• Title/Summary/Keyword: Humidity measurement

Search Result 468, Processing Time 0.035 seconds

Effect of Ambient Temperature and Humidity on Corrosion Rate of Steel Bars in Concrete (환경 온·습도가 콘크리트 내 철근의 부식 속도에 미치는 영향 분석)

  • Du, Rujun;Jang, Indong;Cho, Junghyun;Yi, Chongku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.307-308
    • /
    • 2021
  • Corrosion of reinforced steel inside concrete is an important cause of performance degradation of reinforced concrete structures and has a profound influence on the durability of structures. In this study, three groups of different reinforced concrete structures exposed to the natural environment were subjected to chloride ion accelerated corrosion tests for up to 180 days. The corrosion velocity and ambient temperature of the samples were measured and recorded every day. Based on Faraday's law, the corrosion speed of steel bars could be measured, and the ambient temperature and humidity around the structure in corresponding time were compared. Through the measurement of up to 180 days, the influence of external ambient temperature and humidity on the corrosion speed of steel bars inside the concrete structure was found out. The results show that there is a good direct proportional relationship between temperature and corrosion speed. When the ambient temperature increases by 15℃, the corrosion rate increases by about one time.

  • PDF

Humidity Sensor Using Polyimide Film Coated Fiber Bragg Grating (폴리이미드가 코팅된 광섬유 브래그 격자를 이용한 습도센서)

  • Jae Chang Yang;Gun Pyo Kim;Kwang Taek Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.594-597
    • /
    • 2023
  • We have proposed and demonstrated a fiber optic RH (relative humidity) sensor based on fiber Bragg grating covered with a polyimide film. As the polyimide film absolves the moisture in the air, its volume expands. As a result, the grating period of the FBG (fiber Bragg grating) covered with a polyimide film becomes wide and the Bragg wavelength is shifted. The sensor is implemented by fixing a 30 ㎛ thickness polyimide film on the surface of an optical fiber grating using an adhesive, and the characteristics of the device according to humidity are analyzed. The fabricated FBG RH sensor showed a high sensitivity of 0.0186 nm/RH% and a wide measurement range from 30% to 90%. The influence of environmental temperature on the characteristics of the RH sensor was also measured and analyzed. The feasibility of commercialization is presented.

A Study for Implementation of Density Measurement Equipment for Asphalt Pavement based on the electromagnetic capacitance

  • Park, Young-Ho;Kim, Gun-Kyun;Nor, Jeong-Keun;Ha, Jae-Kwon
    • International Journal of Contents
    • /
    • v.6 no.4
    • /
    • pp.39-42
    • /
    • 2010
  • In this paper we developed density measurement equipment for Asphalt Pavement based on the electromagnetic capacitance. This kind of Non-Nuclear Density Gauges technology and products is used or studied in USA, Finland, Sweden as standardization of authorized method for pavement density measurement. Effective permitivity of pavement asphalt is characterized in electromagnetic capacitance by the asphalt material, mixed ratio, and harden grade of pavement asphalt. We can get a density value of asphalt by replacing value of electromagnetic capacitance with standard density value and characteristic transformation curve. We are conformed that measurement data according to temperature, humidity, and real field asphalt of our density measurement equipment can be a precise value.

On-Machine Measurement of an Optical Surface by Hartmann Test (하트만 방법에 의한 광학면의 기상측정)

  • 김용관;오창진;이응석;김옥현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.474-480
    • /
    • 2002
  • Aspheric optical lenses and mirrors are widely used in recent. It is more difficult to manufacture and measure the aspherical optics compared to conventional spherical ones. The interferometric optical test is common for the measurement of spherical optical surface. But the application of the interferometry to the measurement of aspheric surface is difficult because it needs a precise null corrector and very careful environmental conditions such as keeping constant temperature, humidity, atmospheric pressure and vibrations. To enhance productivity of optics manufacturing on-machine measurement and correction has been developed in this study. For practical applications, robustness of the measurement method to environments is more important. For the purpose an optical OMM(On-Machine Measurement) system has been developed using Shack-Hartmann test which has robustness to the environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by least square fitting. The measured result of the developed only system gives the maximum deviation only in 200 nm from the result measured by a commercial Fizeau interferometer Wyko 6000.

  • PDF

Measurement of Humidity Distribution in a Proton Exchange Membrane Fuel Cell Using Channel Embedded Humidity Sensors (채널 내장형 습도 센서를 이용한 고분자 전해질 연료전지의 습도분포 측정)

  • Lee, Yongtaek;Yang, Gyung Yull
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.5
    • /
    • pp.397-403
    • /
    • 2015
  • In this study, water distribution inside a proton exchange membrane fuel cell (PEMFC) was measured experimentally. Water distribution is non-uniform because of vigorous chemical reaction and mass transport and has been difficult to measure experimentally. Therefore, much research relied on indirect measuring methods or numerical simulations. In this study, several mini temperature-humidity sensors were installed at the channel for measuring temperature and humidity of the flowing gas throughout the channel. Only one of two electrode channels was humidified externally, and the humidity distribution on the other side was measured, enabling the observation of water transport characteristics under various conditions. Diffusion through the membrane became more vigorous as the temperature of the humidifier rose, but at high current density, electro-osmotic drag became more effective than diffusion.

Measures to Improve the Efficiency of the Portable Air Quality Measurement System

  • CHOI, Jong-Sun;CHO, Dong-Myung;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.3
    • /
    • pp.27-41
    • /
    • 2022
  • Purpose: In this study, pollutants generated in industrial areas were measured using a Portable Air Quality Measurement System(PAQMS). This study intends to examine in detail improvement measures and operational capabilities to operate a more efficient PAQMS. Research design, data and methodology: This study compares and analyzes the measurement values of the PAQMS and the measurement values of the national air quality measurement network. It is intended to develop a PAQMS corresponding to the data of the national measurement network by minimizing the errors that occur during comparative measurement and analysis and supplementing and improving the problems that occur during the current equipment calibration. Results: A PAQMS is an essential equipment for faster and more accurate measurement and analysis of pollutants in case of untimely measurement and civil complaints due to Micro Climate(local weather and environmental influences). Currently, there are many atmospheric measurement equipment in Korea, but only equipment for each item is produced and sold. Currently, these devices on the market must satisfy various conditions such as stable power, temperature, and humidity to calculate accurate measurement values. Conclusions: Therefore, there is no equipment that satisfies the conditions for performing detailed measurement in the field where accurate measurement is required. In this study, these field work conditions and contents for stable measurement were mentioned in the text.

Measurement of Thickness of Still Air Layer above Fabrics (직물의 표면 정지 공기층의 두께 측정)

  • 나영주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1117-1123
    • /
    • 1997
  • This paper describes the measurement of thickness of still air layer above fabrics and its relationship to structural properties of fabrics. Rayon fabrics - of both filament and spun - and wool nylon blended fabrics varied in terms of surface hairiness were used. Temperature and relative humidity above fabrics were measured at the various distances from the fabric surface. Increase in the thickness of fabric, fabric weight, yarn count, and crimp resulted increase in thickness of still air layer above fabric. Surface hairiness of fabrics as well as the structural properties were found to be related with the thickness of still air layer above fabrics.

  • PDF

얼굴근전도와 얼굴표정으로 인한 감성의 정성적 평가에 대한 연구

  • 황민철;김지은;김철중
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.264-269
    • /
    • 1996
  • Facial expression is innate communication skill of human. Human can recognize theri psychological state by facial parameters which contain surface movement, color, humidity and etc. This study is to quantify or qualify human emotion by measurement of facial electromyography (EMG) and facial movement. The measurement is taken at the facial area of frontalis and zygomaticus The results is indicative to discriminate the positive and negative respond of emotion and to extract the parameter sensitive to positive and negative facial-expression. The facial movement according to EMG shows the possibility of non-invasive technique of human emotion.

  • PDF

Derivation of Consideration Factors for Fine Dust Measurement through GIS Mapping (단지조성공사의 미세먼지 측정 및 GIS Mapping을 통한 미세먼지 측정 고려요소 도출)

  • Kim, Young Hyun;Han, Jae Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.163-164
    • /
    • 2020
  • When measuring fine dust at a large-scale site such as complex construction, the change in the value of fine dust measurement is large due to the influence of the time, location, wind speed, wind direction, and humidity. This study aims to find out the results of measuring fine dust in an actual construction site and inferring the changes.

  • PDF

The effect of diffusers on the measurement of sound absorption in a reverberation room (잔향실법 흡음률 측정에 미치는 확산체의 영향)

  • Han, Hee-Kab;Kim, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF