• Title/Summary/Keyword: Hybrid collector

Search Result 66, Processing Time 0.027 seconds

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

Performance Characteristics of a Hybrid Particulate Collector (하이브리드 집진장치의 성능 특성)

  • 최호경;이시훈;김상도;박영옥
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.493-494
    • /
    • 2003
  • 본 연구에서는 전기집진 기술과 여과집진 기술의 조합에 의한 먼지입자의 포집성능 상승효과를 최대한 높일 수 있는 먼지부하 저감형 하이브리드 집진장치(Hi-Filter)를 개발하기 위한 연구의 일환으로 파일럿 규모의 실험장치에서 운전 조건을 변화시키면서 장시간 실험을 통해 집진성능 특성 변화를 고찰한다. (중략)

  • PDF

Hybrid Photovoltaic/Thermal Solar System with Pulsating Heat Pipe Type Absorber (진동형 히트파이프 흡열판이 결합된 하이브리드 태양광/열 시스템)

  • Kim, Chang-Hee;Jeon, Dong-Hwan;Kong, San-Gun;Kim, Jong-Su
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2148-2153
    • /
    • 2007
  • The electricity conversion-efficiency of solar cell for commercial application is about 6-15%. More than 85% of the incoming solar energy is either reflected or absorbed as heat energy. Consequently, the working temperature of the photovoltaic cells increases considerably after prolonged operations and the cell's efficiency drops significantly. PV/T refers to the integration of a PV module and a solar thermal collector in a single piece of equipment. By cooling the PV module with a fluid steam like air or water, the electricity yield can be improved. At the same time, the heat pick-up by the fluid can be to support space heating or service hot-water systems. In this study, a pulsating heat pipe solar heat collector was combined with single-crystal silicon photovoltaic cell in hybrid energy-generating unit that simultaneously produced low temperature heat and heat and electricity. This experiment was investigating thermal and electrical efficiency for evaluation of a PV/T system.

  • PDF

Design Evaluation of Pickup Device Collecting Deep-Sea-Manganese Nodules (심해저 망간단괴 집광기 채집장치의 설계평가)

  • Choi, Jong-Soo;Lee, Tae-Hee;Hong, Sub;Sim, Jae-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.68-74
    • /
    • 1998
  • Performance and efficiency of deep seabed collector is a primary factor for feasibility of commercial deep ocean mining. The efficiency of manganese nodules collector depends on vehicle mobility relative to undulating seafloor and is attributed pickup head to keep altitude and elevation of it against seafloor. For this reason, motion control of pickup head relative to the changing deep-sea topography and other disturbances is of particular importance in design of pickup device. The concept of design axiom is applied to a pickup device of hybrid type in order to evaluate the concept design. Kinematic analysis conducted in absolute Cartesian coordinates gives position, velocity, and acceleration of the hydraulic cylinders which enable the pickup head to keep the preset optimal distance from seafloor. Inverse dynamic analysis provides the driving forces of hydraulic cylinders and the reaction forces at each joint. Design sensitivity analysis is performed in order to investigate the effects of possible design variables on the change of the maximum strokes of hydraulic cylinders. The direct differentiation method is used to obtain the design sensitivity coefficients.

  • PDF

A Study on Light Collector and Luminaire Design using Microstructured Film (미세 필름을 이용한 집광 및 조명장치 연구)

  • Jeong, Hak-Geun;Jung, Bong-Man;Han, Su-Bin;Lee, Euy-Jun
    • KIEAE Journal
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 2002
  • Solar daylighting system provides free and comfort lighting, but its cost has been key issue due to difficult design and control of the heavy light collecting system. One of the solutions for the heavy design issues would be using a light framed film such fresnel and prism lens. Prism light guide luminaires have for some time been used to distribute light when it is desirable to have remote light sources. These systems are helpful when it is desirable to have fewer light sources, and/or to position light sources in places where lamp maintenance is easier, or electrical hazard is reduced. This proposed prototype system consists of light collector, light transformer and light pipe.

Simulation of Solar/Absorption Cooling Hybrid System and Examination of Its Operating Condition (태양열을 이용한 흡수식 냉방시스템의 시뮬레이션과 운전조건의 검토)

  • Her, Jae-Young;Lee, Sang-Yong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 1985
  • Solar/absorption cooling system was analyzed and its operating condition was examined. For the system, the optimum size of absorption refrigerator and collector area should be determined. As the temperature of water supplied to the generator increases, the collector efficiency decreases whereas the coefficient of performance of absorption refrigerator increases up to a certain point, and vice versa for decreasing of the temperature of water supplied to the generator . Thus if the reeling load is given, the appropriate operating condition can be determined between the two opposing trends by simulation program. As an example of the simulation, the case of Jejudo province was studied. Under the conditions (such as weather data and prices of components, etc.) given en the sample calculation, the result shows that the optimum temperature of water supplied to the generator turned out to be $80.3^{\circ}C$, and still shows a large economical disadvantage in present stage compared to the case of conventional vapor compression cooling/heating combined heat pump system.

  • PDF

Solar power and desalination plant for copper industry: improvised techniques

  • Sankar, D.;Deepa, N.;Rajagopal, S.;Karthik, K.M.
    • Advances in Energy Research
    • /
    • v.3 no.1
    • /
    • pp.59-70
    • /
    • 2015
  • In India, continuous production of electricity and sweet/potable water from Solar power and desalination plant plays a major role in the industries. Particularly in Copper industry, Solar power adopts Solar field collector combined with thermal storage system and steam Boiler, Turbine & Generator (BTG) for electricity production and desalination plant adopts Reverse osmosis (RO) for sweet/potable water production which cannot be used for long hours of power generation and consistency of energy supply for industrial processes and power generation cannot be ensured. This paper presents an overview of enhanced technology for Solar power and Desalination plant for Copper industry making it continuous production of electricity and sweet/potable water. The conventional technology can be replaced with this proposed technique in the existing and upcoming industries.

A Study of Performance Characteristics on Hybrid Heat Pump System with Solar Energy as Heat Source (태양열이용 하이브리드 열펌프시스템의 성능특성에 관한 연구)

  • Park, Youn-Cheol;Kim, Ji-Young;Ko, Gwan-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2007
  • Interests on renewable energy are increased due to oil price and environmental problems aroused from the fossil energy usage. In this study, performances of a solar assisted hybrid heat pump system are analyzed by experimental method. The developed system could runs at two types of operating mode. When the storage temperature is higher than the set temperature, the stored hot water in storage tank is supplied to the load directly. On the other hand, when the storage temperature lower than the set temperature, the water inside of the storage tank is used as heat source of the heat pump. In this study, the system control temperature for the alternation of the operating mode is set to $40^{\circ}C$ of the storage tank outlet. As results, it is founded that the COP of the developed heat pump system shows between 3.0 and 3.5. It is resonable performance for the heating system with a renewable energy as secondary heat source. The solar collect used in this study could supplies heat to the storage tank at over 400 W/m2 solar intensity. If the irradiation is lower than the 400 W/m2, the circulation pump stored and it could not supply heat to the storage tank. It is found that the difference temperature between the outlet of the storage tank and collector is $3^{\circ}C$. Even though, the extended study should be conducted to get a optimum performance of the developed system with various operating condition and control strategies.

A Numerical Study on an Optimum Design of a Hybrid Collector Coupled with the Principle of Cyclone, Baffle and Bag-Filter (싸이클론과 배플 및 백필터 원리를 결합한 하이브리드형 집진기의 최적화 설계를 위한 수치해석)

  • Hong, Sung-Gil;Jung, Yu-Jin;Lim, Ki-Hyuk;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.983-989
    • /
    • 2013
  • The current research reviewed the design conditions that would maximize the efficiency of the hybrid collector that combines in one unit "cyclone-inertial impaction-bag filter". The computational analysis for the shape of cyclone entry predicts that a design that installs the guide vane at the entry of the tangential type cyclone brings a high-rpm and powerful vortex, very effective in promoting the deflection of coarse particles from the streamline at the cyclone. As the lower part of the cyclone is venturi-shaped, however, a strong flow downward of 4 to 5 m/sec persists through the lower part of the hopper, revealing the likely reentrainment of collected dust. And the removal of the venturi at the lower part of the cyclone would solve the problem of the reentrainment of collected dust. The acceleration of the flow velocity through the adjustment of the gap of the collision baffle would increase the effect of collision, but as the interference with the dust separation is expected, the original design should be kept for the baffle.