• 제목/요약/키워드: Hydraulic gate

검색결과 85건 처리시간 0.032초

유압 구동계 에너지 재생 브레이크를 적용한 자동차 테일게이트 개폐장치에 대한 동특성 해석 (Dynamic Analysis on the Tail Gate System for Vehicle with the Energy Regenerative Brake of Hydraulic Driven Systems)

  • 최순우;허준영
    • 유공압시스템학회논문집
    • /
    • 제7권2호
    • /
    • pp.19-26
    • /
    • 2010
  • The typical trunk lid system for vehicle is composed of a hinge having 4-bar link and gas lifter. Here, the energy regenerative brake of hydraulic driven systems is applied to the tail gate system for vehicle and removed the gas lifter. The new tail gate system is composed of a hydraulic pump by electric motor, a hydraulic motor, four check valves, an accumulator, a relief valve and a directional control valve. The dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, are investigated in both brake action and acceleration action. The capacity selection method of accumulator by mathematical model is based upon trial and error approach and computer simulation by AMEsim software is carried out.

  • PDF

아산만 배수갑문 확장사업에 따른 아산만 해역의 수리특성 변화 검토 (Estimation for Changing of Hydraulic States Caused by Gate Expansion in Asan Bay)

  • 박병준;송현구;송태관;장은철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.337-340
    • /
    • 2008
  • The gate expansion was planed to increase discharge capacity of gate structure at sea dike in Asan Bay. So it was estimated for changing of hydraulic states in Pyeongteak Harbor Zone caused by gate expansion, by 2D and 3D CFD Module. In result, influence of gate expansion was less than tidal current and discharge ratio between old gate and new gate was 4:6.

  • PDF

상부 콘크리트 구조물이 없는 소형 수문 시스템 개발 (The Development of Small Sluice gate systems without Upper Concrete structure)

  • 국정한;김기선
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.4738-4744
    • /
    • 2011
  • 본 연구는 상부에 설치되는 콘크리트 구조물 없이 설치되어 작동하는 새로운 소형 수문 시스템을 제안하였다. 주요 메커니즘은 유압시스템, 수문 상하 이송 메커니즘, 수문 잠금 제어장치, 이물질이 감지되면 수문이 파손되지 않도록 하는 안전장치 등으로 구성하였다. 유압 펌프 및 제어 시스템은 수문 시스템의 위치에서 떨어진 장소에 설치하여 상부 구조물을 제거할 수 있도록 하여 제어 하였다. 수문 인양 장치는 유압 액추에이터가 달린 래크와 피니언이 측면에 설치되어 작동되며 그 결과 제품의 원가 절감, 작동시 안전성 확보 및 제품의 컴팩트화를 구현하였다.

전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구 (Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

표층수의 월류를 통한 소수력빌전소 수차터빈측의 유동안정화 연구 (Studies on the flow stabilization around the turbine suction with utilizing the surface water overflow at small-hydraulic power plant)

  • 이성명;김철환;유근종;김원석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.165.2-165.2
    • /
    • 2011
  • Flow with suction to water turbine must be in stable state at small hydraulic power plant. But because of water level fluctuation and water gate effect according to irregular supply of cooling water, it would happen to produce bubble and vortex and finally lead to problems in power-plant system. With utilizing the concept design of double size gate, surface water overflowed the overhead of gate for stable flow at suction. We developed the overflow condition and analyzed the design factor with existed one such as water level(overflow amount) and overhead of water gate(overflow figure). Flow test and CFD simulation say that flow have stable state around suction and 20% of wave reduction effect at surface layer after surface water overflow.

  • PDF

VORTEX STRUCTURE IN THE SCOUR HOLE BY GATE OPENING OF HYDRAULIC STRUCTURE

  • Kim, Jin-Hong;Choe, Jae-Wan
    • Water Engineering Research
    • /
    • 제1권1호
    • /
    • pp.83-92
    • /
    • 2000
  • Jet flow can occur by gate opening at downstream of a hydraulic structure such as weir of drainage gate. If the stream bed is not hard or the bed protection is not sufficient, vortex erosion occurs and a resulting scour hole will be formed due to the high shear stress of the jet flow. Once the scour hole is formed, a vortex occurs in ti and this vortex causes additional erosion. If this erosion continues and reaches to the hydraulic structure, it can undermine the bottom of the hydraulic structure and this will lead to failure of the structure itself. Thus, it is necessary to define the physical features of the vortex structure in the scour hole for the design of the bed protection. This study presents the turbulent vortex structure in the scour hole by the gate opening of the hydraulic structure. Characteristics of vortex motion, circulation, vortex scale and vortex were analyzed through experiments. Experimental results of the vortex velocity were compared with theoretical ones. From these, circulation and vortex scale were obtained with known values of inflow depth, inflow velocity and scale of scour hole

  • PDF

수리모형실험과 FLOW-3D를 이용한 배수갑문 통수능력 검토 (Estimation of Gate Discharge Capacity by Physical Model Test and FLOW-3D)

  • 박병준;이상화
    • 한국해안·해양공학회논문집
    • /
    • 제20권2호
    • /
    • pp.168-175
    • /
    • 2008
  • 군장 국가산업단지(장항지구) 조성공사 후 단지를 가로지르는 솔리천 하구에 새로 건설될 배수갑문 설계안에 대해 축척모형을 제작하고 현장과 동일한 수리조건을 적용한 수리모형실험을 수행하여 통수능력을 검토함과 동시에 결과의 신뢰도 확보를 위해 상용 3차원 전산유체역학 코드인 FLOW-3D를 이용하여 수치모의를 실시하였다. 수리모형실험과 수치모의에서는 얻어진 통수능은 유사한 결과를 보여주었다.

컴플렉스법에 의한 유압시스템의 최적 설계 (Optimal Design of Hydraulic System Using the Complex Method)

  • 이성래;이용범;박종호
    • 유공압시스템학회논문집
    • /
    • 제1권4호
    • /
    • pp.1-8
    • /
    • 2004
  • The optimum design parameters of several hydraulic systems are obtained using the complex method that is one kind of constrained direct search method. First, the parameters of lead-lag controller of the direct drive servovalve is designed using the complex method to satisfy the steady-state error requirement. Second, the optimum locating point of hydraulic cylinder Is determined to minimize the cylinder force in the operation range of rotational sluice gate. For the third application case, the optimum piston area of hydraulic cylinder is determined to minimize the man power to elevate the manually operated sluice gate.

  • PDF

수리모형 실험에 의한 배수갑문 원호형 문비의 하부형상에 대한 진동현상 연구 (Study on Self- excited Vibration of Radial Gate in Estuary Sulices due to Bottom Shape by Hydraulic Model Tests)

  • 이성행
    • 한국관개배수논문집
    • /
    • 제3권1호
    • /
    • pp.10-19
    • /
    • 1996
  • A hydraulic model test was peformed for radial gate in estuary sulices to find out a proper bottom shape of gate which minimize the amplitudes of vibration. Firstly natural frequencies ore measured, and the results were compared with the numerical analysi

  • PDF