• 제목/요약/키워드: Hybrid surgery

Search Result 135, Processing Time 0.025 seconds

Hybrid Procedure for Muscular Ventricular Septal Defects -2 case reports- (근육형 심실중격결손에 대한 하이브리드 수술법 -2예 보고-)

  • Choi, Seon-Uoo;Yang, Ji-Hyuk;Jun, Tae-Gook;Park, Pyo-Won;Min, Sun-Kyung;Kang, I-Seok
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.747-750
    • /
    • 2008
  • Although surgical closure is the standard approach for a muscular ventricular septal defect, the procedure may be complicated by poor visualization and the need for incision on the ventricle. Another approach is, catheter-based intervention. However, it also has limitations. A hybrid procedure, the intraoperative combined use of an interventional device may reduce the procedure's invasiveness. We successfully managed two cases of muscular ventricular septal defect with a hybrid procedure. We report here on these 2 cases along with a review of the literature.

Hybrid Palliation for Functionally Single Ventricle with Systemic Outflow Obstruction (단심증에서의 Hybrid 고식술)

  • Cho, Won-Chul;Song, Kwang-Jae;Jung, Sung-Ho;Kim, Young-Hwee;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.927-930
    • /
    • 2006
  • Hybrid procedure was performed for a thirteen-day-old girl with a functionally single ventricle, who weighed 2.2 kg and had been prematurely born at $32^{+5}$ weeks of gestation. She underwent bilateral pulmonary artery banding using 3.5 mm Gore-Tex graft, ductal stenting using balloon expandable stent, and reverse Blalock-Taussig shunt with 3.5 mm Gore-Tex vascular graft. After discharge, she was followed up for 4 months, and underwent 2nd stage operation(extensive arch reconstruction with Damus-Kaye-Stansel anastomosis, atrial septectomy, bilateral pulmonary artery angioplasty, bidirectional cavopulmonary shunt). She has been followed up for 4 months after the 2nd operation with an excellent clinical condition.

Successful minimally invasive management using transcatheter arterial embolization in a hemodynamically stable elderly patient with mesenteric vascular injury in a hybrid emergency room system in Korea: a case report

  • So Ra Ahn;Joo Hyun Lee;Sang Hyun Seo;Chan Yong Park
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.435-440
    • /
    • 2023
  • Mesenteric injury occurs rarely in cases associated with blunt abdominal trauma. Despite its low incidence, mesenteric injury can lead to fatal outcomes such as hypovolemic shock due to hemoperitoneum or sepsis due to intestinal ischemia, or perforation-related peritonitis. For mesenteric injuries, especially those involving massive bleeding, intestinal ischemia, and perforation, the standard treatment is surgery. However, in the case of operative management, it should be borne in mind that there is a possibility of complications and mortality during and after surgery. The usefulness of transcatheter arterial embolization (TAE) is well known in solid organs but is controversial for mesenteric injury. We present a 75-year-old man with mesenteric injury due to blunt abdominal trauma. Initial abdominal computed tomography showed no hemoperitoneum, but a mesenteric contusion and pseudoaneurysm with a diameter of 17 mm were observed near the origin of the superior mesenteric artery. Since there were no findings requiring emergency surgery such as free air or intestinal ischemia, it was decided to perform nonoperative management with TAE using microcoils in hybrid emergency room system. TAE was performed successfully, and there were no complications such as bleeding, bowel ischemia, or delayed bowel perforation. He was discharged on the 23rd day after admission with percutaneous catheter drainage for drainage of mesenteric hematoma. The authors believe that treatment with TAE for highly selected elderly patients with mesenteric injuries has the positive aspect of minimally invasive management, considering the burden of general anesthesia and the various avoidable intraoperative and postoperative complications.

Visceral Debranching Thoracic Endovascular Aneurysm Repair for Chronic Dissecting Thoracoabdominal Aortic Aneurysm

  • Cho, Kwang Jo;Park, Jong Yoon
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.548-551
    • /
    • 2014
  • Type II chronic dissecting thoracoabdominal aortic aneurysms are a surgically challenging disease. The conventional thoracoabdominal aortic aneurysm repair technique using cardiopulmonary bypass is a high-risk procedure. However, a recently developed endovascular technique may be an alternative treatment for the disease, but faces the obstacle of lesional restriction. This new technique uses a hybrid strategy to overcome the limits of endovascular thoracoabdominal aortic aneurysm repair. Herein, we report on a successful outcome after performing the hybrid visceral debranching procedure.

Hybrid Approach of Ruptured Type B Aortic Dissection with an Aberrant Subclavian Artery in a Single Patient with Turner Syndrome: A Case Report

  • Son, Shin-Ah;Lim, Kyoung Hoon;Kim, Gun-Jik
    • Vascular Specialist International
    • /
    • v.34 no.4
    • /
    • pp.121-126
    • /
    • 2018
  • Turner syndrome, also described as 45, X, may present with most serious cardiovascular anomalies including risk of aortic dissection and rupture. In emergency situation, management for aortic dissection with complicated anatomy accompanying vascular anomaly is challenging. Here, we report a rare case of ruptured type B aortic dissection with aberrant subclavian artery and partial anomalous pulmonary venous connection in a Turner syndrome. Through right carotid-subclavian artery bypass and thoracic endovascular aortic repair, successful hybrid endovascular management correlated with a favorable result in this emergency situation.

A Hybrid Procedure for Coronary Artery Disease with Left Subclavian Artery Stenosis (쇄골하 동맥협착이 동반된 관상동맥질환 환자에서의 하이브리드 술식)

  • Chang, Yong-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.252-255
    • /
    • 2009
  • We performed a hybrid procedure for a 58-year-old man with coronary artery disease and a left subclavian artery stenosis. He underwent left subclavian artery stenting and off-pump coronary artery bypass surgery, including grafting the in situ left internal mammary artery to the left anterior descending coronary artery. The post-operative coronary angiogram and computed tomography showed good patency of the graft and stent. He discharged at postoperative 8 days and he has been followed up for six month with an excellent clinical condition.

Non-Operative Management with Angioembolization of Grade IV and V Renal Injuries in a Hybrid Emergency Room System

  • Ahn, So Ra;Seo, Sang Hyun;Lee, Joo Hyun;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2021
  • Renal injuries occur in more than 10% of patients who sustain blunt abdominal injuries. Non-operative management (NOM) is the established treatment strategy for lowgrade (I-III) renal injuries. However, despite some evidence that NOM can be successfully applied to high-grade (IV, V) renal injuries, it remains unclear whether NOM is appropriate in such cases. The authors report two cases of high-grade renal injuries that underwent NOM after embolization in a hybrid emergency room (ER) system with a 24/7 in-house interventional radiology (IR) team. A 29-year-old male visited Wonkwang University Hospital Regional Trauma Center complaining of right abdominal pain after being hit by a rope. Computed tomography (CT) was performed 16 minutes after arrival, and the CT scan indicated a grade V right renal injury. Arterial embolization was initiated within 31 minutes of presentation. A 56-year-old male was transferred to Wonkwang University Hospital Regional Trauma Center with a complaint of right flank pain. He had initially presented to a nearby hospital after falling from a 3-m height. Thanks to the key CT images sent from the previous hospital prior to the patient's arrival, angiography was performed within 8 minutes of the patient's arrival and arterial embolization was completed within 25 minutes. Both patients were treated successfully through NOM with angioembolization and preserved kidneys. Hematoma in the first patient and urinoma in the second patient resolved with percutaneous catheter drainage. The authors believe that the hybrid ER system with an in-house IR team could contribute to NOM and kidney preservation even in high-grade renal injuries.

Combination of Brain Cancer with Hybrid K-NN Algorithm using Statistical of Cerebrospinal Fluid (CSF) Surgery

  • Saeed, Soobia;Abdullah, Afnizanfaizal;Jhanjhi, NZ
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.2
    • /
    • pp.120-130
    • /
    • 2021
  • The spinal cord or CSF surgery is a very complex process. It requires continuous pre and post-surgery evaluation to have a better ability to diagnose the disease. To detect automatically the suspected areas of tumors and symptoms of CSF leakage during the development of the tumor inside of the brain. We propose a new method based on using computer software that generates statistical results through data gathered during surgeries and operations. We performed statistical computation and data collection through the Google Source for the UK National Cancer Database. The purpose of this study is to address the above problems related to the accuracy of missing hybrid KNN values and finding the distance of tumor in terms of brain cancer or CSF images. This research aims to create a framework that can classify the damaged area of cancer or tumors using high-dimensional image segmentation and Laplace transformation method. A high-dimensional image segmentation method is implemented by software modelling techniques with measures the width, percentage, and size of cells within the brain, as well as enhance the efficiency of the hybrid KNN algorithm and Laplace transformation make it deal the non-zero values in terms of missing values form with the using of Frobenius Matrix for deal the space into non-zero values. Our proposed algorithm takes the longest values of KNN (K = 1-100), which is successfully demonstrated in a 4-dimensional modulation method that monitors the lighting field that can be used in the field of light emission. Conclusion: This approach dramatically improves the efficiency of hybrid KNN method and the detection of tumor region using 4-D segmentation method. The simulation results verified the performance of the proposed method is improved by 92% sensitivity of 60% specificity and 70.50% accuracy respectively.

EFFECT OF DIFFERENT STERILIZATION METHODS ON THE SURFACE MORPHOLOGY OF PPDO-hybrid-PLGA NANOFIBER SCAFFOLD AND ATTACHMENTS OF PC12 CELL (다양한 소독방법이 PPDO-hybrid-PLGA nanofiber scaffold의 형태와 세포부착에 미치는 영향에 관한 연구)

  • Lee, Ju-Hyon;Min, Hyun-Gi;Jung, Ju-Young;Kang, Na-Ra
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.6
    • /
    • pp.635-639
    • /
    • 2008
  • Objectives : the effect of different sterilization methods on the surface morphology of PPDO-hybrid-PLGA nanofiber scaffold and attachments of PC12 cell were investigated. Methods : Poly (p-dioxone)-hybrid-Poly (lactide-glycolide) (PPDO-hybrid-PLGA) nanofiber scaffold, fabricated in a tube form with 1.5 mm internal diameter, 0.2 mm thickness and 5 mm length, was prepared using electrospinning method. To study the surface morphology using SEM, The study group and control group in respective were; Control:Non-sterilized scaffold, Group I:scaffold sterilized with 70% Alcohol, Group II: scaffold sterilized with Ethylene Oxide at $65^{\circ}C$, and Group III: scaffold sterilized with Ethylene Oxide at $37^{\circ}C$. To investigate viability of the PC12 cell on the scaffold, The study group and control group in respective were; Control: sterilized with 70% Alcohol, Group I: sterilized with Ethylene Oxide at $65^{\circ}C$, and Group II: sterilized with Ethylene Oxide at $37^{\circ}C$. Results : 1. The surface morphology was slightly changed in Group I, II and Group III, compared with control. 2. The attachment of PC12 cells in Group I, II was not higher than in control Discussion : The attachment of PC12 cell is not influenced by different sterilization methods.

Hybrid Operation for Arteriovenous Malformation in Left Soleus Muscle with Embolization of Feeding Artery and En Bloc Resection: A Case Report

  • Chun, Dong-Il;Kim, Seong-Min;Yun, Sangchul;Kim, Yong Jae;Goo, Dong Erk;Choi, In Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.1
    • /
    • pp.23-26
    • /
    • 2015
  • Arteriovenous malformations (AVMs) are characterized by the presence of abnormal connections between feeding arteries and draining veins. It is generally assumed that symptomatic lesions can preferably be treated. Due to high arterial blood flow, there is a risk of bleeding with surgical excision alone, which can be massive and life threatening during the operation. According to recent advances in interventional technique, a hybrid approach using embolization of the feeding artery with subsequent immediate excision of the AVM for successful management of vascular lesions could be applied to AVMs. Herein, we describe a case of successful excision of AVM in the left soleus muscle using a hybrid approach.