• Title/Summary/Keyword: Hydraulic failure

Search Result 296, Processing Time 0.031 seconds

Impacts of Rainfall Events and Distribution on Unsaturated Soil Slope Analysis (불포화 토사사면 해석에 대한 강우사상과 분포의 영향)

  • Kim, Jae-Hong;Kim, Ho-Kyum;Kim, Byeongsu;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.1
    • /
    • pp.35-43
    • /
    • 2016
  • The time distribution of rainfall is one of the most important considerations for evaluating soil slope stability. In order to study the rainfall-induced slope failure, the rainfall pattern has generally been assumed as uniform rainfall intensity for rainfall duration. However, it should be noted that the time distribution of the design rainfall method has a significant effect on the soil slope instability. The study implemented Mononobe, Huff, and uniform method as three types of time distribution method of the design rainfall to estimate the factor of safety of soil slopes by rainfall duration. As a result, the difference of soil suction and unsaturated hydraulic properties in a soil by rainfall pattern was found through the application of an appropriate time distribution method to numerical simulation for rainfall-induced slope stability.

An Experimental Study on the Strength of the Frame consisting of Concrete Filled Steel Tubular Column-H Beam under Alternately Repeated Horizontal Loading (반복하중을 받는 콘크리트충전 강관기둥-H형강보 골조의 강도에 관한 실험적 연구 -접합부 보강형식과 콘크리트충전에 따른 효과-)

  • Lee, Seong Do;Kim, Pil Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.641-655
    • /
    • 1998
  • It researched several jointing-methods of frame consisting of a concrete-filled steel tubular column and H-shaped beam. These beam-to-column connections is parameters to following: columns of square shape pipe infilled with or without concrete, joints assembled two types of diaphragm, outside-type and through-type. And it is testing that cyclically lateral loadings used hydraulic ram. In testing. we'll be on purposed to estimate the hysteretic behavior, strength and stiffness, energy absorption capacity, deformation capacity and failure configuration of each specimen. It is concluded that the frame specimens with outside-type are more stable and exhibit more energy absorption capacity compared with the through-type, in column of filled with concrete.

  • PDF

Measurement of rock fracture toughness under mode I, II & mixed-mode conditions by using disc-typed specimens (인장, 전단 및 혼합모드에서 디스크 시험편을 이용한 암석의 파괴인성 측정에 관한 연구)

  • 장수호;이정인
    • Tunnel and Underground Space
    • /
    • v.9 no.4
    • /
    • pp.315-327
    • /
    • 1999
  • Rock fracture mechanics has been widely applied to blasting, hydraulic fracturing, rock slope and many other practical problems in rock engineering. But a measuring method for the fracture toughness of rock, one of the mort important parameters in fracture mechanics as an intrinsic property of rock, has not been yet well established. To obtain mode I rock fracture toughness, the more favorable disc-typed specimens such as CCNBD, SCB, chevron-notched SCB and BDT were used in this study. Rock fracture toughness under mixed-mode and mode II conditions was measured by using the STCA applied to the CCNBD specimen. Size effects such as specimen thickness, diameter and notch length on fracture toughness were investigated. From the mixed-mode results, fracture envelops were obtained by applying various regression curves. The mixed-mode results were also compared with three mixed-mode failure criteria. In each fracture toughness test, acoustic emission was measured to get the data for determining the load levels of different crack propagation patterns.

  • PDF

Study for Examples of Fire Including Friction with Automotive Clutch, Manual Transmission and Tire System (자동차 클러치, 수동변속기, 타이어 시스템의 마찰에 관련된 화재사례 연구)

  • Lee, Il Kwon;Moon, Hak Hoon;Kim, Jin Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.49-53
    • /
    • 2015
  • The purpose of this paper is to study and analyze the failure examples for fire by friction on clutch, manual transmission and tire system in a car. In the first example, the driver took the pedal with foot to act the clutch. But the clutch disk did not return from flywheel by leakage of clutch hydraulic line. The heat was produced between clutch disk and flywheel by surface contacting. As a result, it was produced the fire by oil sludge sticked with transmission. In the second example, the transmission system was operated to transfer power of engine by contacting with gear and gear. But, as if the oil of transmission was caused the oil insufficiency because of leaking by crack of transmission case, it found the fact that was produced the fire by deposit material on transmission case. In the third example, when the car's driver continuously pushed an accelerator pedal for escaping from dry pit, the tire took the heat by the friction force between tire and surface of road. As a result, it became the direct cause for the fire. Therefore the driver must manage not to produce the fire with friction parts by heating during running.

The effect of mortar type and joint thickness on mechanical properties of conventional masonry walls

  • Zengin, Basak;Toydemir, Burak;Ulukaya, Serhan;Oktay, Didem;Yuzer, Nabi;Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • v.67 no.6
    • /
    • pp.579-585
    • /
    • 2018
  • Masonry walls are of a complex (anisotropic) structure in terms of their mechanical properties. The mechanical properties of the walls are affected by the properties of the materials used in wall construction, joint thickness and the type of masonry bond. The carried-out studies, particularly in the seismic zones, have revealed that the most of the conventional masonry walls were constructed without considering any engineering approach. Along with that, large-scale damages were detected on such structural elements after major earthquake(s), and such damages were commonly occurred at the brick-joint interfaces. The aim of this study was to investigate the effect of joint thickness and also type of mortar on the mechanical behavior of the masonry walls. For this aim, the brick masonry walls were constructed through examination of both the literature and the conventional masonry walls. In the construction process, a single-type of brick was combined with two different types of mortar: cement mortar and hydraulic lime mortar. Three different joint thicknesses were used for each mortar type; thus, a total of six masonry walls were constructed in the laboratory. The mechanical properties of brick and mortars, and also of the constructed walls were determined. As a conclusion, it can be stated that the failure mechanism of the brick masonry walls differed due to the mechanical properties of the mortars. The use of bed joint thickness not less than 20 mm is recommended in construction of conventional masonry walls in order to maintain the act of brick in conjunction with mortar under load.

A Study on Basic Properties of the Reinforced-roadbed Material Using Water Quenched Blast Furnace Slag (수재슬래그를 이용한 강화노반재료의 기초적 특성 연구)

  • 이선복;윤지선
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.103-110
    • /
    • 2003
  • The development of reinforced-roadbed material in substitute for existing roadbed is necessary to protect its failure from the dynamic stress and vibration caused by the traveling of the high-speed and heavy trains. The water quenched blast furnace slag having potential hydraulic reactivity is one of the materials in substitute for soil reinforced-roadbed. We carried out the study of basic properties of roadbed material using Portland cement and CSA(calcium sulphoaluminate) as the activator for the evaluation of its application. As the result of the strength test, this material satisfied design criterion for reinforced-roadbed. Optimum mixing ratio of this reinforced-roadbed material was 15 ~ 17.5 percent of cement and 2.5 percent of CSA by weight of the blast furnace slag. Especially, as permeability is above $10^{-3}$cm/sec, this material proved to have functions of both reinforced roadbed and drainage layer.

An Experimental Study on Suppression of Cavity Development by Enlargement of Base Plate of Box-Culvert Installed at River Levee (하천제방 배수통문의 저판확폭을 통한 공동발생 억제기법 연구)

  • Kim, Jin-Man;Choi, Bong-Hyuck;Lee, Dae-Young;Jin, Young-Ji
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2011
  • Generally, the Box-Culvert in levee is destroyed by various reasons. Especially when Box-Culvert is installed over the pile foundation in soft ground, the failure occurrs for 1) the weakness of compaction in Box-Culvert side by the differential settlement between outer ground and inner soil prism, 2) hydraulic fracturing and disturbance of Box-Culvert side soil by the repeated acting of seepage pressure at flood time. Also the side of Box-Culvert is difficult to compact and the shear resistance is reduced by more than 1/3 for the reduction of friction caused by the difference of material property. In this study, a series of model tests are conducted for the analysis of the development mechanism of outer ground and inner soil prism by the differential settlement using the pile foundation in soft ground, and cavity suppressed technique is suggested by the analysis of base plate enlargement effect.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

A Study on the Problem of Pressure and Flow Rate by Prescriptive Code Based Design of Fire Sprinkler System (사양위주 스프링클러설비 설계의 압력과 유량의 문제점에 대한 고찰)

  • Jeong, Keesin;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.14-19
    • /
    • 2013
  • National Fire Safety Code 103 regulates that all operating sprinkler in design area must be discharged 1 bar or more pressure and release 80 lpm or more flow rate as minimum criteria. NFSC103 also provides that the number of operating sprinkler in design area is 10, 20, 30 according to the building classification and the total flow rate is 800, 1,600, 2,400 lpm depending on 80 lpm per sprinkler. If sprinkler system is designed as above provisions, the pressure and the flow rate accordingly become smaller than the minimum criteria about 50 % sprinklers. It results in serious consequence that the purpose of sprinkler system as initial fire reaction equipment is failure. In order to solve these problems, It is desirable that Performance-based fire protection design, hydraulic calculation, is carried out to all sprinkler system.

A Study on Simulation of Dam-break Wave Using Two-dimensional Finite Volume Model (2차원 유한체적모형을 이용한 댐 붕괴파 모의에 관한 연구)

  • Jeong, Woo-Chang;Park, Young-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.3
    • /
    • pp.249-262
    • /
    • 2011
  • In this study, in order to reduce the numerical oscillation due to the unbalance between source and flux terms as the HLLC scheme is applied to the flow analysis on the irregular bed topography, a unstructured finite volume model based on the well-balanced HLLC scheme and the shallow water equations is developed and applied to problems of dam-break waves. The well-balanced HLLC scheme considers directly the gradient of bed topography as the flux terms is calculated. This scheme provides the good numerical balance between the source and flux terms in the case of the application to the steady-state transcritical flow. To verify the numerical model developed in this study, it is applied to three cases of hydraulic model experiments and a field case study of Mapasset dam failure (France). As a result of the verification, the predicted numerical results agree relatively well with available laboratory and field measurements. The model provides slightly more accurate results compared with the existing models.