• Title/Summary/Keyword: Hydraulic Machine

Search Result 337, Processing Time 0.033 seconds

Effect of Basis Weight of Handsheet and Machine Made Sheet on Formation (평량에 따른 수초지와 기계지의 지합 특성)

  • Youn, Hye-Jung;Chin, Seong-Min
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.4 s.117
    • /
    • pp.24-30
    • /
    • 2006
  • Formation which is an indicator of nonuniformity in fiber distribution is concerned with small scale variation in roughness, optical properties, print density, and so on. This study evaluated the formation of sheets which were made usning handsheet former and paper-machine with hydraulic headbox. Optical method and ${\beta}-ray$ method were used for formation test. The fiber type, freeness and basis weight of sheet were considered as variables. The formation of handsheet was affected by fiber type and freeness, and floe size distribution was influenced by basis weight. For machine made sheet, its formation seemed to be dependent on the hydraulic forces in headbox and former. When two formation test methods were compared, there was the highest relationship between optical formation index and normalized standard deviation from ${\beta}-ray$ method.

Injection Unit Precision Inspection according to Control Method of Injection Molding Machine (사출성형기의 제어방식에 따른 사출장치 정밀도 검사)

  • Jung, Hyun-Suk;Yoo, Joong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.414-419
    • /
    • 2016
  • A study of a precision test according to the control method of an injection molding machine was carried out. The effects of the screw stroke, holding pressure, melt temperature on both the hydraulic and electric injection molding machine were examined. In addition, hypothesis testing was performed to determine the deviation of the data obtained in the experiments. The conclusions obtained in this study were as follows. Significant deviations in the screw stroke, melt temperature and holding pressure occurred in that order. The hydraulic type showed significantly more variation between the products compared to the electric type. In addition, using a mini tab from the statistics program, a hypothesis was proposed and the P value of the injection stroke, holding pressure, melting temperature injection stroke and melting temperature had adopted a null hypothesis ($H_0$). The holding pressure, which showed mutual differences, adopted an alternative hypothesis ($H_1$).

The effects of Load of Hydraulic Oil on Hydraulic Mechanism (유압유 부하가 유압기계에 미치는 영향)

  • 박주석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.72-74
    • /
    • 1998
  • The adaptive skill of the human operator is now being simulated and reproduced by computer that have become more powerful and less expensive. This paper is concerned with an investigation of the effects of dynamic load of hydraulic oil on pressures with three different circuit(meter-in, meter-out and bleed-off). The experimental results showed that pressures increase with an increase in dynamic load in bleed-off circuit, but there is no variation of pressure in meter-in and meter-out circuits.

  • PDF

Development of a Large Force Standard Machine with Built-in Force Transducers (내장형 힘 변환기를 이용한 대용량 힘 표준기 개발)

  • Gang, Dae-Im;Lee, Jeong-Tae;Song, Hu-Geun;Kim, Eom-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.667-675
    • /
    • 2000
  • Force measuring devices should be calibrated to guarantee their test results. In order to establish the force standards in Korea, deadweight machines of 5 kN, 20 kN, 100 kN and 500 kN capacity and a hydraulic force standard machine of 2 MN capacity were installed at the Korea Research Institute of Standards and Science(KRISS). As heavy industries in Korea have been developed, we should measure large forces over 2 MN capacity precisely in industries. We developed a 10 MN force standard machine with built-in force transducers which is more compact and cheaper than hydraulic force standard machines which have been widely used as large force standards in most national metrology laboratories. Test results reveal that the relative expanded uncertainty of the force machine is less than 4.1 $\times$ 10-4 in the range of 1 MN-4.5 MN.

Application of the machine learning technique for the development of a condensation heat transfer model for a passive containment cooling system

  • Lee, Dong Hyun;Yoo, Jee Min;Kim, Hui Yung;Hong, Dong Jin;Yun, Byong Jo;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2297-2310
    • /
    • 2022
  • A condensation heat transfer model is essential to accurately predict the performance of the passive containment cooling system (PCCS) during an accident in an advanced light water reactor. However, most of existing models tend to predict condensation heat transfer very well for a specific range of thermal-hydraulic conditions. In this study, a new correlation for condensation heat transfer coefficient (HTC) is presented using machine learning technique. To secure sufficient training data, a large number of pseudo data were produced by using ten existing condensation models. Then, a neural network model was developed, consisting of a fully connected layer and a convolutional neural network (CNN) algorithm, DenseNet. Based on the hold-out cross-validation, the neural network was trained and validated against the pseudo data. Thereafter, it was evaluated using the experimental data, which were not used for training. The machine learning model predicted better results than the existing models. It was also confirmed through a parametric study that the machine learning model presents continuous and physical HTCs for various thermal-hydraulic conditions. By reflecting the effects of individual variables obtained from the parametric analysis, a new correlation was proposed. It yielded better results for almost all experimental conditions than the ten existing models.

Image Detection System for Leakage Regions of Hydraulic Fluid in Faring Press Machine (단조프레스기의 유압유 누유영역 영상 감지 시스템)

  • Bae, Sung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.11
    • /
    • pp.1557-1562
    • /
    • 2009
  • In the hydraulic room of a forging press machine, a system which can detect and prevent risks at its early stage is needed because there may be a leakage due to the damage of the connection parts of the piping which can endanger human life and mechanical damage. In this paper, the system to automatically recognize a leakage of hydraulic fluid in terms of using the pan/tilt camera from a remote place is implemented. It finds the bounding boxes which are recognized with object regions in the process of labeling and detects the proper leakage regions of hydraulic fluid with the ratios of width and height of the bounding boxes and compactness of the leakage shape. Also, it performs noise removal and calibration for transition and rotation of image as a preprocessing process. The experimental results show that the proposed system has been verified to detect the leakage regions accurately in various sources of light.

  • PDF

Image Detection System for leakage regions of Hydraulic Fluid in Foring Press Machine (단조프레스기의 유압유 누유 영역 영상 감지 시스템)

  • Lee, Kyeong-Hwan;Bae, Sung-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.35-39
    • /
    • 2009
  • In the hydraulic room of a forging press machine, a system which can detect and prevent risks at its early stage is needed because there may be a leakage due to the damage of the connection parts of the piping which can endanger human life and mechanical damage. In this paper, the system to automatically recognize a leakage of hydraulic fluid by the pan/tilt camera from a remote place is implemented. It finds the Minimum Boundary Rectangles(MBR) which are recognized with candidate leakage regions in the process of labeling and detects the proper leakage regions of hydraulic fluid with the width and height of MBRs and the area ratios of the MBRs and the candidate leakage regions. The experimental results show that the proposed system has been verified to detect the leakage regions accurately in various light conditions.

  • PDF

Vibro-acoustic Design and Development of a Low-noise Hydraulic Breaker (저소음형 유압 브레이커의 음향-진동 설계 및 개발)

  • 이종화;이정권;박성하;하태광;임종혁
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.5
    • /
    • pp.148-155
    • /
    • 2001
  • Hydraulic breaker is currently used for many civil engineering areas owing to the ease of changing the tooling mechanism. However, due to a high noise level, it has been one of notorious sources of environmental noise and the prevailing environmental concerns force the manufacturers to reduce the radiated noise levee during operations. To comply with such concerns, the present study is focused on designing and developing a low-noise hydraulic breaker For this purpose, sound sources are identified and relative contributions are rated. Acoustic enclosure. sealing systems, and low-nolle type chisel have been developed and applied to the actual machine. As a result, the radiated noise from the developed low-noose hydraulic breaker is reduced more than 13 dB(A) In comparison with the conventional hydraulic bleaker.

  • PDF

Pressure Ripple Reduction of Hydraulic Pump-Motor in HST (HST용 유압폄프.모터의 압력맥동 저감 특성)

    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.117-123
    • /
    • 2003
  • This paper deals with pressure ripple and noise reduction characteristics for a hydrostatic transmission(HST) consisting of a variable axial piston pump connected in an open loop to a fixed displacement axial piston motor. Pressure ripples in HST is major source of vibration, which can lead to fatigue failure of components and cause noise. In order to reduce the pressure ripple, an annular tube type hydraulic filter proposes to absorb pressure ripples with the high frequencies components to achieve better noise attenuation in HST. The basic principle tube is applied to propagation of pressure wave, reflection, absorption in cross section of discontinuity and resonance in the hydraulic pipeline. It is experimently confirmed that a hydraulic filter is absorbed to be about 30∼40dB of pressure ripple with high frequencies. These results will assist in modeling and design of noise reduction in hydraulic control systems, and here, should provide a means of designing a quieter HST.

  • PDF