• 제목/요약/키워드: Hydraulic Cycling Test

검색결과 7건 처리시간 0.024초

70 MPa용 Type 3 수소 복합용기의 상온수압반복 거동에 관한 연구 (A Study on the Behavior of Ambient Hydraulic Cycling Test for 70 MPa Type3 Hydrogen Composite Cylinder)

  • 조성민;김창종;김영규
    • 한국가스학회지
    • /
    • 제16권1호
    • /
    • pp.46-50
    • /
    • 2012
  • 본 연구에서는 수압반복시험 장비를 이용하여 70 MPa용 Type 3의 수소복합용기에 대한 거동과 용기내부에 압력이 가해졌을 때 용기 거동을 유한요소법으로 해석하였다. 그 결과, 안전성과 경량성으로 주목받고 있는 Type3 수소용기는 실린더부에서 파열이 먼저 시작되었으며, 유한요소해석 결과에서도 동일한 양상을 확인하였다. 시험결과로 용기내부에 압력이 가해짐에 따라 실린더 몸통부가 부풀어 올라 돔너클과 실린더 몸통부가 가장 취약함을 알 수 있었다.

상온 수압반복시험 시 Type 3 복합재용기 내 공기층의 온도변화 (Temperature Variations of Air Pocket in Type-3 Composite Vessel during Ambient Hydraulic Cycling Test)

  • 조성민;김광석;김창종;유근준;이연재;조윤성;류성기
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.120-125
    • /
    • 2015
  • This research aims to increase the reliability and reproducibility of the ambient cycling test by properly making corrections to the test procedure. The vessel (106 L) is initially filled with 70 L of water and horizontally placed on a balance. The pressure range inside the vessel varies from 2.5 to 25.9 MPa at the frequency of 6 cycles per minute. After reviewing the results, there was a temperature difference of approximately $10^{\circ}C$ between the air pocket and the water, and the upper part of the liner faced a repeated temperature change of $40^{\circ}C$. It is possible for the aluminum liner of the composite vessel to be damaged by such a sharp change in temperature. Additionally, as a result, no pass having anything to do with the purpose of the test would occur. Therefore, it is suggested that the air pocket be completely removed.

수소복합재용기 TYPE3에 대한 수압반복 거동 평가 (Evaluation on Behavior of Hydraulic Cycling Test for Type3 Hydrogen Composite Cylinder)

  • 조성민;이승훈;류근준;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.98.2-98.2
    • /
    • 2011
  • 지구 온난화의 원인이 되는 이산화탄소를 저감하며 유해한 배기가스를 배출하지 않는 수소연료전지자동차(FCV)에 대한 관심이 높아지고 있다. 한국가스안전공사에서 현재 구축하고 있는 평가장비는 이러한 수소연료전지자동차용으로 사용되는 고압용기의 수압반복시험 및 밸브류로 구성된 고압수소저장시스템의 단품 및 시스템 평가를 통한 안전신뢰성 검증을 목적으로 하고 있다. 현재 수소연료전지자동차는 차량이나 부품의 시험 방법에 대한 통일된 기준/표준/시험법이 아직 완전하게 정비되어 있지 않고, 시장에서의 도입 제도, 기준 등이 만들어지고 있는 현실이다. 또한 연료로 수소를 사용하는 도입단계에 있기 때문에, 수소용기가 반복압력변동에 따라 어떤 거동을 나타내는지에 대한 실험관련 연구가 미진한 상태이다. 따라서 수소연료전지자동차용 고압수소저장시스템에 대한 내구성, 안전성 확보를 위하여 수소연료전지자동차에서 중요한 부품인 용기에 대한 반복피로시험이 필요하다. 특히 복합재 용기 분야에서 Type3용기에 대한 높은 안전성과 내구성이 보고되고 있지만 실질적으로 얼마나 다른 용기에 비해 높은 성능을 가지고 있는지 국내에서는 체계적으로 검증된바 없다. 따라서 구축된 수압반복 장비를 이용하여 Type3 용기에 대한 수압반복시험을 실시하였으며, 이를 통해 수소용기의 거동을 확인하고자 한다.

  • PDF

An Investigation into the PID Control for the Electro- Hydraulic Servo System of Skin Pass Mill

  • Lee, Jae-Cheon;Kim, Seong-Jin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권4호
    • /
    • pp.47-53
    • /
    • 2001
  • This study is to investigate the problem of the SPM(Skin Pass Mil7) system which is a finishing treatment of steel sheet. and to develop a PID control scheme to minimize process instability. An electrohydraulic servo system with conventional proportional controller used to regulate the force on the strip works inadequately to yield very undesirable transient responses at the moments welding parts of the strip conte into and pass through the rolls. Both linearized and nonlinear models of a typical SPM system ware simulated first by using Simulink. Then Ziegler-Nichols ultimate cycling method was used for an initial reference guide to tune PID gains, and further fine tuning was performed to get desirable response. The test result in the plant show that proposed PID control scheme successfully improves the process instability in a SPM system.

  • PDF

조사시험용 압력용기의 조립 및 시험 (The Assembly and Test of Pressure Vessel for Irradiation)

  • 박국남;이종민;윤영중;전형길;안성호;이기홍;김영기;케네디
    • 대한기계학회논문집A
    • /
    • 제33권2호
    • /
    • pp.179-184
    • /
    • 2009
  • The Fuel Test Loop(FTL) which is capable of an irradiation testing under a similar operating condition to those of PWR(Pressurized Water Reactor) and CANDU(CANadian Deuterium Uranium reactor) nuclear power plants has been developed and installed in HANARO, KAERI(Korea Atomic Energy Research Institute). It consists of In-Pile Section(IPS) and Out-of Pile System(OPS). The IPS, which is located inside the pool is divided into 3-parts; the in-pool pipes, the IVA(IPS Vessel Assembly) and the support structures. The test fuel is loaded inside a double wall, inner pressure vessel and outer pressure vessel, to keep the functionality of the reactor coolant pressure boundary. The IVA is manufactured by local company and the functional test and verification were done through pressure drop, vibration, hydraulic and leakage tests. The brazing technique for the instrument lines has been checked for its functionality and performance. An IVA has been manufactured by local technique and have finally tested under high temperature and high pressure. The IVA and piping did not experience leakage, as we have checked the piping, flanges, assembly parts. We have obtained good data during the three cycle test which includes a pressure test, pressure and temperature cycling, and constant temperature.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

상향류 활성탄 생물막 공정을 이용한 정체 수역 수질 개선 및 공정 내 미생물 군집 해석 (Water Quality Improvement of Stagnant Water using an Upflow Activated Carbon Biofilm Process and Microbial Community Analysis)

  • 오유미;이재호;박정진;최기충;박태주;이태호
    • 대한환경공학회지
    • /
    • 제32권1호
    • /
    • pp.23-32
    • /
    • 2010
  • 정체수역에서는 자연적 흐름의 차단으로 인해 자정능력이 떨어지며, 영양염류의 축적으로 인해 부영양화와 같은 문제점이 발생한다. 또한 비점오염물질의 유입은 정체수역 내 난분해성 물질을 증가시킨다. 본 연구에서는 정체수역의 수질개선을 위해 무산소조, 호기1조, 호기2조로 구성된 장치형 상향류 활성탄 생물막 반응기를 도입하여 정체수의 연속적 순환에 따른 오염물질 농도의 변화를 모니터링 하였다. 정체수역을 모사하기 위하여 $2m^3$의 저장탱크에 유원지의 호소수를 저장하였으며, 수질개선을 위한 최적 유입 유량을 산출하기 위하여 HRT가 6 hr, 4 hr, 2 hr 가 되도록 호소수의 유입 유량을 변화시켰다. 이 가운데 HRT 4 hr에서 SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, TP의 제거 효율이 각각 69.8, 83.0, 91.3, 74.1, 74.7, 88.9%로 가장 좋은 수질 개선 효과를 얻을 수 있었다. 이에 HRT를 4 hr로 고정하고 골프장 연못수를 운전했을 때 SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$ TN, TP의 제거 효율이 각각 78.5, 78.0, 80.2, 74.9, 55.6, 97.5% 달성되었다. 각 조건에서의 미생물 군집 변화를 PCR-DGGE를 사용하여 분석 결과, 유입수를 골프장 연못수로 교체함에 따라 미생물 군집에 변화가 나타났다. 또한 FISH에 의해 유입 유량 변화에 따른 질산화 미생물량의 변화를 관찰한 결과, HRT 4 hr의 조건에서 질산화 미생물이 가장 우점화됨을 알 수 있었다. 미생물량 및 INT-DHA를 이용한 미생물 활성도 실험 결과, HRT를 낮게 유지하였을 때에도 감소되지 않았다. 따라서 상향류 활성탄 생물막 공정을 정체 수역의 효과적인 수질 개선에 충분히 적용할 수 있을 것으로 기대한다.