• Title/Summary/Keyword: Humidity variation

Search Result 403, Processing Time 0.028 seconds

An Experimental Study of the Effect of Regeneration Area Ratio on the Performance of Small-Sized Dehumidification Rotor for Residential Usage (재생 면적비가 가정용 소형 제습로터의 성능에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.277-282
    • /
    • 2015
  • During hot and humid weather, air-conditioners consume a large amount of electricity due to the large amount of latent heat. Simultaneous usage of a dehumidifier may reduce latent heat and reduce electricity consumption. In this study, dehumidification performance was measured for a small-sized dehumidification rotor made of inorganic fiber impregnated with metallic silicate within a constant temperature and humidity chamber. Regeneration to dehumidification depends on ratio, rotor speed, room temperature, regeneration temperature, room relative humidity and frontal velocity to the rotor. Results demonstrate an optimum area ratio (1/2), rotor speed (1.0 rpm), and regeneration temperature ($100^{\circ}C$) to achieve a dehumidification rate of 0.0581 kg/s. As the area ratio increases, the optimum rotation speed and the optimum regeneration temperature also increase. Above the optimum rotor speed, incomplete regeneration reduces dehumidification. Above the optimum regeneration temperature, increased temperature variation between regeneration and dehumidification reduces dehumidification. Dehumidification rate also increases with an increase of relative humidity, dehumidification temperature and flow velocity into the rotor.

An Experimental Study of the Variation of the Moisture Content of Plywood and the Change of Thermal Conductivity of Plywood According to its Moisture Content (습도 조건에 따른 합판의 함수율 변화와 함수율에 따른 합판의 열전도율 변화에 대한 실험적 연구)

  • Lee, Jin-Sung;Kim, Kyung-Su;Kang, Jung-Kyoo;Yoo, Chang-hyuck
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.367-371
    • /
    • 2018
  • Plywood is one of the important materials in LNG cargo containment systems, and, due to the characteristics of the wood, its properties vary greatly depending on the humidity conditions in the storage facility. Due to the distribution environment of plywood, there is a high probability of long-term exposure to the domestic seasonal environment. Considering an environment in which the humidity changes greatly according to the seasons in Korea and the characteristics of the wood, it is necessary to acquire data on changes in the characteristics of the plywood for accurate quality control. In this study, the moisture content of plywood was determined experimentally to reflect the seasonal environmental conditions of shipyards in Korea. A noticeable change in the thermal conductivity was confirmed experimentally.

Study on Environmental Monitoring in Stack Room for Paper Storage Using the Preservation Index (보존 환경 평가 지수를 이용한 종이 보존 서고 환경 모니터링 연구)

  • Shin, Hyun-Chang;Yoon, Man-Young
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.1
    • /
    • pp.61-74
    • /
    • 2011
  • Critical environmental elements for long term preservation of a paper are temperature, humidity, dust, light, contaminants in air, and mold. Especially, temperature and humidity need special care, because they can not only directly degrade paper but also affect the degradation of the other elements. Therefore methods to monitor variation of temperature and relative humidity were studied. One of the methods was to use preservation index for evaluating preservation environment. Since the evaluation for preservation environment of a stack room investigated firstly by D. K. Sebera, PI(preservation index) and TWPI(Time-Weighted Preservation Index) by IPI is made to evaluate relatively preservation environment in a stack room. T. Padfield developed method which could calculate easy PI and TWPI. In this study, the preservation environment of stack rooms for paper storage in NAK(National Archives Korea) was evaluated by PI and TWPI. PI and TWPI of stack rooms for paper storage in NAK maintained good condition but PI depended on season. Then the preservation environment of stack rooms for paper storage in NAK was required to maintain continuously PI and TWPI regardless of season change.

Variation of Hydro-Meteorological Variables in Korea

  • Nkomozepi, Temba;Chung, Sang-Ok;Kim, Hyun-Ki
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.3
    • /
    • pp.135-143
    • /
    • 2014
  • The variability and temporal trends of the annual and seasonal minimum and maximum temperature, rainfall, relative humidity, wind speed, sunshine hours, and runoff were analyzed for 5 major rivers in Korea from 1960 to 2010. A simple regression and non-parametric methods (Mann-Kendall test and Sen's estimator) were used in this study. The analysis results show that the minimum temperature ($T_{min}$) had a higher increasing trend than the maximum temperature ($T_{max}$), and the average temperature increased by about $0.03^{\circ}C\;yr.^{-1}$. The relative humidity and wind speed decreased by $0.02%\;yr^{-1}$ and $0.01m\;s^{-1}yr^{-1}$, respectively. With the exception of the Han River basin, the regression analysis and Mann-Kendall and Sen results failed to detect trends for the runoff and rainfall over the study period. Rapid land use changes were linked to the increase in the runoff in the Han River basin. The sensitivity of the evapotranspiration and ultimately the runoff to the meteorological variables was in the order of relative humidity > sunshine duration > wind speed > $T_{max}$ > $T_{min}$. Future studies should investigate the interaction of the variables analyzed herein, and their relative contributions to the runoff trends.

An Experimental Study on Non-hygroscopic Propertiy of PAG and POE Oils for a $CO_2$ Refrigeration System ($CO_2$ 냉동시스템용 PAG오일과 POE오일의 항흡습성에 관한 실험적 연구)

  • Lee, Sung-Kwang;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.388-393
    • /
    • 2008
  • This study has been conducted to select the suitable refrigeration oil for a $CO_2$ refrigeration system. Non-hygroscopic property of refrigeration oils is one of the most important properties for refrigeration oils. PAG and POE oils are considered as test oils in this study. Transient variation of water content of PAG and POE oils was measured for 3 different vessels in the environmental conditions, such as in the range of temperature $25^{\circ}C$ to $40^{\circ}C$ and relative humidity 40% to 85%. The results obtained that water content of both POE and PAG is increased with an increase in the contact area with ambient for 3 different vessels. It is also found that water content of both POE and PAG is increased as the ambient temperature and relative humidity is increased. Non-hygroscopic property of POE oil is found to be much superior than that of PAG oil.

Short-term Variation in Class A Pan Evaporation (대형증발계 증발량의 일 변화)

  • 이부용
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.4
    • /
    • pp.197-202
    • /
    • 2002
  • A new method is used to estimate the amount of water evaporation from Class A Pan with higher precision and accuracy. The principle of method is to detect the weight change of a buoyant sinker resulting from a change in water level of Class A Pan. A strain-gauge load cell is used to measure the weight change. Field observation of evaporation was done at Pohang Meteorological Station from June 24 to August 4, 2002. By using this new method, it is possible to measure hourly evaporation accurately even under a strong solar radiation and wind disturbance, enabling a direct comparison of evaporation with other meteorological elements. At night, under low humidity and high wind speed conditions, more evaporation was recorded than during daytime. Maximum evaporation rates observed during this period exceed 1.0 mm/hour under the sunny and windy conditions with low humidity. To understand relationships between meteorological elements and latent heat flux at ground level, we suggest intensive held experiments using high accuracy evaporation recording instruments with hourly time interval.

Hydrogen Peroxide Concentrations in Air in Seoul (서울시 대기 중 $H_2O_2$의 농도)

  • 강충민;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.61-68
    • /
    • 2000
  • Gas-phase hydrogen peroxide(H2O2) concentrations were measured to investigate it's distribution in the ambient air in downtown Seoul(Kwanghwamum and Mullae-dong). These measurements were made during four season, from April 30, 1998 to January 29, 1999, using Cold Trap and HPLC. Measurements were also made of other photochemical oxidants and trace gases(O3, NO2, CO and SO2) and meteorological parameters(relative humidity, temperature, solar radiation and wind speed). The mean of all observations was 0.10 ppbv and the range measured was below the level of detection(>0.01 ppbv) to 0.47ppbv. The higher seasonal mean concentrations showed during the summer(0.21 ppbv) and concentrations of H2O2 showed a diurnal variation with maximum concentrations in the afternoon(12:30∼14:00). The results from the corrrelation analysis showed that the concentration of gaseous H2O2 is strongly dependent on the other air pollutants(NO2, CO and O3) and meteorological parameters(relative humidity, temperature and solar radiation.)

  • PDF

Prediction of Temperature and Moisture Distributions in Hardening Concrete By Using a Hydration Model

  • Park, Ki-Bong
    • Architectural research
    • /
    • v.14 no.4
    • /
    • pp.153-161
    • /
    • 2012
  • This paper presents an integrated procedure to predict the temperature and moisture distributions in hardening concrete considering the effects of temperature and aging. The degree of hydration is employed as a fundamental parameter to evaluate hydro-thermal-mechanical properties of hardening concrete. The temperature history and temperature distribution in hardening concrete is evaluated by combining cement hydration model with three-dimensional finite element thermal analysis. On the other hand, the influences of both self-desiccation and moisture diffusion on variation of relative humidity are considered. The self-desiccation is evaluated by using a semi-empirical expression with desorption isotherm and degree of hydration. The moisture diffusivity is expressed as a function of degree of hydration and current relative humidity. The proposed procedure is verified with experimental results and can be used to evaluate the early-age crack of hardening concrete.

Analysis of Environment Control Capability Wintering Beehouse in Young Area (용인지역 저온양봉사의 환경조절성능 분석(농업시설))

  • 이석건;김란숙;이현우;이종원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.302-307
    • /
    • 2000
  • The wintering honey bee chambers were constructed and inside environment factors were analyzed to provide high technology for efficient wintering of honeybee colonies. As a result of this study, inside air temperature of yongin chamber under the wide range of outside temperature condition was found to be appropriated for wintering of bee, and inside temperature of beehive was about 2$^{\circ}C$ higher than the air temperature in the chamber. The fan operation schedule did not control the high temperature down properly in the chamber, It was necessary to find a new fan operation schedule to be able to provide the optimum temperature for wintering honey bee colonies. inside humidity variation of Yongin chamber was very much depended on outside humidity.

  • PDF

Study on the Characteristics of Low Level Atmosphere Observed in Pusan Coastal Ares (부산연안에서 관측된 저층대기의 특성에 관한 연구)

  • 전병일;김유근
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • The low level atmospheric obsewation carried out to Investigate magnitude, formation and dissipation of nocturnal surface Inversion layer, also to survey relation to each meterological parameter In Inversion layer at Pusan power plant for Oct. 13, 1996. As coastal area, the surface Inversion layer height was relatively high(186m), and after sunset unstable layer formated firom surface to around 40m, and the Inversion layer was left still in the upper layer. The surface Inversion layer dissipated at 0920LST perfectly. The layer that strong Inversion layer was formated, showed steep variation of potential temperature and wand speed and relative humidity.

  • PDF