• Title/Summary/Keyword: Hybrid switching method

Search Result 92, Processing Time 0.031 seconds

A Novel Hybrid Five-Level Inverter for Medium-Voltage Applications (중전압 응용을 위한 새로운 하이브리드 5-레벨 인버터)

  • Dao, Ngoc Dat;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.485-486
    • /
    • 2016
  • This paper proposes a new hybrid five-level voltage-source inverter topology, based on the conventional five-level active neutral-point-clamped topology (5L-ANPC), where the lower number of switching devices is required, resulting in saving the cost. The operating principle and control method of the proposed topology is described. The comparison of THD, power losses, loss distribution, and cost of components are evaluated among the proposed topology, the 5L-ANPC and 5L-DCI (diode-clamped inverters) topology.

  • PDF

Hybrid Power Filter for the Zero Sequence Harmonics Reduction in Neutral Line (중성선 영상 고조파 전류 저감을 위한 하이브리드 전력 필터)

  • Ji, Young-Hyok;Park, Sang-Hoon;Kim, Jae-Hyung;Won, Chung-Yuen;Song, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.472-474
    • /
    • 2008
  • According to the development of power switching device technology, the power conversion system is used from the small electric power units to the large industrial instruments. These instruments are operated as harmonic sources in the grid and the harmonics cause zero sequence harmonics in the neutral line. To reduce zero sequence harmonics, the zigzag transformer is used conventionally. But the zigzag transformer can reduce only 60~70% of harmonics. In this paper, hybrid power filter for zero sequence harmonics reduction and the harmonic detection method are proposed.

  • PDF

A Gear Changing Techniques of Inverter for Variable Speed Drives on Traction Motor (견인용 전동기의 가변속 운전을 위한 인버터의 PWM패턴 절환 기법)

  • Seo, Young-Min;Jang, Dong-Ryul;Park, Hae-Dong;Hong, Soon-Chan;Park, Young-Jeen;Song, Joong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1947-1950
    • /
    • 1998
  • GTO inverter used for traction motor drives includes harmonics in the output current and torque by the limitation of switching frequency. However, the hybrid PWM method, using SPWM in low frequency range and SHE PWM in upper frequency range, can be obtained the relative less harmonic characteristic. The transient reaction, which the magnetic flux and the torque is altered and instantly the large current is flowed, may be produced at the mode change. This paper presents the techniques which can reduce the transient reactions produced in the gear changing of inverter fed traction motor drives operating in the hybrid PWM. The results are verified by the simulations.

  • PDF

Link selection based on switching between full-duplex and half-duplex modes

  • Kim, Sangchoon
    • ETRI Journal
    • /
    • v.42 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Multiple-input multiple-output systems can achieve a full sum rate (SR) via full duplex (FD). However, its performance is degraded by self-interference (SI) that occurs between the transmitter and receiver at the same node and thus is constrained by error floors. Conversely, half duplex (HD) can avoid the SI albeit at lower spectral efficiency, and the slope of its error curve is determined by the diversity order. In this study, a link selection scheme based on switching between FD and HD is examined as a simple method to improve the bit error rate (BER) performance of FD systems. In the proposed link selection algorithm, either FD or HD is selected based on the received minimum distance and signal-to-interference plus noise ratio. Simulation results indicate that the proposed hybrid FD/HD switching system offers significant BER performance improvement when compared with that of the conventional FD and FD based on only the received minimum distance under the same fixed SR. Under relatively sufficient SI cancellation, it is demonstrated to outperform the HD with a diversity advantage in low and medium signal-to-noise ratio region.

Hybrid Control of Aircraft Landing Gear using Magnetorheological Damper (MR댐퍼를 적용한 항공기 착륙장치의 하이브리드 제어기법 연구)

  • Tak, Jun Mo;Viet, Luong Quoc;Hwang, Jai-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • In this study, a hybrid control method that adjusts for the existing force control technique has been presented for consideration. The proposed hybrid control technique does away with the chattering phenomenon occurring in existing force control technique and provides high shock absorption efficiency. In order to design the controller for the landing gear with MR damper, the equation of motion of the landing gear was derived. The hybrid controller was designed after constructing a simulation model using Recur-Dyne, multi-body dynamic analysis software. The hybrid controller can reduce the maximum strut force and displacement based on the skyhook controller, and is able to get the high efficiency by making it work for the additional force control technique. In addition, an effective switching control technique and input shaping technique was applied to prevent the chattering in the drop simulation. Finally, the performance of the landing characteristics was evaluated throughout the various drop simulations.

Design and Fabrication of X-Band 50 W Pulsed SSPA Using Pulse Modulation and Power Supply Switching Method (펄스 변조 및 전원 스위칭 방법을 혼용한 X-대역 50 W Pulsed SSPA 설계 및 제작)

  • Kim, Hyo-Jong;Yoon, Myoung-Han;Chang, Pil-Sik;Kim, Wan-Sik;Lee, Jong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.440-446
    • /
    • 2011
  • In this paper, a X-band 50 W pulsed solid state power amplifier(SSPA) is designed and fabricated for radar systems. The SSPA consists of a driver amplifier, a high power amplifier, and a pulse modulator. The high power stage employes four 25 W GaAs FET to deliver 50 W at X-band. To meet the stringent target specification for the SSPA, we used a new hybrid pulse switching method, which combine the advantage of pulse modulation and bias switching method. The fabricated SSPA shows a power gain of 44.2 dB, an output power of 50 W over a 1.12 GHz bandwidth. Also, pulse droop < 1 dB meet the design goals and a rise/fall time is less than 12.45 ns. Fabricated X-band pulsed SSPA size is compact with overall size of $150{\times}105{\times}30\;mm^3$.

High Performance Control of IPMSM using SV-PWM Method Based on HAI Controller (HAI 제어기반 SV PWM 방식을 이용하나 IPMSM의 고성능 제어)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.33-40
    • /
    • 2009
  • This paper presents the high performance control of interior permanent magnet synchronous motor(IPMSM) using space vector(SV) PWM method based on hybrid artificial intelligent(HAI) controller. The HAI controller combines the advantages between adaptive fuzzy control and neural network The SV PWM method is applied to a speed control system of motor in the industry field until now and is feasible to improve harmonic rate of output current, switching frequency and response characteristics. This HAI controller is used instead of conventional PI controller in order to solve problems happening when calculating a reference voltage. The HAI controller improves speed performance by hybrid combination of reference model-based adaptive mechanism method, fuzzy control and neural network. This paper analyzes response characteristics of parameter variation, steady-state and transient-state using proposed HAI controller and this controller compares with conventional fuzzy neural network(FNN) and PI controller. Also, this paper proves validity of HAI controller.

A Study on the Utilization and Control Method of Hybrid Switching Tap Based Automatic Voltage Regulator on Smart Grid (스마트그리드의 탭 전환 자동 전압 조정기의 다중 스위칭 제어 방법 및 활용 방안에 관한 연구)

  • Park, Gwang-Yun;Kim, Jung-Ryul;Kim, Byung-Gi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.31-39
    • /
    • 2012
  • In this paper, we propose a microprocessor-based automatic voltage regulator(AVR) to reduce consumers' electric energy consumption and to help controlling peak demanding power. Hybrid Switching Automatic Voltage Regulator (HS-AVR) consist of a toroidal core, several tap control switches, display and command control parts. The coil forms an autotransformer which has a serial main winding and four parallel auxiliary windings. It controls the output voltage by changing the combination of the coils and the switches. Relays are adopted as the link switches of the coils to minimize the loss. To make connecting and disconnecting time accurate, relays of the circuit have parallel TRIACs. A software phase locked loop(PLL) has been used to synchronize the timings of the switches to the voltage waveform. The software PLL informs the input voltage zero-crossing and positive/negative peak timing. The traditional voltage transformers and AVRs have a disadvantage of having a large mandatory capacity to accommodate maximum inrush current to avoid the switch contact damage. But we propose a suitable AVR for every purpose in smart grid with reduced size and increased efficiency.

Technique for the Prevention of Inrush Current in a TCC Reactive Power Compensator

  • Yang, Ji-Hoon;Song, Sung-Geun;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.4
    • /
    • pp.149-158
    • /
    • 2018
  • With the propagation and spread of the new regeneration energy and increase in electricity demand, power systems tend to be decentralized, and accordingly, the use of a power system stabilizer tends to expand for the stabilization of the distribution system. Thus, typical power system stabilizer, Static Var Compensator (SVC) is developed on a variety of topologies. In addition, the trend of technology leads from SVC to Static Synchronous Compensator(STATCOM) technology development. Recently, to overcome STATCOM's conversion losses and economic disadvantages, studies of a hybrid method using STATCOM and SVC in parallel have actively been conducted. This study proposes a new Soft-Step Switching method to limit inrush current problematic in Thyristor Controlled Capacitor (TCC) method in SVC function. In addition, to reduce Statcom's capacity, groups of reactive power compensation reactor and condenser for SVC were designed.

A Fast Shadow Testing Algorithm during Ray Tracing. (광선추적 수행중 그림자의 빠른 검사를 위한 효과적인 알고리즘)

  • Eo, Kil-Su;Choi, Hun-Kyu;Kyung, Chong-Min
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.537-540
    • /
    • 1988
  • This paper presents a new shadow testing acceleration scheme for ray tracing called hybrid shadow testing(HST), based on conditional switching between the conventional shadow testing method and Crow's shadow volume method, with the object polygons as well as the shadow polygons registered onto the corresponding cells under the 3-D space subdivision environment. Despite the preprocessing time for the generation and registration of the shadow polygons, the total shadow testing time of the new algorithm was approximately 50 % of that of the conventional shadow testing method for several examples while the total ray tracing time was typically reduced by 30% from the conventional approach.

  • PDF