from a municipal wastewater treatment plant. In this experiment, acidogenic reaction was promoted by operating the ABR with short hydraulic retention time (HRT) to produce sufficient volatile fatty acids (VFA) instead of production of methane. The performance of ABR on the VFA production and total solids reduction was observed with different operating conditions with 2, 4, 6, and 8 days of HRT. Corresponding organic loading rates were 6.7, 3.4, 2.2, and $1.6kgCOD_{cr}/m^3{\cdot}day$. As HRT increased the removal rate of TCOD was also increased (82.5, 84.2, 96.9, and 95.9 % in average for HRT of 2, 4, 6, and 8 days, respectively) because the settlement of solids was enhanced in the baffle by the decrease of upflow velocity. At HRT of 2 days the average concentration of VFA in the effluent was measured at $1,306{\pm}552$ mgCOD/L corresponding to 107 % increment as compared to the VFA concentration in the influent. However, as HRT increased VFA concentraiotn was decreased to $143{\pm}552$ mgCOD/L at HRT of 8 days. The reduction rates of total solids were 12.2, 26.5, 24.8, and 43.0 % for HRT of 2, 4, 6, and 8 days. As HRT increased the hydrolysis of organic particulate matters in the reactor was enhanced due to the increasing of solids retention time in the baffle zone with low upflow velocity in long HRT condition. Consequently, we found that a primary sludge became a good source of VFA production by the application of ABR process with HRT less than 4 days and the 12-26 % of total solids reduction was expected at these conditions.

Effects of Rotational Speed and Hydraulic Residence Time on the Ammonia Removal of a Rotating Biological Contactor (RBC) (회전속도와 수리학적 체류시간이 회전원판식(Rotating Biological Contactor;RBC) 여과조의 암모니아 제거에 미치는 영향)

  • 오승용;조재윤;김종만
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.142-150
    • /
    • 2003
  • Performance of a biological filter, the rotating biological contactor (RBC), is affected by rotational speed and hydraulic residence time (HRT). A RBC with a disc diameter of 62 cm, total surface area of 48.28 $m^2$, volume of 0.34 ㎥, and submergence ratio of 35.4% was tested for the combinations of five rotational speeds (1, 2, 3, 4 & 5 rpm) and three HRT (0.5, 1.0 & 2.0 hr) to find out the maximum removal efficiencies of total ammonia nitrogen (TAN) and nitrite nitrogen of a simulated recirculating aquaculture system. Ammonia loading rate in the system was 25 g of TAN/ ㎥. day. Removal efficiencies were checked when TAN concentrations in the system stabilized for 3 days in each treatment. The concentration of TAN in the system decreased with increasing rotational speed of the RBC up to 4 rpm in all HRT (P<0.05). At the rotational speed of 5 rpm, the efficiencies decreased in all HRT (P<0.05). When the rotational speeds were 1, 2, 3, 4, and 5 rpm, TAN concentrations in the system were 1.35, 0.94, 0.69, 0.66, and 0.76 mg/L at the 0.5 hr HRT, 2.86, 1.18, 0.96, 0.87, and 1.11 mg/L at the 1.0 hr HRT, and 5.30, 2.44, 1.99, 1.77, and 2.01 mg/L at the 2.0 hr HRT, respectively. The TAN removal efficiencies of the RBC at the rotational speeds of 1, 2, 3, 4, and 5 rpm were 32.9, 49.5, 65.1, 72.9, and 62.9% in 0.5 hr HRT,33.1, 74.1, 87.1, 95.8, and 78.5% in 1.0 hr HRT, and 35.5, 76.7, 89.6, 97.0, and 85.5% in 2.0 hr HRT, respectively. TAN removal efficiency of RBC per pass increased with increasing HRT. However, TAN concentration in the system also increased. The best operating condition among the treatments was obtained at the treatment of 0.5 hr HRT and 4 rpm (P<0.05). The TAN concentration was 0.66 mg/L. Concentrations of nitrite nitrogen (NO$_2$$^{[-10]}$ -N) in the system decreased with increasing rotational speed in all HRT while that in the system increased with increasing HRT in all rotational speeds. The ranges of NO$_2$$^{[-10]}$ -N concentrations at HRT of 0.5, 1.0, and 2.0 hr in the system were 0.26~0.32, 0.31~0.56, and 0.43~l.45 mg/L, respectively. The ranges of daily removal rates of TAN in this system were 20.03~23.0 g TAN/㎥ㆍday and those of nitrite nitrogen were 19.65~30.25 g NO$_2$$^{[-10]}$ -N/㎥ㆍday.

Development of the Semi-Crawler Type Mini-Forwarder - Design and Manufacture - (반궤도식 산림작업차 개발(I) - 설계 및 제작 -)

  • Kim, Jae-Hwan;Park, Sang-Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.154-164
    • /
    • 2011
  • This study was conducted to develop the semi-crawler type mini-forwarder that can be operated comfortable small-scale logging operation in the steep terrain and also used at a variety of operations such as the civil work in erosion control and forest-road. Considering the minimum turning radius and the width of forest operation road, the total length, width and loading capacity of the semi-crawler type mini-forwarder is 5,750 mm, 1,900 mm and $2.5m^{3}$, respectively. The maximum engine power is 96ps at 3600 rpm. Selected hydraulic pumps are consists of two main pumps and two sub-main pumps. Main hydraulic pumps are utilized to running motor of the front wheel and rear crawler. Sub-main pumps are utilized to the actuation parts such as steering, crane, out-rigger and dump cylinder. The transmission was adapted as the HST (Hydro-Static Transmission) system. The driving parts are designed and manufactured as the front wheel type and the rear crawler type. The steering type was manufactured as the ackerman type. Driving control parts type was designed and manufactured as driver's seat type of normal cars. It is also attached on auxiliary equipments such as winch, log grapple and out-rigger. The traveling speed of the semi-crawler type mini-forwarder in forest road was 5.3 km/hr to 7.7 km/hr.

Performance Evaluation of Backwash Hydrodynamic Separator Filter for Treatment of Micro Particles (역세척 Hydrodynamic Separator Filter를 이용한 미세입자 제거 특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.694-701
    • /
    • 2012
  • The main purpose of this study is to evaluate of backwash system of hydrodynamic separator filter (HSF) with solar powered submerged pumps. It consists of a photovoltaic solar array, control electronics, battery, and two submersible pump powered by a 12 voltage DC motor. The laboratory scale study on treatable potential of micro particles using backwash HSF that was a combined with perlite filter cartridge and backwash nozzles. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particle sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin partices, silica gel particles, and commercial area manhole sediment particles. HSF was made of acryl resin with 250 mm of diameter filter chamber and overall height of 800 mm. Four case test were performed with different backwashing conditions and determined the SS removal efficiency with various surface loading rates. The operated range of surface loading rate was about 308~$1,250m^3/m^2/day$. It was found that SS removal efficiency of HSF using two submersible pumps improved by about 18% compared with HSF without backwash. Nonpoint control devices with solar water pumping systems would be useful for backwashing the filter in areas with not suppling electricity and reduce filter media exchange cost.

Centralized Controller High-altitude Work Car Elevations Lift Structure Safety Assessment (중앙집중식 컨트롤러 고소작업차의 고소리프트의 구조안정성 평가)

  • Kim, Jun-tae;Lee, Gi-yeong;Lee, Sang-sik;Park, Won-yeop
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • This study was conducted as a post - study on the development of a centralized controller and a hydraulic lift system including structural analysis and remote control for the development of a vertically elevated car. The safety review was carried out through the structural modification of the elevator lift which was developed during the previous research. 3D modeling was performed with Solidworks, and a model of finite element was created through Hypermesh S / W. In addition, the loading environment of the work vehicle for the evaluation is a condition in which the loading amount is 250 kg per position (total, upper, upper, lower, and lower) on the work table, ), The structural analysis was carried out under the condition that the load was 600 kg, and safety was examined in various aspects. As a result, when the allowable load of 250 kg and the excess load of 600 kg are excluded (except Case-11), the stress level is below the yield strength. In the case of Case-11, there is a region exceeding the yield strength at the center support portion of the safety bar at the upper end even after excluding the component which generates the maximum stress, but it does not affect the safety aspect of the whole structure Respectively. Looking at the deflection results, it can be seen that in all cases the maximum deflection occurs in the same table, and the tendency of sagging in both 250 kg and 600 kg is the same.

Nitrogen Removal Characteristics in Two-Sludge System of SBR Type Using Sewage Wastewater of Low C/N Ratio (낮은 C/N 비에서 운영되는 SBR 유형의 Two-Sludge 공정의 질소 제거 특성)

  • Ryu, Hong-Duck;Kim, Hak-In;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In this study, nitrogen removal characteristics of SBR3 process, which is two-sludge system of sequencing batch reactor(SBR) type, were investigated, with comparison of those of SBR1 process, which is conventional SBR process, and SBR2 process, which was designed to enhance denitrification efficiency through step-feeding of wastewater, using domestic wastewater. SBR3 process of two-sludge type can perform external nitrification, on which nitrification occurs in separated reactor, and enhanced denitrification using biosorbed organics. In the results with domestic wastewater, T-N removal efficiency of SBR3 process was better than those of SBR1 and SBR2 processes. It was observed that bigger difference of T-N removal efficiency between SBR3 process and SBR1 & SBR2 processes was showed at low C/N ratio than that at high C/N ratio resulting from more efficient use of organics by biosorption mechanism in denitrification of SBR3 process than those of SBR1 and SBR2 processes. In addition, T-N removal efficiency of SBR3 process according to influent T-N loading rate was better than those of SBR1 and SBR2, even though influent T-N loading rate of SBR3 process was higher than that of SBR1 and SBR2 process resulting from operation of SBR3 process in short hydraulic retention time(HRT) by external nitrification.

Nitrogen Removal in Column Wetlands Packed with Synthetic Fiber Treating Piggery Stormwater (축산단지 강우 유출수 처리를 위한 합성섬유충진 습지의 질소제거에 관한 연구)

  • Cheng, Jing;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.68-75
    • /
    • 2016
  • A set of lab-scale polymer synthetic fiber packed column wetlands composing three columns (CW1, CW2 and CW3) with different hydraulic regimes, recirculation frequencies and pollutant loading rates, were operated in 2012. Synthetic fiber tested as an alternative wetland medium for soil mixture or gravel which has been widely used, has very high pore size and volume, so that clogging opportunity can be greatly avoided. The inflow to the wetland was artificial stormwater. All the wetlands achieved effective removal of TSS (94%~96%), TCOD (68%~73%), TN (35%~58%), TKN (62%~73%) and NH4-N (85%~ 99%). Particularly, it was observed that COD was released from the fiber during one distinct period in all wetlands. This was probably due to the degradation of polymer fiber, and the released organic matters were found to serve as carbon source for denitrification. In addition, with longer retention time and frequent recirculation, lower effluent concentration was observed. With higher pollutant loading rate, higher nitrification and denitrification rates were achieved. However, although organic matters were released from the fiber, the lack of carbon source was still the limiting factor for the system since the release persisted only for 40 days.