Optical Diagnostics of Nanopowder Processed in Liquid Plasmas

  • Bratescu, M.A.;Saito, N.;Takai, O.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.17-18
    • /
    • 2011
  • Plasma in liquid phase has attracted great attention in the last few years by the wide domain of applications in material processing, decomposition of organic and inorganic chemical compounds and sterilization of water. The plasma in liquid is characterized by three main regions which interact each - other during the plasma operation: the liquid phase, which supply the plasma gas phase with various chemical compounds and ions, the plasma in the gas phase at atmospheric pressure and the interface between these two regions. The most complex region, but extremely interesting from the fundamental, chemical and physical processes which occur here, is the boundary between the liquid phase and the plasma gas phase. In our laboratory, plasma in liquid which behaves as a glow discharge type, is generated by using a bipolar pulsed power supply, with variable pulse width, in the range of 0.5~10 ${\mu}s$ and 10 to 30 kHz repetition rate. Plasma in water and other different solutions was characterized by electrical and optical measurements. Strong emissions of OH and H radicals dominate the optical spectra. Generally water with 500 ${\mu}S/cm$ conductivity has a breakdown voltage around 2 kV, depending on the pulse width and the repetition rate of the power supply. The characteristics of the plasma initiated in ultrapure water between pairs of different materials used for electrodes (W and Ta) were investigated by the time-resolved optical emission and the broad-band absorption spectroscopy. The deexcitation processes of the reactive species formed in the water plasma depend on the electrode material, but have been independent on the polarity of the applied voltage pulses. Recently, Coherent anti-Stokes Raman Spectroscopy method was employed to investigate the chemistry in the liquid phase and at the interface between the gas and the liquid phases of the solution plasma system. The use of the solution plasma allows rapid fabrication of the metal nanoparticles without being necessary the addition of different reducing agents, because plasma in the liquid phase provides a reaction field with a highly excited energy radicals. We successfully synthesized gold nanoparticles using a glow discharge in aqueous solution. Nanoparticles with an average size of less than 10 nm were obtained using chlorauric acid solutions as the metal source. Carbon/Pt hybrid nanostructures have been obtained by treating carbon balls, synthesized in a CVD chamber, with hexachloro- platinum acid in a solution plasma system. The solution plasma was successfully used to remove the template remained after the mesoporous silica synthesis. Surface functionalization of the carbon structures and the silica surface with different chemical groups and nanoparticles, was also performed by processing these materials in the liquid plasma.

  • PDF

Feasibility of using biogas in a micro turbine for supplying heating, cooling and electricity for a small rural building

  • Rajaei, Gh.;Atabi, F.;Ehyaei, M.A.
    • Advances in Energy Research
    • /
    • 제5권2호
    • /
    • pp.129-145
    • /
    • 2017
  • In this study, the use of a micro gas turbine system using biogas to supply heating, cooling and electricity loads of a rural building located in rural area around Tehran has been studied. Initially, the amount of energy needed by the farmhouse was calculated and then the number of needed microturbines was determined. Accordingly, the amount of substances entering biogas digester as well as tank volume were determined. The results of this study showed that village house loads including electrical, heating and cooling and hot water loads can be supplied by using a microturbine with a nominal power of 30 kW and $33.5m^3/day$ of biogas. Digester tank and reservoir tank volumes are $67m^3$ and $31.2m^3$, respectively. The cost of electricity produced by this system is 0.446 US$/kWh. For rural area in Iran, this system is not compatible with micro gas turbine and IC engine system use urban natural gas due to low price of natural gas in Iran, but it can be compatible by wind turbine, photovoltaic and hybrid system (wind turbine& photovoltaic) systems.

울진 원자력발전소 온배수를 이용한 재생식 해양온도차발전에 대한 연구 (A Study on Regenerative OTEC System using the Condenser Effluent of Uljin Nuclear Power Plant)

  • 강윤영;박성식;박윤범;김남진
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.591-597
    • /
    • 2012
  • For the past few years, the concern for clean energy has been greatly increased. Ocean thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this study, we examined the thermodynamic performance of the OTEC power system for the production of electric power. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regenerative cycle, Kalina cycle, open cycle, and hybrid cycle. The results show that the regenerative cycle showed the best system efficiency. And then we examined the thermodynamic performance of regenerative cycle OTEC power system using the condenser effluent from Uljin nuclear power plant instead of the surface water. The highest system efficiency of the condition was 4.55% and the highest net power was 181 MW.

순환여과식 사육수정화 재사용방법에 의한 Pilot 규모의 어류양식시험 (PILOT SCALE FISH PRODUCTION IN WATER RECYCLING SYSTEM)

  • 김인배
    • 한국수산과학회지
    • /
    • 제13권4호
    • /
    • pp.195-206
    • /
    • 1980
  • 면적 $26\;m^2$, 여과용 자갈 약 $15\;m^3$로 된 자갈 여과 장치에 연결된 단위면적 약 $7m^2$ 되는 사육탱크 6개와 보조탱크 2개로 구성된 장치에서 어류를 사육하면서 1980년 4월 18일부터 동 10월 14일까지의 180일간의 성장결과를 정리하여 본 결과는 다음과 같다. 1개의 사육탱크를 주실험용으로 사용했으며 이스라엘계 잉어와 이 종과 국내산 잉어 사이의 $F_1$ 잡종을 같은 수량씩 넣어 기른 결과는 총생산 461kg, 순생산 395kg였으며 그 중 이스라엘계 잉어는 약 8배로 성장했는데, $F_1$ 잡종은 약 6배로 성장했다. 남은 탱크에 수용한 잡다어류의 성장결과와 상기 생산량을 참작해 보니 이 시설을 보완개선해 가면서 이용하면 산업적 생산시도도 가능할 것으로 짐작된다. 특히 어류밀도가 높아졌을 때는 보다 효율적인 폭기방법을 이용함이 필요했다. 이 실험을 위해 만들어 사용한 부순환류이용의 고형오염물침전 제거장치는 용수절약을 위해서 효율적이며, 그 기능이 잘 발휘되었다. 가장 문제된 점은 아가미흡충의 심한 번식이었으며, Dipterex, DDVP 등의 사용으로 처음은 잘 제거되지만 곧 저항개체의 출현과 번식으로 이들 약품의 효력이 나타나지 않음을 알았다. 그리고, 이스라엘계 순종은 Dipterex 사용에 의해서 거의 대부분이 기형어로 되지만 $F_1$ 잡종 및 국내산 일반 잉어에는 기형어가 거의 나타나지 않았다.

  • PDF

분무경 시스템에서 팔레놉시스 유묘 생육에 적합한 분무간격 (Optimum Irrigation Interval for the Growth of Phalaenopsis Hybrid Seedling in the Aeroponic System)

  • 이동수;권오근;이용범;예병우;이영란
    • 생물환경조절학회지
    • /
    • 제19권4호
    • /
    • pp.234-239
    • /
    • 2010
  • 분무경시스템에서 분무간격과 분무시간은 식물의 생육어l 필요한 양분과 수분을 공급하기 위한 중요한 요소들이다. 이 실험은 분무경에서 분무간격이 팔레놉시스 유묘의 생육에 미치는 영향에 대하여 알아보고자 수행되었다. 배지 없이 뿌리가 나출된 생체중 16g 크기의 유묘를 사용하였다. 분무간격은 각각 10, 20, 30, 40, 50분 간격이었으며, 분무시간은 10분이었다. 총생체중, 총건물중, 분지된 뿌리수와 상대생장률은 20분과 30분 간격에서 10분, 40분, 50분 간격보다 높았다. 특히, 뿌리의 생체중은 30분 간격에서 기장 높았다. 엽장은 30분 간격에서 길었으나, 엽폭은 처리간 차이가 없었다. 10분 간격 처리에서 유묘 한 개체가 30일간 소비한 물량은 0.71L였으며, 분무간격이 증가함에 따라 그 양은 감소하였다. 15일간 소비된 양분은 칼륨이외에는 처리간 차이가 없었으며, 칼륨은 30분 간격에서 가장 많이 흡수되었다. 결과를 요약하면, 분무경 시스템에서 팔레놉시스 유묘 생산을 위한 적정 분무간격은 30분이었다.

공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석 (The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.

병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구 (A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

랜드스케이프 어바니즘의 관점으로 본 춘천 G5 국제설계경기 출품작 분석 (Re-reading Chuncheon G5 International Design Competition from a Viewpoint of Landscape Urbanism)

  • 김아연;고미진;오형석
    • 한국조경학회지
    • /
    • 제34권3호
    • /
    • pp.120-138
    • /
    • 2006
  • A city evolves over time. It grows, transforms, and sometimes degrades. Chuncheon is at a turning point from a city souggling with regulations regarding clean water supply and a military encampment to a masterpiece city with a sustainable vision. The city is getting ready to restructure itself to become a world-famous culture and tourism complex expanding its physical boundary across the Camp Page site and absorbing Jungdo as a major tourist attraction. The landscape in the future blueprint of Chuncheon will play a great role in restructuring urban form. The regenerated in will have a new networked open space system as well as re-evaluated landscape resources. The hybrid theoretical practice called 'landscape urbanism' burgeoning in the fields between 'landscape architecture' and 'urbanism' can guide us in considering the terms of the relationship between a city and landscape when we design a future city Landscape urbanism is considered to be an effective framework by which we can diagnose the current status of a landscape in our contemporary urban design practice in Korea. This paper tries to provide a different perspective from the viewpoint of landscape urbanism to decipher the hidden implications of the social agreement on the role of landscape in urban structure by re-reading eight design proposals presented for the ChunCheon G5 international design competition based on the main principles of landscape urbanism. The G5 design competition is a great opportunity to test out new ideas on a city, demonstrating the relative values among various urban-design professional realms. First, this paper provides an overview of the main ideas of landscape urbanism based on the literature review and case studies. Second, framework categories are suggested in order to extract the explicit and implicit ideas on the landscape. Third, eight proposals are reviewed according to the suggested categories to situate the current landscape design of Korea within the mainstream of contemporary practice of landscape urbanism. Based on the review of eight proposals, the following diagnostic conclusions are made; first, the ideas of landscape urbanism have not been actively introduced in large-scaled urban landscape projects in Korea like Chuncheon G5. Second, it remains to be a big task for landscape professions to be able to participate in design consortiums on an equal footing. Third, In order to introduce and reify the ideas of landscape urbanism in Korea, it is inevitable and critical to test the ideas in both academic fields and professional practices to find the appropriately adjusted model of landscape urbanism.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.