• Title/Summary/Keyword: Hybrid imaging

Search Result 123, Processing Time 0.026 seconds

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.

Position estimation of underground acoustic source origin using a passive SONAR system (수동형 SONAR 시스템을 사용한 지하 진원지의 추정)

  • Jarng Soon Suck;Lee Je Hyeong;Ahn Heung Gu;Choi Heun Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.103-108
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about loom underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

The Study on Composition ratio of Iodine in Hybrid X-ray Sensor (혼합형 X선 센서에서 a-Se 의 Iodine 첨가비 연구)

  • Gong, Hyung-Gi;Park, Ji-Koon;Choi, Jang-Yong;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.366-369
    • /
    • 2002
  • At present, the study of direct digital X-ray detector and indirect digital X-ray detector proceed actively. But it needs high thickness and high voltage in selenium for high ionization rate. Therefore, we carried out the study of electric characteristics of a-Se with additive ratio of Iodine in drafting study for developing Hybrid X -ray Sensor for complementing direct digital X -ray detector and indirect digital X-ray detector in this paper. On this, there are formed Amorphous selenium multi-layers by sticking phosphor layer$(Gd_{2}O_{2}S(Eu^{2+}))$ using optical adhesives of EFIRON Co. Amorphous selenium multi-layers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. We make Amorphous selenium multi-layers with $30{\mu}m$ thickness on glass.

  • PDF

Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method

  • Pamela Sung;Jeong Min Lee;Ijin Joo;Sanghyup Lee;Tae-Hyung Kim;Balaji Ganeshan
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.558-568
    • /
    • 2019
  • Objective: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. Materials and Methods: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE4), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs). Results: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration. Conclusion: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used.

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction

  • Chuluunbaatar Otgonbaatar;Jae-Kyun Ryu;Jaemin Shin;Ji Young Woo;Jung Wook Seo;Hackjoon Shim;Dae Hyun Hwang
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1044-1054
    • /
    • 2022
  • Objective: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. Materials and Methods: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods. Results: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR. Conclusion: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.

Development of hybrid shielding system for large-area Compton camera: A Monte Carlo study

  • Kim, Jae Hyeon;Lee, Junyoung;Kim, Young-su;Lee, Hyun Su;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2361-2369
    • /
    • 2020
  • Compton cameras using large scintillators have been developed for high imaging sensitivity. These scintillator-based Compton cameras, however, mainly due to relatively low energy resolution, suffer from undesired background-radiation signals, especially when radioactive materials' activity is very low or their location is far from the Compton camera. To alleviate this problem for a large-size Compton camera, in the present study, a hybrid-type shielding system was designed that combines an active shield with a veto detector and a passive shield that surrounds the active shield. Then, the performance of the hybrid shielding system was predicted, by Monte Carlo radiation transport simulation using Geant4, in terms of minimum detectable activity (MDA), signal-to-noise ratio (SNR), and image resolution. Our simulation results show that, for the most cases, the hybrid shielding system significantly improves the performance of the large-size Compton camera. For the cases investigated in the present study, the use of the shielding system decreased the MDA by about 1.4, 1.6, and 1.3 times, increased the SNR by 1.2-1.9, 1.1-1.7, and 1.3-2.1 times, and improved the image resolution (i.e., reduced the FWHM) by 7-8, 1-6, and 3-5% for 137Cs, 60Co, and 131I point source located at 1-5 m from the imaging system, respectively.

A Study on Intraoperative CT Optical Hybrid System for Brain and Spine Disease (뇌척추질환 전용 수술중 CT 광학융합 시스템에 관한 연구)

  • Jeong, Chang Won;Kim, Ji-Eon;Kim, Kyu Gyeom;Kim, Tae-Hoon;Ryu, Jong-Hyun;Jun, Hong Young;Hong, Jee Min;Kim, Dae Won;Yoon, Kwon-Ha
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.506-507
    • /
    • 2017
  • 최근 의료영상진단기기 개발 동향은 ICT 기술과 접목하는 융합진단 영상기기 개발연구로 활발하게 진행되고 있다. 특히, 수술중 CT의 개발은 임상적 미수요 충족을 위한 최첨단 기술개발로 위급한 환자를 의료영상 촬영을 위한 지정장소로 이동해야하는 문제점을 해결하여 현장 어느 곳에서 촬영할 수 있고, 환자의 다양한 의료영상을 융합하여 환자의 병변에 대한 명확한 위치와 형태 그리고 상태를 파악할 수 있도록 하며 수술을 위한 네비게이션 기능을 포함한다. 본 논문에서는 수술중 CT에 대한 설계한 사항에 대해 기술하고자 한다. 제안한 시스템의 개발은 다양한 임상현장에서 신속하게 진단과 수술을 지원할 수 있을 것으로 기대하고 있다.

Magnetic Resonance Imaging: Historical Overview, Technical Developments, and Clinical Applications

  • Jahng, Geon-Ho;Park, Soonchan;Ryu, Chang-Woo;Cho, Zang-Hee
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.35-53
    • /
    • 2020
  • The authors congratulate the cerebrations for the 30 years of the Korean Society of Medical Physics (http://www.ksmp.or.kr/). The paper is published to recognize the anniversary. Geon-Ho Jahng invited Professor Z. H. Cho to join to submit this manuscript because he has been one of the leaders in the field of magnetic resonance imaging (MRI) during the last 40 years. In this review, we describe the development and clinical histories of MRI internationally and domestically. We also discuss diffusion and perfusion MRI, molecular imaging using MRI and MR spectroscopy (MRS), and the hybrid systems, such as positron emission tomography-MRI (PET-MRI), MR-guided focused ultrasound surgery (MRgFUS), and MRI-guided linear accelerators (MRI-LINACs). In each part, we discuss the historical evolution of the developments, technical developments, and clinical applications.

Design and fabrication of plastic diffractive / refractive hybrid lenses for image communication

  • Choi, Ho-Young;Yeo, Sang-Ok;Song, Jin-Han;Moon, Hee-Jong;Park, Man-Hyo;Park, Myung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.163-164
    • /
    • 2000
  • We discuss the design and fabrication of CCD or C-MOS imaging lenses with hybrid diffractive / refractive optics. The hybrid lenses are made of optical grade plastic materials. We have been able to significantly reduce the number of elements while maintaining very high optical quality. This paper describes the conception, design, fabrication and evaluation of hybrid lenses in comparison with conventional refractive lenses. The new lens has excellent optical quality, very light weight, compact size and low manufacturing cost.

  • PDF

Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application (소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.64-72
    • /
    • 2002
  • Purpose : To introduce and demonstrate the advantages of the new hybrid two-dimensional (2D) proton spectroscopic imaging (SI) over the single voxel spectroscopy (SVS) and conventional 2D SI in the clinical application of spectroscopy for pediatric cerebral disease. Materials and Methods : Eighty-one hybrid 2D proton spectroscopic imaging was performed in 79 children (36 normal infants and children, 10 with hypoxic-ischemic injury, 20 with toxic-metabolic encephalopathy, seven with brain tumor, three with meningoencephalitis, one with neurofibromatosis, one with Sturge-Weber syndrome and one with lissencephaly) ranging in age from the third day of life to 15 years. In adult volunteers (n=5), all three techniques including hybrid 2D proton SI, SVS using PRESS sequence, and conventional 2D proton SI were performed. Both hybrid 2D proton SI and SVS using PRESS sequence were performed in clinical cases (n=). All measurements were performed with a 1.5-T scanner using standard head quadrature coil. The 16$\times$16 phase encoding steps were set on variable field of view (FOV) depending on the size of the brain. The hybrid volume of interest inside FOV was set as $75{\times}75{\times}15{\;}\textrm{mm}^3$ or smaller to get rid of unwanted fat signal. Point-resolved spectroscopy (TR/TE=1,500 msec/135 or 270msec) was employed with standard chemical shift selective saturation (CHESSI pulses for water suppression. The acquisition time and spectral quality of hybrid 2D proton SI were compared with those of SVS and conventional 2D proton SI. Results : The hybrid 2D proton SI was successfully conducted upon all patients.

  • PDF