• Title/Summary/Keyword: Hv

Search Result 1,039, Processing Time 0.037 seconds

A Study of the Fractal Image Compression with a Quadtree Partioning Method and a HV Partitioning Method (Quadtree 분할방식과 HV 분할방식을 이용한 프랙탈 이미지 압축에 관한 연구)

  • Byun, Chae-Ung;Lee, Key-Seo;Chung, Chin-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.980-982
    • /
    • 1995
  • Image coding based on a fractal theory of iterated transformations presents highly compressed image. In this paper, we compress image using the partitioning method which devides image adaptively in horizon and vertical axis. This method can encode image more compactly than the quadtree partitioning method. The maximum range size can be selected as $32{\times}32$ blocks and the minimum size can be $4{\times}4$ blocks. And the domain size is twice as many as the range size.

  • PDF

PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor (prototype 패치 안테나를 이용한 고압 회전기의 부분방전 측정 연구)

  • Lwin, K.S.;Shin, D.H.;Lim, K.J.;Kong, T.S.;Kim, H.D.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.169-171
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of elaine testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.

  • PDF

Characteristic Analysis of PD Occurrence Aspects for Defect of Stator Coil in HV Induction motor (고압 유도전동기 고정자권선의 결함에 따른 부분방전발생양상의 특징분석)

  • Lee, Kang-Won;Kim, Myung-Yong;Baik, Kwang-Sun;Jang, Dong-Uk;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2226-2228
    • /
    • 2005
  • High voltage induction motor is the important equipment for ensuring the driving performance of the electric train. PD(partial discharge) is a good indicator for showing the insulation performance of stator coil in HV induction motor. This paper has investigated the characteristics of PD occurrence aspects for both the sound and defective stator coil which consist of maximum PD amplitude(V), total occurrence number, average PD amplitude(V) and PD amplitude(v) - PD occurrence number(n). They were compared with each other depending on applied voltages and reconstructed to $60{\times}60$ matrices of PD amplitude(v)-occurrence phase (${\phi}$)-occurrence number(n) which is the good way to estimate the PD sources in stator coil.

  • PDF

Microstructural Characterization and Plasma Etching Resistance of Thermally Sprayed $Al_2O_3$ and $Y_2O_3$ Coatings

  • Baik, Kyeong-Ho;Lee, Young-Ra
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.234-235
    • /
    • 2006
  • In this study, the plasma sprayed $Al_2O_3$ and $Y_2O_3$ coatings have been investigated for applications of microelectronic components. The plasma sprayed coatings had a well-defined splatted lamellae microstructure, intersplat pores and a higher amount of microcracks within the splats. The plasma sprayed $Y_2O_3$ coating had a relatively lower hardness of 300-400Hv, compared to 650-800Hv for $Al_2O_3$ coating, and would be readily damaged by mechanical attacks such as erosion, wear and friction. For a reactive ion etching against F-containing plasmas, however, the $Y_2O_3$ coating had a much higher resistance than the $Al_2O_3$ coating because of the reduced erosion rate of by-products.

  • PDF

Load Carrying Effect on the Biomechanical Parameters of Slips and Falls (미끄러져 넘어짐의 생체학적 연구에 있어서 부하이동이 끼치는 영향)

  • Myung, Ro-Hae
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.27 no.2
    • /
    • pp.197-202
    • /
    • 2001
  • The biomechanical analysis of the load carrying effect on different floor surfaces has been conducted. Four different floor surfaces were prepared for ten subjects with each walking at a fixed velocity(1.33 m/sec) while carrying five different loads. The results showed that because of the significant interaction effect between floor slipperiness and the load carrying task, the load carrying effect should be analyzed according to different levels of the floor slipperiness, especially contaminant floors. On oily surfaces, slip distance(SD) and heel velocity (HV) increased whereas stride length(SL) decreased as load increased. In other words, significantly longer SD, faster HV, and no normal gait were found as load increased. As a result, a different protocol should be applied to measure floor slipperiness on oily floors as compared to dry surfaces for tribological approach.

  • PDF

Electrical Insulation Breakdown Strength in Epoxy/Spherical Alumina Composites for HV Insulation

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.105-109
    • /
    • 2013
  • In order to develop high voltage (HV) insulation materials, epoxy/spherical alumina composites with two different particle sizes (in ${\mu}m$) were prepared and a dynamic mechanical analysis (DMA) and electrical insulation breakdown strength test were carried out in sphere-sphere electrodes and the data were estimated using Weibull statistical analysis. Alumina content varied from 50 to 70 wt%. The electrical insulation breakdown strength for epoxy/alumina (50 wt%) was 44.0 kV/1 mm and this value decreased with increasing alumina content. The effects of insulation thickness and alumina particle size on the insulation breakdown strength were also studied. The insulation thickness varied from 1 mm to 3 mm, and the particle sizes were 7.3 or $40.3{\mu}m$.

A Research Trend on On-Line/Off-Line PD Insulation Diagnostic System (온라인 및 오프라인 PD 모니터링에 관한 연구 동향)

  • Choo, Jong-Hoon;Hong, Chang-Il;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2008-2009
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is introduced.

  • PDF

Enhanced drought tolerance by expression of hvDhn5 gene in poplar

  • Han, Mu-Seok;Noh, Eun-Woon
    • Journal of Plant Biotechnology
    • /
    • v.38 no.3
    • /
    • pp.203-208
    • /
    • 2011
  • We transferred Dhn5 (dehydrin5) gene from barley to poplar to determine the effect of its expression on the transgenic poplars. The results from northern blot analysis showed that the expression level of gene varied among the transgenic lines. During their culture on tissue culture media, the transgenic poplars formed vigorous growing callus in the presence of 5% PEG. When the transgenic poplars were growing in pots and witheld watering, they stayed much healthier than nontransgenic poplars. The transgenic poplars showed higher rates of photosynthetic rates, stomatal conductance and evaporation rates under the drought stress, although there was no significant difference in soil water content within the treatments. The relative electrical conductivity of the transgenic poplars after 20% PEG treatment was lower than that of nontransgenic poplars. The results provide evidence that the expression of hvDhn5 gene conferred drought tolerance in the transgenic poplars.

Surface Hardening of Tool Steels Using Laser Beam (레이저 빔을 이용한 공구강의 표면 경화)

  • Nam, K.S.;Lee, K.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.10 no.1
    • /
    • pp.71-78
    • /
    • 1997
  • This work was to investigate suitable tool steels for hardening using laser beam, and was studied on carbon tool steels and alloyed tool steels such as STC3 steel, STS3 steel, STD11 steel and SKH51 steel. The surface hardness of HV700-1000 and the hardening depth of 2-2.5mm were obtained on STC3 steel and STS3 steel, and HV800-1000 was obtained on SKH51 steel, but STD11 steel was not enough. Except STD11 steel, all steels used in this study can be hardened by laser quenching or laser rapid melting.

  • PDF

Effect of temperature on the surface properties of low temperature plasma nitrocarburized AISI304L stainless steel (AISI304L stainless steel의 저온 플라즈마 질탄화 시 처리온도가 표면 조직에 미치는 영향)

  • Lee, In-Seop;Jeong, Gwang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.04a
    • /
    • pp.118-119
    • /
    • 2007
  • 오스테나이트계 스테인리스 AISI304L강을 저온 플라즈마 분위기에서 표면에 C와 N을 주입하면 내식성의 저하 없이 표면경도를 증가 시킬 수 있다. 이 공정에서 온도에 따른 영향을 조사하기위해 $380^{\circ}C{\sim}430^{\circ}C$의 온도 범위에서 20시간 동안 실시하였다. 경화층의 두께는 $7{\sim}16\;{\mu}m$정도였으며, N의 농도가 높은 영역과 C의 농도가 높은 영역으로 나뉘어 형성되었고, N이 풍부한 영역이 표면층에 형성되고 그 아래에 C의 농도 높은 영역이 형성되었다. 표면층은 질소에 의해 확장된 오스테나이트(${\gamma}_N$)상을 가지며 고온에서 처리한 경우 석출물이 형성되었다. 표면경도는 약 $900\;HV_{0.01}{\sim}1200\;HV_{0.01}$로 측정되었다.

  • PDF