• 제목/요약/키워드: Humidity freezing

검색결과 46건 처리시간 0.023초

동결건조 시스템에서 동결속도가 향미물질 보존에 미치는 영향 (Influence of Freezing Rate on the Aroma Retention in a Freeze Drying System)

  • 변명희;최미정;이성;민상기
    • 한국축산식품학회지
    • /
    • 제18권2호
    • /
    • pp.176-184
    • /
    • 1998
  • The objective of this study was to investigate the effects of freezing rate on aroma retention and to examine the mechanism of aroma retention during freeze drying process. Our experiments were carried out with self-manufactured freeze-dryer. Gelatin gels (2% w / w, 80${\times}$20mm) containing diacetyl(2mg/ml) were frozen unidirectionally (Neumann's model) from the bottom at -45, -30, -20, and -15$^{\circ}C$ and followed with freeze-drying. Under the upper conditions we measured freezing rate and the change of temperature and pressure during freeze drying. Freeze-dried gelatins were cut horizontally into 5 mm thickness from the bottom measured and diacetly contents. Besides, we observed the effect of the relative humidity of the diacetyl contents freeze-dried gelatin during storage. The retained diacetyl content was increased at high freezing temperature and in order of 0∼5, 5∼10, 10∼15, 15∼20 mm section from the bottom of the sample. It was observed that the retained diacetyl content was high in 15∼20 mm section. The retained diacetyl content and freeze-dried gelatin stored in the condition of high relative humidity was decreased significantly but in the low relative humidity case, was it decreased in small amount. The results of our experiment resents that the low temperature freezing and low humidity storing condition is effective for preserving aroma compound in food.

  • PDF

이원계 Co-C 공정계 온도 고정점의 특성 (Phase transition features of binary Co-C eutectic temperature fixed-point)

  • 김용규;양인석;감기술
    • 센서학회지
    • /
    • 제14권6호
    • /
    • pp.381-386
    • /
    • 2005
  • A Co-C eutectic cell for thermocouple calibration was manufactured and tested to investigate its phase transition characteristics using Type B thermocouples. It was observed that the freezing plateaus were flatter than those of melting, but the melting points were closer to the true transition temperature than the freezing points. The expanded uncertainty of melting temperature was calculated not to exceed $0.2^{\circ}C$ (k = 2). Based on the observed results, the melting process is recommended for the calibration of thermocouples.

KLAPS를 이용한 한반도 어는비 사례 연구 (Case Studies on Freezing Rain over the Korean Peninsula Using KLAPS)

  • 권희내;변희룡;박창균
    • 대기
    • /
    • 제25권3호
    • /
    • pp.389-405
    • /
    • 2015
  • In this study, the occurrence circumstances of 3 cases (12 Jan 2006, 11 Jan 2008, 22 Feb 2009) when the freezing rain was observed at more than two observatories in a day with more than three times each observatory, were investigated. Following the advanced study about the same cases, we have tried to find more delicate differences in using the Korea Local Analysis and Prediction System (KLAPS; 5 km reanalysis data) that has the smallest grid scale at current situation. As results, three common characteristics are found: (1) Just before the occurrence of the freezing rain, the wind direction was consistently continuous and the wind speed was constant or gradually increased for at least 3 hr more. (2) Surface air temperature (Relative humidity) was respectively $3.08^{\circ}C$ (28.76%), $0.47^{\circ}C$ (50.07%) and $-3.60^{\circ}C$ (71.07%) 3 hr ago to break out the freezing rain. It means the freezing rain occurs in a wide range of atmospheric environments. However, the closer it got to the occurrence time of the freezing rain, the closer the surface air temperature was to $0^{\circ}C$, and the bigger the humidity of the surface air was. (3) The liquid precipitation formed in the upper atmosphere, met a cold advection bellower than 950 hPa level and suspected to be changed to the super-cooled condition.

안정적이고 이방성한 빙결 모델링을 위한 암시적 비압축성 유체와 얼음 입자간의 상호작용 기법 (Stable Anisotropic Freezing Modeling Technique Using the Interaction between IISPH Fluids and Ice Particles)

  • 김종현
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제26권5호
    • /
    • pp.1-13
    • /
    • 2020
  • 본 논문에서는 흐르는 물에 의해 빙결 시뮬레이션 되어 방향성이 있는 얼음 형태를 안정적으로 모델링 할 수 있는 새로운 방법을 제시한다. 제안하는 얼음 모델링 프레임워크는 빙결 시뮬레이션에서 중요한 얼음의 성장 방향에 점성이 있는 유체의 흐름을 고려한다. 물 시뮬레이션 해법은 암시적 비압축성 유체 시뮬레이션에 새로운 점성 기법을 적용한 방법을 이용하고, 얼음의 방향과 글레이즈(Glaze) 효과는 제안하는 비등방성한 빙결 해법을 이용한다. 물 입자가 얼음 입자로 상태변화하는 조건은 습도와 물의 흐름에 따른 새로운 에너지 함수에 따라 계산된다. 습도는 오브젝트 표면의 가상 수막(Virtual water film)으로 근사되며, 유체의 흐름은 얼음의 성장 방향을 가이드하기 위해 우리의 비등방성한 빙결 해법에 통합된다. 결과적으로 점성이 있는 물의 흐름 방향에 따라 글레이즈와 방향성 있는 빙결 시뮬레이션 결과를 안정적으로 보여준다.

FRP 복합체의 동결융해 및 고온.고습 저항성에 관한 실험 연구 (Experimental Study on Freezing-Thawing and Warm-Moisture Resistance of FRP Composites used in Strengthening RC Members)

  • 최기선;유영찬;이한승;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.345-348
    • /
    • 2006
  • FRP composites which are used in strengthening existing structure are usually adhered to the concrete surface, their performance are directly affected by environmental condition such as freezing-thawing and moisture. Accordingly, it is required to evaluate bond durability between FRP composite and concrete as well as FRP materials itself. The durability characteristics of FRP composite for freezing-thawing are evaluated in this study with the variables of concrete strength, type of FRP composite, freezing-thawing conditions and freezing-thawing cycle. In addition, material durability of GFRP sheet for high temperature/high humidity condition are examined in this experimental study.

  • PDF

AI 기반 동파시기 예측을 위한 수도계량기 동파시험장치 개발 (Development of a water meter freeze test device for predicting the freezing time based on AI)

  • 김국일;안상병;김진훈;홍성택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.233-234
    • /
    • 2021
  • 겨울철 한파로 인한 수도계량기의 동파는 수돗물 공급 중지, 유출된 후 결빙에 따른 각종 안전사고 유발 및 복구에 따른 비용 발생 등 여러 가지 불편과 문제를 야기시킨다. 본 연구에서는 수도계량기가 실제 동파가 발생되는 환경과 유사한 시험장치를 개발하여 동파영향인자인 온도, 습도, 유량, 압력, 밸브개도, 펌프 가동상태 등을 변화시켜 반복시험을 수행하고자 한다. 이를 통해 얻어지는 데이터를 기반으로 동파 영향인자 간 상관관계를 AI 기술을 적용해 동파시기를 예측하고자 한다.

  • PDF

수평 실린더 표면의 착상에 대한 실험적 연구 (An Experimental Study of Frost Formation on the Horizontal Cylinder)

  • 백상진;이윤빈;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.240-245
    • /
    • 2000
  • In this study, thickness, density and effective thermal conductivity of frost forming on the horizontal cylinder were measured with various air temperature and humidity. Reynolds number and temperature of cooling surface are controlled 17300 and $-l5^{\circ}C$ respectively. In each case of air temperature $5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C,$ varying absolute humidity, experiments were executed. In measuring frost surface temperature and thickness of frost layer, infrared thermocouples and CCD camera were used. Frost was gathered from cylinder to measure mass of frost layer. Experimental data showed that the thickness and effective thermal conductivity of the frost layer increase with respect to time. Thickness of frost layer increase with humidity increasing, and density of frost layer increase with air temperature rising. Frost growth with air temperature and density of frost layer with humidity are affected by whether dew point is below or above freezing point.

  • PDF

동파방지 발열선용 온도제어기 개발 및 전기에너지 절감 효과 분석 (Development of an Anti-Freezing Heating Cable Temperature Controller and Its Power Saving Effects Analysis)

  • 이기홍;이재진
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.101-106
    • /
    • 2014
  • Although anti-freezing heating cable has been widely installed in most residential boiler pipe, there were excessive energy consumption and fire risk due to inadequate temperature control. In this paper, a new energy saving fire risk-free controller was developed by using microprocessing operation which include detection of not only boiler room temperature but also pipe surface one. Its actual effect has been verified to save more than a half of the energy consumption comparing to conventional controller through temperature and humidity chamber experiment.

석회-시멘트 혼합토의 압축강도 및 내구 특성 (The Compressive Strength and Durability Characteristics of Lime-Cement-Soil Mixtures)

  • 오상은;연규석;김기성;김용성
    • 한국농공학회논문집
    • /
    • 제54권1호
    • /
    • pp.83-91
    • /
    • 2012
  • In this study, the compressive strength characteristics of lime-cement-soil mixtures, composed of lime, soil, and a small amount of cement, were investigated by performing the unconfined compression tests, the freezing and thawing tests, the wetting and drying tests and the permeability tests. The specimens were made by mixing soils with cement and lime. The cement contents were 0, 6, 8 and 10 %, and the lime contents were 2, 4, 5, 10, 15 and 20 % in weight. Each specimen was cured at constant temperature in a humidity room for 3, 7 and 28 days. The compressive strength characteristics of the lime-cement-soil mixtures were then investigated using the unconfined compression tests, freezing and thawing tests and the wetting and drying tests. Based on the test results, a discussion was made on the applicability of the lime-cement-soil mixtures as a construction material.

영덕군 덕산리 얼음골의 냉각 및 하계 결빙현상에 관한 연구 (A Study on Cooling and Freezing During Summer Season in Deoksan-ri Eoreumgol (ice valley) Yeongdeok-gun (South Korea))

  • 이진국;신재열;장윤득
    • 한국지역지리학회지
    • /
    • 제21권3호
    • /
    • pp.608-617
    • /
    • 2015
  • 본 연구는 영덕군 덕산리 얼음골의 발생적 특징을 파악하고 하계 결빙현상의 과정을 규명하기 위해 미기상학적 자료 분석 및 지형 발달 특성을 종합적으로 검토하고 있다. 연구지역의 얼음골은 산지 동사면 애추 지형에서 발달하고 있으며 냉각 및 하계 결빙의 강도는 애추의 형태 및 규모와 밀접한 상관이 있는 것으로 판단된다. 얼음골의 냉각은 동계 산지 정상부로부터 애추 내 암설의 공극을 통해 하단부로 이동하는 냉기류에 의해 이루어지며, 그 결과 애추 내 하단부 암설들을 과냉각시킨다. 냉각된 공기는 안정한 기층을 형성하여 외부의 공기와 순환되지 못하고 애추 지형 하단부에 정체하며 일부 유출 지점에서는 초여름까지 결빙 현상을 발생시키는 것으로 파악된다. 특히 냉기류가 유출될 때 외부 공기의 습도 및 기화열의 발생은 결빙 현상에 중요한 요인이 된다.

  • PDF